exhaust (N)ZL212P V Vacuum pressure gauge Exhaust with silencer Exhaust port 1 25 With vacuum pressure gauge (N)ZL212-G P V Exhaust with silencer Vacuum adapter 1/8 7 With vacuum adapter (N)ZL212-GN P V Vacuum pressure switch Exhaust with silencer With digital vacuum pressure switch (N)ZL212-E P V RESETSET Approx. 500 Section A (L: approx. 2900) 2-4.4 Mounting hole MULTISTAGE EJECTOR 76 52

rn-l2 2Ft30l0 (tRl0El{l r/t [/A 7 6.2 39.6 143.0 124.0 10.4 89.7 t6.0 44.5 I1.2 22.4 ti 0 1,050 fi*fil2xl.5 2n9N tttl(}fnl .5lt 3l 60.5 27.0 t).J t 6.2 8.6 55.0 tL.l 79.5 9.1 lt.l fl8 370 fr/A fl{l6dx2 2t3010 {tR)0H,t2.0M 18 39.6 143.0 124.0 10.4 89.7 t6.0 44.5 I t.2 22.1 l 0 1,080 2 fllflE512 2fil330 0$t3.oil 58 8t.0 59.0 t65.0 139.7 t3.5 103.0 15.4 52-3 t4.l 28.1 till t 1,984 J Illtff,l

PF2A5--1 (With voltage output type) (mm) A B Output specification Sensor unit Display unit (PF2A30/31) Output for display unit only 42 62 Brown 1 2 6 Output for display unit + Analog output Analog output 52 72 4 Main circuit Main circuit 4 8 2 Load + 12 to 24 VDC Switch output White Black 4 3 7 43 2-3.4 Flow direction 3 1 5 Blue Load is an analog input equipment such as a voltmeter.

Effective thread length 32 250 to 1000 35 50 0.042 0 250 to 1000 11 72 75 7 11 80 16 23 58 20 60 80 35 32 63 55 0.074 0 250 to 1000 13 89 78 10 13 90 20 23 61 25 75 95 40 37 80 65 0.074 0 250 to 1000 16 110 80 10 13 95 20 25 63 30 90 116 40 37 100 80 0.074 Bore size (mm) ZZ Y 6.8 to 11.3 WH 335 X 10 P 30 S 1/2 NF 215 NE 24 ND 25 MM 27.7 M M18 x 1.5 LZ 7.5 LX 73 LY 53 LT 88.5 LS 10 LH 275 52

O1 effective thread depth RB RA W 4-O1 T Section a-a Standard type (Through hole type)/RZQB 2-RR 50, 63 Flat washer (Included) 4-HR 2-RR Flat washer (Included) b 2-N 4-O 4-N b Section b-b (mm) Bore size (mm) A B C D E FA FB G H I J K L M N O1 O P Q RA RB RR RH T W Z 100.5 82.5 14 22.4 45 33 12.5 9 M8 x 1.25 60 4.5 17 18 34 5.5 M6 x 1.0 9 Rc1/8 24.5 14 10 5.5 7 4.5 49.5 14 32 110 92 16 28 52

Other tube sizes Tube size Number of (O.D.) connection Part No. 10 6 IN-254-52 12 6 IN-254-53 68

Cable connector (4 wire) Right angle type Cable connector (4 wire) Straight type 50 4-7 Mounting hole 31 SMC PREGULATOR E SMC PREGULATOR E RESET 40 52 ITV2090 ITV2090 SET UNLOCK LOCK 84 100 12.5 M12 x 1 Cable connecting threads 1.6 12 (99) (11) SMC PREGULATOR E ITV2090 Rc 1/4 VAC port OUT 2 G ATM (Atmospheric pressure) OUT (Set pressure) VAC (vacuum pressure) 19 36 Flat bracket P3020114 (

Nylon Urethane M Q L D KCT04-00 KCT06-00 KCT08-00 KCT10-00 KCT12-00 4 6 8 10 12 2.8 2.8 7.6 7.6 13.7 11.1 21.1 19.0 28.3 24.3 18 19 21.5 24 25.5 5.3 6.1 7.1 7.9 8.6 28.6 32.7 39.2 45.5 49.2 10.4 12.8 15.2 18.5 20.9 9 16 24 39 52 Note) D: max. diameter Union Y: KCU Effective orifice(mm 2) Weight (g) Applicable tube O.D. (mm) Part No.

Non-standard motor Standard motor Deflection 100 200 300 400 500 600 700 800 900 1000 36 LTF6EPH 4 to 500 to 390 40 LTF6ENH 8 to 500 to 390 44 LTF8FPL 12 to 1000 to 890 to 710 to 580 to 480 48 LTF8FNL 16 to 890 to 710 to 580 to 480 to 1000 71 34 LTF6EPF 2 to 300 to 230 38 LTF6ENF 6 to 300 to 230 42 LTF8FPH 10 to 500 to 440 to 350 to 290 to 240 46 LTF8FNH 14 to 500 to 440 to 350 to 290 to 240 52

SYJ314 N.C. 52 (Without sub-plate 31) 50 (Without sub-plate 29) Base mounted type (With sub-plate) M5 0.8 1.8 (0.1) SYJ324 N.O.

