absorber and stroke adjustment range from 5mm to 15mm 8 12 16 20 25 8 12 16 20 25 4 + Add B Note 1) When only one side of stroke is changed, the quantity needed is the half of the above.
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 VP7 285.5 21 273 No.
Speed Controller Cylinder Solenoid valve Tubing Silencer Max. return speed (mm/s) 10 20 30 6 ASD230FM CJ2 SYJ500 TU0604 1 m AN11001 10 16 Cylinder size 20 ASD330FM CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 32 Values are measured at 0.5 MPa and 20C.
For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Nil N F Rc NPT G With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)
40 50 63 Standard stroke 64 131 27 16 45 49.5 M14 x 1.5 4.5 14 90 14 50, 75, 100, 125, 150, 175, 200, 250, 300 71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64 71 M18 x 1.5 7 18 144 22.5 98.5 200, 300, 500 194 32 20 77 84 M18 x 1.5 7 18 145 21 P M N O T X Z L Q Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc(PT) 1/8 57.5
A master PLC can communicate with up to 16 devices via the RS485 serial interface. (20) Configuration of Step Data The Step Data values can be configured.
-20/40(60 Hz) 20 20 18 Facility water temperature 32C 18 Facility water temperature 32C 16 16 Cooling capacity [kW] Cooling capacity [kW] 14 14 12 12 10 10 8 8 Facility water temperature 40C 6 Facility water temperature 40C 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] 104 Thermo-chiller Standard Type HRS100/150 Series
List of Parameters for each Mode .16 4.1 Parameters common to each mode . 16 4.2 Position control mode . 16 4.3 Speed control mode . 17 4.4 Torque control mode . 17 4.5 Positioning mode . 18 5.
[] 60Hz 50Hz Fig. 9-5 Heating capacity(HRS050-A-20-(BJM)) 9.5.2 HRS050-W-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 5 20 25 32 40 1500 1500 5 20 25 32 40 Heating capacity [W] Heating capacity [W] 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz Fig. 9-6 Heating capacity(HRS050-W-20
No.JXC-OMT0005CN-A DeviceNet (DC24V) // JXCD1 1. . 4 2 . 6 2.1. . 6 2.2. . 7 2.3 . 8 2.4 () . 9 1 . 9 2 . 9 3 . 9 4PLC . 9 5 . 9 6 . 10 7 . 10 8() . 11 9 . 11 3 . 12 3.1. . 12 3.2 . 13 3.3. . 14 3.4. . 16 (1) . 16 (2) . 16 (3) . 17 4 . 18 4.1 Node Address/Data Rate . 18 4.2 . 19 4.3 DeviceNet . 19 1Step Data Class 67h . 19 2IO Class 68h . 20 3IO . 21 4IO . 21 5 . 23 5.1 PWR
Note 1) (1/8), (3/16), 1/4 Lock nut Locks the adjustment knob position.
d" "o* 10ffoll-s t t l 16 E D Il-@ t t l 16 E D Il-@ Flat ribbon cable conneclor: 26 Dins Flal ribbon cable connecior:20 pins Flal ribbon cable connecror: 10 oins . Tie-rod base SS5V .
12 8.5 20 16 11.5 25 3.5 3.5 5 5 10.9 6 6.5 14.3 8.5 085 8.6 086 8.7 087 8.8 088 8.9 089 9.0 090 12.5 17.5 125 12.6 126 12.7 127 12.8 128 12.9 129 13.0 130 175 17.6 176 17.7 177 17.8 178 17.9 179 18.0 180 9 6.5 20 13 8.5 20 18 13 27 4 4 5 5.5 11.6 6 7.5 16.4 9.5 095 9.6 096 9.7 097 9.8 098 9.9 099 10.0 100 13.5 19.5 135 13.6 136 13.7 137 13.8 138 13.9 139 14.0 140 195 19.6 196 19.7 197
Wide Opening Air Gripper Series MHL2 Parallel Style/10, 16, 25, 20, 32, 40 How to Order D 16 MHL 2 1 Y59A S Wide opening Number of auto switches 2 1 n S 2 fingers 2 Numbers of fingers n Bore size 10mm 16mm 20mm 25mm 32mm 40mm 10 16 20 25 32 40 Auto switch Without auto switch (Built-in magnet) Auto switch specifications Action Load voltage Auto switch model no.
Precision Cylinder Series MTS 8, 12, 16, 20, 25, 32, 40 Size 8 newly introduced to Series MTS!
Model Port size A B C D E F G H J K L M N P B B S Y M B O L S NAC1000 M5X0.8 91 84.5 25.5 25 26 25 33 20 4.5 7.5 5 17.5 16 38.5 86.5 NAC2000 18 14 140 125 38 40 56.8 30 50 24 5.5 8.5 5 22 23 50 120.5 NAC3000 38 181 156.5 38 53 60.8 41 64 35 7 11 7 34.2 26 70.5 182 NAC4000 12 238 191.5 41 70 65.5 50 84 40 9 13 7 42.2 33 88 217 NAC5000 34 300 271.5 48 90 75.5 70 105 50 12 16 10 55.2 40
A A1 E1 L1 MM RR1 U1 NZ L CNS 42 56 16 20 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 I-G04 I-G05 Y-G04 Y-G05 +0.5 +0.3 42 56 14 18 22 28 30 40 M14 x 1.5 M18 x 1.5 12 16 14 20 36 41.6 +0.058 0 -0.3 -0.5 +0.058 0 +0.5 +0.3 44 50.6 +0.070 0 Knuckle pin and snap ring are included. -0.3 -0.5 +0.070 0 CLS CLQ MLGP Knuckle Pin (Common with double clevis pin) Rod End Nut RLQ MLU d d Dd9 ML1C C m
L L 2 . 3 . 6 4 . 5 . 6 . 2 2-3. 1 2 Nm mm 16 5 20 M30.5 0.59 6 25 6 8 32 40 M40.7 1.4 8 10 50 63 M50.8 2.8 10 80 M61 4.8 12 100 M81.25 12 16 125 M101.5 24 20 3 P9P11 7 Nm mm MHSH(J)3-32DA,B M30.5 0.6 6 40DA,B M50.8 2.8 10 50DA,B M61 4.8 12 63DA,B M81.25 12 16 80DA,B M101.5 24 20 A J/ / 8 MHS2 Nm mm MHS2-16D M40.7 2.1 8 20D M40.7 2.1 8 25D M40.7 2.1 8 32D M50.8 4.3 10 40D M61 7.3
Item Reference page 16-2-30 Output type Example of internal circuit and wiring 16-2-31 Auto shift function, Anti-chattering function 16-2-32 Measures to be taken when error occurs 16-2-33 16-2-38 15 Series ZSE60F/ISE60 High Precision, Digital Pressure Switch for General Fluids Dimensions Bracket A A 30 20 ZSE ISE 20 PSE 45 Z I SE3 55 4.5 11.5 40 15 PS 4.5 Z I SE1 2 Courtesy of Steven Engineering
MHC2-10D JIS Symbol Double acting How to Order D 20 MHC2 Y59A S Number of auto switches Single acting Angular style air gripper 2 pcs. 1 pc. S Nil Bore size 10 mm 10 Action Auto switch Single acting S 16 mm 16 20 mm 20 25 mm 25 Double acting D Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.