The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SV2000 SOLENOID VALVE, 5-PORT. VALVE, SINGLE SUB-PLATE. VALVE. SV2000 NO SIZE RATING. .44092 lb. 2D.
Number of Ports: 2 Port, Piping Direct., Plunger Length: Side Ported Long, Actuator Type: 33 [Push Button (Flat Head)], Suffix: -
Number of Ports: 3 Port, Piping Direct., Plunger Length: Side Ported Long, Actuator Type: 33 [Push Button (Flat Head)], Suffix: -
Model: 33, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: DO (DIN Terminal, w/o Connector, Gasket Included), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
die-casted Painting 26 Magnet 11 Motor cover Synthetic resin 27 Side cover Aluminum alloy Anodized 12 Grommet Synthetic resin 28 Cam follower cap Aluminum alloy Anodized 13 Motor 29 Cam follower 14 Motor end block Aluminum alloy Anodized 30 Cam follower 15 Bearing 31 Eccentric gear Stainless steel 16 Bearing 32 Gear bracket Stainless steel 17 Tension plate Aluminum alloy Anodized 33
Body Needle V seal Lock nut Adjustment handle Insert bushing Nut Collar A 1 2 3 4 5 6 7 8 PFA PCTFE PTFE PVDF PVDF PFA PFA PFA Body class 2 y u y u B Dimensions A (B) (max.S) D H Port A 2 x G SMC (J) SMC C E F K Port B E A B C D E F G H J K S Model 48 60 72 LVN20 LVN30 LVN40 24 30 36 12 18 22 88 110 124 34.5 43 52 6 9 11 4 5 6 14 25 25 20 26 33 18 24 30 2.4 7.5 8.0 940 LQ1/LQ3/LVN/LQHB Series
L1 L2 L3 L4 D1 D2 D3 22 LVW60-25A 32 60 70 81.5 14.5 172 LVW80-32A 72 90 94 20.5 205 38 26 LVW80-40A 83 90 20.5 220 48 31 101 LVW90-50A 120 26 275 60 100 39 136.5 LVW90-65A 120 279 75 135 44 138.5 26 LVW90-80A 304 89 158 140 51 143.5 33 OUT 853 LVW Series Applicable Fluids PVC Quick Drain Valve Material and Fluid Compatibility Check List Compatibility Chemical Material option N Note 2) Ammonium
DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD PE Q S T U W MACM2 X114 68 74 76 10 27.4 12 34 X115 52 6 62 X116 50 4 30 46 60 64 22.5 MACM4 X114 86 90 90 72 78 32.5 50 19 32 20 33
Series IDW Features -40F dew point standard, -100F optional Suitable for global installation 12~24VDC or 100~240VAC Vertical or horizontal mounting Designed for simple service with desiccant canisters Intelligent electronic processor Specifications Inlet flow rate Dimension inch Weight (lbs) Dryer configuration Dryer model Pipe size B C A scfm 17.5 IDW04N 29 4 20 IDW06N 31 6 22 IDW08N 33
M9mWV D-M9mA/M9mAV Hs A Ht B [mm] Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV A B 32 7.5 7 40 6.5 7 45 6.5 7 50 7 6.5 56 7 6.5 63 8 8 67 8 8 80 9 9 85 9 9 100 9 10 Auto switch model Auto switch model D-M9m D-M9mW D-M9mA D-M9mV D-M9mWV D-M9mAV Hs Ht Hs Ht 32 24.5 22.5 30.5 22.5 40 28.5 25.5 34 25.5 45 30.5 27.5 36 27.5 50 33
Dimensions [mm] Model Port size P A (B) (C) (E) (F) (G) H J K L M JSXFAE-06 3/4 74 76 113 54 83 54 25.4 41.3 25.4 18.8 JSXFAE-10 1 94 90 137 82 120 65 33.3 44.4 38.1 31.6 JSXFAE-14 1 1/2 126 117 178 92 170 139 80 51.3 50.7 45 33 7 Pulse Valve Valve for Dust Collector JSXFA Series Dimensions: JSXFAF/Direct Piping Type Port size: Sizes 06, 10 A A A A Pilot port 1/8, 1/4 (Rc, NPT, G) Pilot
removing DIN rail) 187.3 (When locking DIN rail) 152.5 161 170 Mountable on DIN rail (35 mm) 77 17.5 4.5 For body mounting (Screw mounting) L 5.25 12.5 (Pitch) 7.5 5.5 (25) (35) 1.25 L Dimensions [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33
(inch) Connection thread UNF NPT
Nesting exceeded 33 Sub-routine nesting (calling a sub-routine from another sub-routine) exceeds 14 levels. No return destination 34 No return destination found for the RET command operation. Executing FOR 35 A forbidden command is found between FOR and NEXT. No FOR 36 NEXT command was executed without executing FOR command.