.: 4, 5/32" (Pitch) P = 10.5 18 1.5 SS5YJ3-32, S32Stations -M5 Station n L1 L2 Station 2 41.5 33.5 Station 20 230.5 222.5 3 52 44 4 62.5 54.5 5 73 65 6 83.5 75.5 7 94 86 8 104.5 96.5 9 115 107 10 125.5 117.5 11 136 128 12 146.5 138.5 13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 SS5YJ3-32, S32Stations -C4 Station n L1 L2 Station 2 42.5 33.5 Station

SS5YJ3-32,S32Station -M5T Stations L1 L2 SS5YJ3-32,S32Station -N3T 3 52 44 6 83.5 75.5 8 104.5 96.5 10 125.5 117.5 20 230.5 222.5 2 41.5 33.5 4 62.5 54.5 5 73 65 7 94 86 9 115 107 11 136 128 12 146.5 138.5 13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 Stations L1 L2 3 53 44 6 84.5 75.5 8 105.5 96.5 10 126.5 117.5 20 231.5 222.5 2 42.5 33.5 4 63.5

.: 4, 5/32" A A 5 5 (Pitch) P=10.5 15.5 M5 x 0.8 (A port) (Pitch) P=10.5 15.5 Station n L1 L2 3 52 44 Station 20 230.5 222.5 6 83.5 75.5 8 104.5 96.5 10 125.5 117.5 Station 2 41.5 33.5 4 62.5 54.5 5 73 65 7 94 86 9 115 107 11 136 128 12 146.5 138.5 13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 12 Series SYJ300 Type 20R Manifold: Top Ported (External

EXH. outlet Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) Triangle mark indicator position Approx. 10 D side U side Station 1 2 3 4 5 6 7 8 n C10: R(EXH) port For top ports C10: P(SUP) port 4 A 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A R 62 41.5 (58) 39.5 P B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 25.5 1 21 44.5 63.5 P = 17.5 2n-C4,C6,C8 A, B port Dimensions Formulae L1 = 17.5n + 52

* VDW13-*G-* n-M5 x 0.8 (OUT port) 61 26.5 19.6 13 1.5 7.7 P = 17.5 8.1 4-M3 x 0.5 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes. (16.3) 11.5 7.7 7.7 11.5 5 22.5 40 7.5 L dimensions n (stations) Dimensions 3 4 6 8 2 9 5 7 10 52.5 L1 70 105 140 35 157.5 87.5 122.5 175 62.5 L2 80 115 150 45 167.5 97.5 132.5 185 69.5 L3 87 122 157 52

connector (Y) 300 90 MAX.10 86 (Lead wire length) 87 83 Pg.7 Indicator light Applicable cord O.D. 3.5 to 7 61 Cover diameter 1.5 Cross sectional area 0.23mm2 90.5 R 3 1 P 83 R 3 1 P M type plug connector (M) 92 (Lead wire length) 80 300 77 Cover diameter 1.5 Cross sectional area 0.23mm2 Indicator light 66 R 3 1 P Dimensions n: Stations (Max. 20 stations) Equation L1=16n+10 L2=16n+20 L n 2 42 52

Lateral vacuum entry, With rotating or non-rotating buffer, Built-in one-touch fitting, Pad diameters from 2mm to 50mm, Flat, ribbed, deep, and bellows pad styles, Four different materials available, Vacuum Pad, with Buffer, VACUUM PAD, ZP, ZP2, ZP3, 52 lb

At the end of the operation of the configuration software and when switching between test mode and monitor mode, the motor is turned off. 52 - 11. Operation 11.1 Return to origin position The Card Motor uses an incremental type sensor (linear encoder) to detect the table position.

Lifting force = Theoretical lifting force / t Theoretical lifting force (Theoretical lifting force = P x S x 0.1) Cup diameter (8 to 32) [N] Cup diameter [mm] 8 10 13 16 20 25 32 S: Cup area [cm2] 0.50 0.79 1.33 2.01 3.14 4.91 8.04 -85 4.2 6.6 11 17 26 41 68 -80 4.0 6.2 10 16 25 39 64 -75 3.7 5.8 10 15 23 36 60 -70 3.5 5.5 9.3 14 22 34 56 Vacuum -65 3.2 5.1 8.6 13 20 31 52 pressure -60 3.0

D 5 3-4 IDH Series 52 5. 1 IDX-OM-W038 . 6 6.1 IDH4-10 IDH4-20 IDHA4-23 IDH6-10 IDH6-20 IDHA6-23 1),2) 100500L/min (ANR) 200800L/min (ANR) 540 0.31.0MPa 1535 (85%) 1530 0.150.85MPa 0.15MPa 400L/min (ANR) 600L/min (ANR) 0.7MPa 35 30 30 3) 10 4) 0.1 0.5 () 5) AC100V AC200V AC230V AC100V AC200V AC230V 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 4.2A 2.1A 2.1A 9.4A 4.8A