R ZZM 06 06 R Multi-ejecter Common SUP port location Port and silencer location Series ZM Manifold Nil Both sides Number of stations R Right side L Left side B Both sides Right side Left side R L 01 1 station Right or left to the VAC port Right or left to the VAC port 05 5 stations Common EXH port size 10 10 stations (Max.) 04 06 1 2 3 4 Thread type S Silencer for ZZM (ZZM-SA) Nil Rc NPTF
NVEP NVEF 3 1 r T 1 0 3 4 0 T I tffi IFTC I B"dt nowj I Rate rype I I Ports Port Size Code Max. Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
Barb cassette creeps into the direction D and the tube will be clamped at the B clamp portion (5) consisting of barb (3) and case.
B [mm] 11 S coupler KK4P-03MS 35.7 H06 Metric size One-touch fitting 6 KQ2H06-03AS 13 H08 8 KQ2H08-03AS 13 H10 10 KQ2H10-03AS 18.4 H07 Inch size One-touch fitting B B 1/4" KQ2H07-36AS 13.4 H09 5/16" KQ2H09-36AS 13.4 H11 3/8" KQ2H11-36AS 18 With S coupler plug mounted (KK4P-03MS) With One-touch fitting mounted (KQ2H AS) -3- 4.External dimensions Long nozzle(Option) L + 7 Reference dimension
NVEP NVEF 3 1 r T 1 0 3 4 0 T I tffi IFTC I B"dt nowj I Rate rype I I Ports Port Size Code Max. Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.
0 Normally Closed/Single unit Electrical option Nil None Port size S With surge voltage suppressor L With indicator light 02 03 04 Rc 1/4 Rc 3/8 Rc 1/2 With light/surge voltage suppressor Z Refer to the table (1) given below for availability.
Screw tightening torque VO307K: 1.35 to 1.45 Nm V11 : 0.14 to 0.17 Nm Parts for manifold 02 03 04 02 03 04 04 06 10 01 02 10 12 01 02 14 20 Description VEX312VEX322VEX332VEX342VEX350VEX370VEX390Bracket (with bolt and washer) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A Foot bracket (with bolt and washer) VEX1-18-2A VEX3-32-2A Silencer for pilot exhaust port (PE) AN120-M5 AN103-01 AN210-02 Note 1
Model L5 D3 T2 13.7 18.7 16.8 18.7 18.7 20.8 20.8 21.8 34.6 33.9 11.8 39.6 38.9 22.9 28.2 25.2 28.2 28.2 32.6 32.6 34.4 11.6 15.2 12.8 15.2 15.2 18.5 18.5 20.9 38.4 44.7 43.4 46.4 51.3 54.1 64.2 66 14 15.8 18 19.7 20.3 23.1 32 35 65 68 107 110 212 215 6 8 6 8 8 10 10 12 ASP330F-01-06S ASP330F-01-08S ASP430F-02-06S ASP430F-02-08S ASP530F-03-08S ASP530F-03-10S ASP630F-04-10S ASP630F-04-12S
06 0.05 to 0.65 MPa 1 2 2 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 3/4 0.1 to 0.9 MPa 2 02 03 04 03 04 06 1 3 30 Rc 3/8 Rc 1/2 Rc 3/4 4 0.005 to 0.15 MPa 1 1 4 45 1 2 3 4 12 8 4.5 2.5 Without sub-plate Rc 1/4 Rc 3/8 Nil 02 03 JIS Symbol Flow type Flow type Pressure type 2 3 03 04 06 25 Rc 3/8 Rc 1/2 Rc 3/4 4 1 14-9-11 2 Series VEF/VEP Application Example How to Use DIN Terminal Caution Controlling
