SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-04-M3"

offset 47 46 45 44 43 43 41 40 39 38 37 36 35 34 33 32 Item Flow measurement value (PD) Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item Temperature measurement value (PD) Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Item Reservation Temp.

Applicable bore size (mm) M22 x 1.5 M8 x 1.25 SOR-20 NT-02 20 20 5 13 8 30 26 15 12.5 26 M24 x 1.5 M10 x 1.25 SOR-25 NT-03 25 25/32 6 17 8 36.9 32 19.6 16.5 32 M30 x 1.5 M14 x 1.5 SOR-32 NT-04 32 40 8 22 9 43.9 38 25.4 21.0 38 M33 x 2.0 M18 x 1.5 SOR-40 NT-05 40 50/63 11 27 11 47.3 41 31 26 41 M22 x 1.5 NT-08 80 13 32 37 31 M26 x 1.5 NT-10 100 16 41 47.3 39 1210 High Power Cylinder Series

Port size A B C D E F 28 3/4 31 34 22 143 107 IF320 104 1 37 62 89 28 194 IF321 IF323 104 1 29 39 56 28 161 16-12-9 Series IF3 Flow Rate vs.

Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

1 1 ANB1-12 280 1 4 ANB1-14 450 1 2 610 Construction/Parts/Dimensions Sound absorbing material ANB1-01 to 04 Case (PVF ) End plate JIS Symbol VEX AN Hexagonal flats ANB1-04: PP AMC Cover ANB1-06 to 14 How to Order Sound absorbing material Body Tension bolt End plate B1 03 AN Port size Symbol Connection Port size 1 8 01 1 4 3 8 1 2 3 4 02 03 04 06 10 12 14 Screw-in Hexagonal flats 1 4 1 1

Size (Nominal x Length) Quantity Metric size Inch size TMH-23J TMH-01J M3 x 15 TMH-04J TMH-03J TMH-06J TMH-07J M3 x 20 TMH-06 TMH-07 M4 x 25 TMH-08 TMH-09 TMH-10 M4 x 35 TMH-12 TMH-13 1 Series Holder mounting Select the applicable holder/TMH for each speed controller from the table below.

Binary Output 1 OFF OFF 2 ON OFF 31 point preset output is possible without bank switching, by means of binary system output from a 5 point output terminal.

OFF M3 hexagon screw Tightening torque 0.6 Nm 1 2 0 0 0 IP address 192.168. Y . X : Thread size: M3 x 30 The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

Valve manifold Accessories Side D NOTE (SI unit side) Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.

Solenoid on side B 1 3 5 7 9 17 29 31 No. Designation Description 1 3 5 7 1 1 5 7 Bit No.

Individual grounding should be provided close to the product with a short cable. 28 30 Hexagon socket head cap screw (M3 x 30): 2 pcs. Seal cap: (for M12 connector socket): 1 pc. Pollution degree D Side (SI unit side) NOTE Output No. 1 9 Solenoid on B side 3 5 7 17 29 31 (Note): Y connectors for external power supply are available as accessories.

M3 0.610.63Nm 1) 12mm 10mm -10- 2)L L 4 -11- L (M3X6)L :0.610.63Nm M3 -12- L L M3 (M3X6) :0.610.63Nm 3) :0.610.63Nm 90 -13- 4)DIN L :0.610.63Nm (M3X6)L :0.610.63Nm DIN :0.610.63Nm -14- 5) :0.610.63Nm 3 M3 L DIN -15- 4 4 4 4-3. 3. 3. 3. 1 +24V 2 GND 3 OFF 4 ONOFF OFF 5 0N 6 OFF 7 ON 8 1 ON 9 2 ON ()D ON NPN:GND ONOFF PNP:24V ONOFF NPN:(GND )ONOFF

Max. tightening Maximum screw-in torque depth Model Bolt Depth [mm] (Nm) JMHZ2-8 M3 x 0.5 0.88 6 JMHZ2-12 M3 x 0.5 0.88 6 JMHZ2-16 M4x0.7 2.1 8 JMHZ2-20 M5 x 0.8 4.3 10 Max. tightening Model Bolt torque Nm JMHZ2-8 M2.5x0.45 0.31 JMHZ2-12 M2.5x0.45 0.31 JMHZ2-16 M3 x 0.5 0.59 JMHZ2-20 M4x0.7 1.4 7 - ! Caution 1.

(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED and switch LED display to indicate the status of the SI unit. 2 Switches for setting of node address and operating mode. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.

Screw torque (Nm) depth (mm) MHZJ2-10 M3 x 0.5 0.9 6 MHZJ2-16 M4x0.7 1.6 4.5 MHZJ2-20 M5 x 0.8 3.3 8 MHZJ2-25 M6x1 5.9 10 Max. tightening torque (Nm) Maximum screw-in Model No. Screw depth (mm) MHZJ2-10 M3 x 0.5 0.69 5 MHZJ2-16 M4x0.7 2.1 8 MHZJ2-20 M5 x 0.8 4.3 10 MHZJ2-25 M6x1 7.3 12 Max. tightening Model No.

M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 Model Applicable bolts Max. tightening torque (Nm) MHY2-10D MHY2-16D MHY2-20D MHY2-25D Model Bore(mm) Hole depth (mm) Attachment MHY2-10D MHY2-16D MHY2-20D MHY2-25D 11H9 17H9 21H9 26H9 1.5 1.5 1.5 1.5 +0.043 0 +0.043 0 +0.052 0 +0.052 0 0.88 2.1 4.3 7.4 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 (1) To mount the attachment to the finger, make sure to use a wrench

Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping with a hexagon socket cap screws. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Atmospheric release port To a safe place with no water or dust The tightening torque for bracket mounting screw should be 0.98Nm or less.

M3 hexagon screw Tightening torque 0.6 Nm Terminating resistor Valve manifold : Thread size: M3 x 30 Troubleshooting The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 Model M 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Controller Connectors These are connectors 'all halfpitch type' used for CN1 (control input/output) and CN2 (general purpose input/output).