The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Easy maintenance, Attaches with SMC's standard interface, Diverge piping

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style piping adapter attachment , Easy maintenance , Detach equipment

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Filter regulator and lubricator unit , Clean looking, modular design , Improved

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style T type spacer , Facilitates the redirection of air flow , Easy

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: Bracket for

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment Valve