Pad Connection Thread: B5B5 (M5 x 0.8), Orifice Size: 05 (0.5 mm)
Pad Connection Thread: A5 (M5 x 0.8), Orifice Size: 05 (0.5 mm)
Pad Connection Thread: B5 (M5 x 0.8), Orifice Size: 05 (0.5 mm)
Pad Connection Thread: B5W4 (M5 x 0.8 Female Thread, Ø4 One-touch Fitting), Orifice Size: 05 (0.5 mm)
Body Size: 1 (M5 Basis), Style: 3 (Universal), Control Method: 1 (Meter-in), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 2 (Elbow), Control Method: 1 (Meter-in), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 3 (Universal), Control Method: 0 (Meter-out), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 3 (Universal), Control Method: 1 (Meter-in), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 3 (Universal), Control Method: 0 (Meter-out), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 2 (Elbow), Control Method: 1 (Meter-in), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 1 (M5 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Port Size: 10-32UNF, Applicable Tube OD: 05 (3/16"), Sealant: None
Body Size: 100 (M5 Basis), Applicable Tubing: 05 (3/16")
Body Size: 100 (M5 Basis), Applicable Tubing: 05 (3/16")
32 32 32 10 10 1 100 500 400 300 200 1000 1 100 500 1000 400 300 200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph n Graph c 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 100 100 63 63 50 50 Load mass m [kg] Load mass m [kg] 32 32 [Example] 50 50 40 40 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum speed
N 0 16 12 IN313-AB2 Controls up to 32 solenoids and 32 auxiliary inputs. Each input module handles 4 inputs (8 modules maximum). Status LEDs for inputs and outputs Use with Series (N)VFR, (N)VFS, (N)VZS, ISO valves. N 32 32 EX120-SAB1, EX121-SAB1, EX122-SAB1 Controls up to 16 single solenoid valves.
7 25 to 800 45 33.2 32 M6 x 1 M14 x 1.5 56 12 46 23 17 1/4 19 18 12 16 15 30 35 12 18 14 43 40 25 to 800 63 41.7 43 M8 x 1 M16 x 1.5 73 14 51 32 3/8 17 18 9 19 22 20 19 34 37 12 19 47 22 50 25 to 800 75 52.3 60 M12 x 1.25 M20 x 1.5 74 20 57 33 1/2 29 11 32 18 28 30 25 42 9 24 42 53 28 63 25 to 800 90 64.3 60 M12 x 1.25 M27 x 2 80 20 55 33 29 1/2 32 13 36 17 30 32 50 13 39 30 36 68 80 25
/24/8/8 byte 24 24 8 8 Cannot be selected 9 24/24/24/24 byte 24 24 24 24 Cannot be selected 10 32/32/8/8 byte 32 32 8 8 11 32/32/32/32 byte 32 32 32 32 : If you select the "Cannot be selected" method in the above table, all process data are treated as zero and the product generates "process data mapping fault" diagnostics that indicates the amount of process data size exceeds IO-Link master
Note 1) l (Drill through) Cotter pin d D m Dd9 L H B C 3 x 18l 4 x 25l 4 x 35l M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 36 51 72 4 4.5 5 3 4 4 44 60 82 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 -0.040 -0.076 -0.050 -0.093 -0.065 -0.117 Note 1) A cotter