Analyzer, instrumentation Specifications PVQ10 03: 0.3, 04: 0.4, 06: 0.64, 08: 0.8 Model PVQ30 16: 1.6, 23: 2.3, 40: 4.0 Orifice (mm) Fluid Ambient and fluid temperature Port size Max. operating pressure (MPa) Hysteresis Repeatability Proof pressure Rated voltage Power consumption Coil insulation Air, inert gas 0 to +50oC M5 03: 0.7, 04: 0.45, 06: 0.2, 08: 0.1 Rc 1/8 16: 0.7, 23: 0.35, 40
03 04 06 1/4 3/8 1/2 3/8 1/2 3/4 1 2 3 4 3/8 03 04 06 3 1 30 3/8 0.005 to 0.15MPa 1 4 1/2 4 45 1 3/4 12 8 4.5 2.5 Without sub-plate Nil 02 03 1(P) Symbol Flow type (VEF2) Flow type (VEF3) Pressure type (VEP3) 2 2(A) 1/4 3 3/8 2(A) 2(A) 1(P) 3(R) 1(P) 3(R) 03 04 06 25 3/8 1/2 3/4 1 4 Note) Does not conform to ISO1179-1. 886 Series VEF/VEP Electro-Pneumatic Proportional Valve Application Example
3 Port Air Operated Valve Series VGA342 How to Order VGA342 04 A Passage Port size Thread type 04 1/2 06 3/4 10 1 A B Rc F G N NPT T NPTF Nil Normally closed (N.C.) Normally open (N.O.) Specifications Return mechanism Air + Spring Type of actuation N.C./N.O. (Changeable) Operating type Air operated type JIS Symbol N.C. N.O.
06 0.05 to 0.65 MPa 1 2 2 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 3/4 0.1 to 0.9 MPa 2 02 03 04 03 04 06 3 1 30 Rc 3/8 Rc 1/2 Rc 3/4 4 0.005 to 0.15 MPa 1 4 1 45 1 2 3 4 12 8 4.5 2.5 Without sub-plate Rc 1/4 Rc 3/8 Nil 02 03 JIS Symbol Flow type Flow type Pressure type 2 3 03 04 06 25 Rc 3/8 Rc 1/2 Rc 3/4 4 1 14-9-11 Series VEF/VEP Application Example How to Use DIN Terminal Caution Controlling
AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B
FH150 Series How to Order 0 1 0 02 P 005 FH150 Made to Order Hydraulic filter Nil X0 None (Standard) Micromesh element equipped Port size (Rc) Note) Click here for details 02 03 04 1/4 3/8 1/2 Bracket Nil None With bracket B Differential pressure indication Nominal filtration None Differential pressure indicator Differential pressure indication switch Note) 0 4 5 005 010 020 5 m 10 m 20 m
(.) 9-2 Ball valve Heavy duty auto drain (ADH4000-04) Drain tube (10) IDFA Series 9-1 9 1 IDX-OM-W032 9 L 9-3 (ADH4000-04) IDFA22E 75E-23-L ) 0.151.6MPa N.O.() 3/h(ANR) ) 3m 9-4 1.
6 Body size If more than one option is required, write option part numbers in the order of K, N. 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size (1) 4 6 8 10 12 04 06 08 10 12 Electroless nickel plated (3) Brass PBT PBT/Stainless steel NBR NBR NBR NBR NBR NBR NBR/Stainless steel Electroless nickel plated Elbow type Control method Meter-out Meter-in 0 With One-touch fitting
Port size With One-touch fitting 01 M5 M5 R 1/8 R 1/4 R 3/8 R 1/2 02 03 04 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 167 Series KK Flow Characteristics Air (0 to 1 MPa) Water (0 to 0.4 MPa) KK2 KK2 0.007 0.50 Series KK2 (KK2S-M5M + KK2P-M5M) Series KK2 (KK2S-M5M + KK2P-M5M) 0.45 0.006 0.40 0.005 0.35 Flow rate m3/min (ANR) Flow rate m3/min Flow rate m3/min 0.30 0.004 0.25 0.003 0.20