47 49 61 63 69 74 73 78 95 100 6 8 6 8 8 10 8 10 8 10 10 12 10 12 10 12 10 R 1/8 23.4 27.4 39.8 45.8 17.6 14 R 1/4 25.4 31.4 39.8 45.8 17.6 12 R 1/8 26.7 30.7 45.3 52.8 24 14 R 1/4 28.7 34.7 45.3 52.8 24 17 R 3/8 30.4 36.7 45.3 52.8 24 17 R 1/4 33.8 39.8 49.6 55.6 30 17 R 3/8 35.5 41.8 49.6 55.6 30 22 R 1/2 37.6 45.8 49.6 55.6 30 Dimension with cover Reference dimension of R thread after
It is also used for switching to the bottom display mode. 734 Series ZSE80/ISE80 2-Color Display Digital Pressure Switch For General Fluids Internal Circuits and Wiring Examples -N NPN (1 output) -P PNP (1 output) -A NPN (2 outputs) Brown DC (+) Brown DC (+) Brown DC (+) Load Main circuit Main circuit Main circuit Load + + + Black OUT 12 to 24 VDC 12 to 24 VDC Load 12 to 24 VDC Black OUT
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
Lock Specifications Clamp Specifications Locking action Spring locking (Exhaust locking) Without shim With shim Clamp stroke 10 mm 0 0.5 Unlocking pressure 0.2 MPa or more 10 mm to 12 mm Lock starting pressure 1 pc.
When equipped with system 2, there are four supply ports, A through D. 32 Air supply ring 24 24 21 Air supply unit body 12 Rc(PT)1/8 Air supply port (plug) 32 IN IN 64 52 (Min. 29) 42 (Min. 29) Supply block unit OUT 342 (Min. 316) + Stroke Air supply ring Air supply unit circuit diagram Rc(PT) 1/8 Air supply port 110 12 2-Rc(PT)1/8 Stroke end air supply port (64) 34.5 32 12 65.5 9
U side 1 2 3 4 5 6 7 8 n 2-C10 R(EXH) port DIN rail clamping screw EXH EXH SMC SMC SMC SMC SMC SMC SMC 2-C10 P(SUP) port R R X B B B B B B B B X P 49 P 31.6 9.5 24.5 16 A A A A A A A A (12) (7.5) 23 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads 41 P = 16 Broken lines and dimensions inside ( ) indicate type [-D] (with
/8 Restrictor (36.5) Clean air filter Note) One-touch fitting 12 103 85 13.2 34.8 3 (41) 111 59 71 80.4 41 59 59 Rc 3/8 (NPT 3/8) 521 3.5 (3.5) Note) This port is unavailable.
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
1263.5 906 960 12 4 800 180 11-LEJS40S-10001323.5 1363.5 1006 1060 14 5 1000 80 11-LEJS40S-12001523.5 1563.5 1206 1260 16 6 1200 80 535 11-LEJS Series AC Servo Motor Clean Room Specication Dimensions: Ball Screw Drive 11-LEJS63 Body mounting reference plane Note 2) 4 x M8 x 1.25 depth 12 6H9 ( ) depth 7 +0.030 0 (172) 122 M4 x 0.7 depth 8 (F.G. terminal) 25 (3.1) 90 129 Motor cable (6) 68
10 14.2 18.5 10 23 21 39.2 15.2 32.1 13.2 6 34 17 34.4 25.2 17.7 15.2 17 8 36 12 18.5 36.4 41.1 36.1 35.6 30.6 27.2 18.5 18.5 10 38 21 18.3 44.5 35.3 13.2 6 R 1/4 63 17 39.3 27.8 15.2 8 65 18.5 41 29.5 21.3 49.9 44.9 44.4 39.4 18.5 10 67 21 43.1 31.5 20.9 12 69 22 44.3 32.8 19 14 23 13.2 6 58 17 39.3 27.8 15.2 8 60 18.5 41 29.5 R 3/8 19.8 47.4 42.4 42.4 37.4 18.5 10 62 21 43.1 31.5 20.9
Check that the power supply voltage is within the range of 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Power saving mode Check if the power saving mode is selected. Reset the function settings. Indicator turns off. 9 Check the power supply wiring.
Straights and Straight Manifolds . . . . . 11 Elbows and L-Tees. . . . . . . . . . . . . . . . 11 Reducing L-Tees . . . . . . . . . . . . . . . . . 11 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Combo Tees (3 branches) . . . . . . . . . . 12 V-Tees . . . . . . . . . . . . . . . . . . . . . . . . . 12 3/8 Male pipe thread-to-tube . . . . . . . . . . 13 Straights . . . . .
No need of power supply for ITV Controller Electro-pneumatic regulator Power supply voltage Output signal Pressure Switch output Power supply voltage Maximum 1 4 to 20 mA 12 VDC Power supply for electro-pneumatic regulator Power supply for electro-pneumatic regulator PWR ERR Minimum Power supply 2 0 to 10 VDC 12 VDC for controller 0 3 4 to 20 mA 24 VDC OFF ON Series ITV Output signal 4 0
-60 3.0 4.7 8.0 12 18 29 48 -55 2.7 4.3 7.3 11 17 27 44 -50 2.5 3.9 6.7 10 15 24 40 -45 2.2 3.5 6.0 9.0 14 22 36 -40 2.0 3.1 5.3 8.0 12 19 32 -12No.
.6 -77No.PS-OMV0008CN-E No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -78No.PS-OMV0008CN-E No.
Incorrect power supply Check if the power supply voltage is in the range 12 to 24 VDC 10%. Supply power in the range 12 to 24 VDC 10%. Check the power supply wiring. Check if the brown and blue wires are connected to DC(+) and DC(-) respectively, and if the wiring is secure. Check and correct the wiring. Incorrect wiring 7 The display is unstable.
V MDSUA3 S9PV S9P 3-wire (PNP) T99V T99 12 V 2-wire Grommet R73 Reed switch 100 V 2-wire Connector R73C MDSUA7 Relay, S79 3-wire (NPN) IC circuit Heavy-duty cord MDSUA20 24 V 5 V, 12 V PLC Solid state switch Grommet S7P 3-wire (PNP) T79 2-wire 12 V Connector T79C Auto switches marked with are made-to-order specifications.
System error (Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 24 VDC 10%. (2) Supply power in the range 12 to 24 VDC 10%. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range.
Refer to page 12 for wiring. Sensor wiring Connect the sensors to the sensor connectors. Pin layout of the sensor connector M12 connector (5 pin, socket) No. Description Even number 0 to 14 Odd number 1 to 15 1 Power supply (24 VDC) 2 (Input) 3 Power supply (0 V) 4.
Reed switch Solid state switch 5 V IC circuit Z76 Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Y es Relay, PLC 24 V 2-wire 100 V, 200 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V 100 V, 200 V 2-wire 3-wire (NPN) 3-wire (PNP) IC circuit Relay, PLC 5 V, 12 V Diagnostic indication