SMC Corporation of America
Elite Part Number Search
Search Results "SX12F-KG"

Weight*11 kg 45 *1 Use the product in conditions where freezing will not occur.

Weight*11 kg 69 *1 Use the product in conditions where freezing will not occur.

Weight11 kg 69 67 Use the product in conditions where freezing will not occur.

Chapter 8 Control, Inspection and Cleaning 8.4 Stop for a Long Time HRS Series 8-10 HRX-OM-R005 Chapter 9 Documents Chapter 9 Documents 9.1 Specifications List 9.1.1 Product specification Table 9-1 Specifications List [HRS060--20-BJM] Model HRS060-A-20-BJM HRS060-W-20-BJM Cooling method Air-Cooled refrigerated type Water-Cooled refrigerated type Refrigerant R410A (HFC) Quantity of refrigerant kg

m2 kg V m/s 4. 4-1 CE1 4-2 A A B B C COM(OV) D COM(OV) E 12 24V F 0V G CEU5 CEU5 3 +12V +12V 1k A 680 COM +12V +12V 1k B 680 COM +12V DC12V60mA GND F.G. 4-3 (1)CEU5 CE1-R** (2) (3) (4) (5) *(CEU5**-D)EMC CEU5) 5. 5-1 () CE1 14.5mT CE1 15000 18cm 5-2 0.1mm 0.0 0.2 0.1 A B (1)0.8mm (2) sin cos 2 0.8mm (3)1/8 90,0.1mm/ (4)0.1mm 5-3 CE1 A /B 90 A

This matches the controller. (1) LEG32MDGB-30 -4- 1.2 Specification Model LEG25 LEG32 LEG40 Horizonal (30,50 stroke, L=50 or less) Work load 20 45 60 kg*1 Vertical 24 27 27 Max.weight of transferred object[kg] *2 75 100 150 Pushing forceN*3*4*5 126 to 238 156 to 370 266 to 553 Actuator specifications Speedmm/s*5 18 to 250 24 to 200 24 to 150 Max.acceleration/decelerationmm/s2 5,000 Pushing

Product weight [kg] Model Stroke Additional weight with lock Size 50 75 100 150 8 1.06 1.23 0.16 16 1.87 2.26 0.32 25 3.50 4.10 4.90 0.61 -5- 1.3 Construction LESYH*R / LESYH*L R type as shown L type opposite as shown Case of D type Component parts No. Description Material Remarks No.

Product Weight [kg] Stroke [mm] Lock weight Model 50 75 100 150 8 1.06 1.23 0.16 16 2.39 2.78 0.32 25 4.82 5.42 6.22 0.61 -4- How to order Coution The actuator body and controller are sold as a package. If when only the actuator is purchased separately, confirm that the combination of the controller, which you have and the actuator is compatible.

conditions Purge air flow rate L/min(ANR) Inlet air pressure MPa *Note 3 0.7 25 25 Inlet air temperature oC Inlet air saturation temperature oC 1 L/min (ANR) {In the case of inlet air pressure 0.7MPa} 25 Ambient temperature oC Dew point indicator purge air flow rate Regulator construction (about Type V) Relief type Port size 3/8 1/2 3/8 1/2 1/2 1/2 Type M 2.7 3.2 3.3 2.7 3.2 3.3 Mass kg

Roller type/Round Bar Type/Chamfered Type/ Round Bar Type with female thread/ Chamfered Type with female thread Graph(1) Lever Type(With shock absorber) Friction coefficient = 0.1 Graph(2) Mass of transferred object m (kg) Mass of transferred object m (kg) Example 1 Example 2 Transfer speed (m/min) Transfer speed (m/min) Fig. 1 Operating ranges Operating pressure (MPa) Operating pressure

(Note 4) Electrical Specification Voltage V AC230V10% 50Hz (Note 4) Operating current (Note 2) A 4.3 6.9 10.7 Power consumption (Note 2) W 960 1570 2300 Circuit Breaker (Note 3) A 10 20 Condenser Air cooling Refrigerant R407C (HFC) Refrigerant Charge g 45010 76010 55010 74510 Air IN/OUT Connection R1 R11/2 R2 Drain Connection mm 10 Coating Color PanelUrbanwhite 1 BaseUrbangray 2 Weight kg

1.3 1.5/1.5 3.4/3.0 Power consumption (Note 2) W 100V AC,200V AC (50/60Hz) 180/202 208/236 385/440 100V AC 10A Circuit Breaker (Note 3) 200V AC 5A Condenser Plate fin tube type with forced air cooling Refrigerant R134a (HFC) Refrigerant Charge(AC100V/200V) g 2005 2505 2605 Drain Connection Rc3/8 Rc1/2 Rc3/4 Drain Connection 10mm Coating Color Panel: Urbanwhite 1 Base: Urbangray 2 Weight kg

200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21 3.92 7.84 15.68 10 1000 10 2.45 1000 1000 2000 4.90 9.80 19.60 Maximum weight of transferred object [kg

(mm) Model Allowable load(kg) Operating tube Pressure (MPa) 25 REA25 18.5 0.65 32 REA32 30.0 0.65 40 REA40 47.0 0.65 50 REA50 75.0 0.65 63 REA63 115.0 0.65 Table. 12 Intermediate stop 4-1) The cushion effect (smooth start-up, soft stop) exists only before the stroke end in the stroke ranges indicated in the table below.

For setting the gripping force to be at least 20 times the workpiece weight: Required gripping force = 0.17 kg x 20 x 9.8 m/s2 33 N 0 20 40 60 80 Gripping method: External gripping MHK Gripping point L (mm) When MHKL2-20D is selected, the gripping force is determined to be 41N according to the gripping point distance 40 mm and the pressure (0.5 MPa).

Workpiece mass: 0.4 kg 150 Pressure 0.6 MPa Gripping force (N) 0.5 MPa 120 0.4 MPa 90 92 Gripping method: External gripping 0.3 MPa 0.2 MPa 60 Multiples of gripping force by workpiece weight Model 0.1 MPa 10 to 20 times or more MHS2 Number of fingers: 2 30 MHS3 0 10 20 30 40 50 MHSJ3 7 to 13 times or more Gripping point L (mm) MHSH3 Selecting the MHS2-32D.

across flats 7 Effective area: 4.0 mm2 Weight: 3.4 g Effective area: 4.0 mm2 Weight: 1.4 g H/DL L/LL Barb Tee for Soft Tube: MS-5ATHU-3/4/6 KC Weight (g) Effective area (mm2) 1.1 1.4 A1 A2 C D Model KK MS-5ATHU-3 MS-5ATHU-4 3.4 3.6 8 8.8 8.3 8.8 4.5 5 1.6 1.8 KK130 MS-5ATHU-6 2.4 4.2 2.5 7 10.8 10.8 MS-5ATHU-3, -4 DM Width across flats 7 KDM KB KR KA MS-5ATHU-6 Width across flats 7 KQG2 KG

Standard Stroke Cylinder stroke (mm) Model 100 75 50 25 CEP1B12 CEP1B20 2 Series CEP1 Proper Auto Switch Mounting Position Weight Table (without Mounting Brackets / Connector) Unit: kg Refer to p.32 regarding dimensions for the proper auto switch mounting position (stroke end).