Applicable model FGGS FGGL O-ring 1 1 FGF-KT01 FGF-KT02 V-band 2 1 CY-27S O-ring 3 1 FGE-OP007 FGE-OP008 Hexagon plug 4 1 33 FGG Series Dimensions 214 0 3 x 15 For M12 foundation bolt AIR VENT OUT 30 197 DRAIN IN AIR VENT 90 270 G1/8 180 150 ORIENTATION C Dimension required for removal Rp1/4 A B Rc2 IN Rp3/4 DRAIN Rp1/4 190 440 360 Rc2 155 145 OUT (mm) C B A Model FGGSB FGGLB 1180 to 1415
refrigeration Fan motor Compressor for refrigeration Pressure switch Pressure switch Condenser Fan motor Evaporation thermometer Capillary tube 93 C IDFAE Series Dimensions IDFA3E to 15E1 A B A D E Q C F G C M N L P K 4 x 13 In case of IDFA3E IDFA4E to 15E1 Dimensions (mm) B C D E F G K L M N P Q A Model Port size IDFA3E IDFA4E IDFA6E IDFA8E IDFA11E IDFA15E1 15 Rc 3/8 226 410 473 67 125 304 33
Clean Room Specication Dimensions: Ball Screw Drive 11-LEFS16 (72) ( ) +0.025 0 3H9 depth 3 40 Body mounting Note 1) reference plane 4 x M4 x 0.7 thread depth 6.4 24 28 3.5 39.4 ( ) +0.025 0 3H9 depth 3 L Cable length 250 (37) A (Table traveling distance) Note 2) (110) 37 40 (41) [39] 39 [(41)] Stroke (2.4) 7 65 [Origin] Note 4) Origin Note 3) 27 4 [2] 2 [4] 9.2 Motor cable (2 x 5) 46 6 20 33
Fittings & Tubing Air Cylinders Rotary Actuators Lead wire length 300 mm 2-M5 x 0.8 4(A), 2(B) port Direct manual override Indicator light 0.5 0.5 4 (11) 11 2 5.5 0.6 0.6 15 5.3 5.3 13 34 33 25.5 29 6 3 L plug connector (L) 21.5 4 2-3.5 mounting hole 28.5 49 50.5 2-M5 x 0.8 1(P), 3(R) port 3 1 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure
1.08 1.23 1.4 1.56 1.72 1.88 2.04 2.20 2.36 2.52 2.88 2.84 3.00 3.16 3.22 11-LEFG40-S 2.07 2.29 2.51 2.72 2.94 3.15 3.37 3.58 3.80 4.01 4.23 4.44 4.66 4.87 5.09 5.30 5.52 5.73 527 11-LEFG Series Dimensions: Ball Screw Drive 11-LEFG16-S 4 x M4 x 0.7 thread depth 6.4 3H9 (+0.025 0 ) depth 3 24 40 (72) 39.4 28 3.5 3H9 (+0.025 0 ) depth 3 (37) A (Table traveling distance) 36 L 7 7 27 40 40 33
Description Material Voltage D126J45-29 (100 VAC) D126J45-31 (200 VAC) D126J45-33 (240 VAC) D126J45-30 (110 VAC) D126J45-32 (220 VAC) 812PG-DC24V (24 VDC) Part no. AMH Cap Body AME 3 Motor AMF ZFC Operating time 201324 (Nil) 201325 (4) 201326 (6) 201327 (8) 4 Cam Cast steel SF SFD 5 6 NBR KA01323 O-ring Brass, NBR 20137-1A Valve assembly LLB AD AD GD 379