Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
If a different fitting must be used due to unavoidable circumstances, make sure to install a speed controller and use it by adjusting it to 500 mm/s or less. CA2 CS1 C76 C85 Hose nipple CJ-5H-4 (4/For 2.5 tubing) CJ-5H-6 (6/For 4 tubing) C95 Plug mounting style CP95 Width across flats 7 NCM Width across flats 8 Gasket Gasket NCA M5 x 0.8 M5 x 0.8 DMounting Caution 1.
-X 20Data Table (1) 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Inner Cover Holding Screw Tightening Torques [Nm] Tightening torque Model Screw size CYV15 0.3 M3 x 0.5 CYV32 2.45 M6 x 1 Plate Stroke adjustment screw (inner cover) Hexagon wrench Inner cover holding screw direction + direction 8-18-11
Bore sizes: 10, 15, 25 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1200 mm (25 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 50 ~ 500 mm/sec.
Remote high pressure sensor with enhanced durability for liquid or gas; Power supply requirement: 12 to 24 VDC; 1 to 5 V or 4 to 20 mA analog output; Accuracy: ±1% F.S. (500 kPa, 1 MPa); ±2.5% F.S. (2, 5,or 10 MPa); Repeatability: ±0.2% F.S. (500 kPa, 1 MPa); ±0.5% F.S. (2, 5, or 10 MPa); Port sizes: 1/8 or 1/4 Rc male (incl. M5 female)
Bore sizes: 10, 15, 25 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1200 mm (25 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 50 ~ 500 mm/sec.
Remote high pressure sensor with enhanced durability for liquid or gas; Power supply requirement: 12 to 24 VDC; 1 to 5 V or 4 to 20 mA analog output; Accuracy: ±1% F.S. (500 kPa, 1 MPa); ±2.5% F.S. (2, 5,or 10 MPa); Repeatability: ±0.2% F.S. (500 kPa, 1 MPa); ±0.5% F.S. (2, 5, or 10 MPa); Port sizes: 1/8 or 1/4 Rc male (incl. M5 female)
(compound, 500 kPa, 1 MPa); ±2.5% F.S. (2, 5,or 10 MPa); Repeatability: ±0.2% F.S. (compound, 500 kPa, 1 MPa); ±0.5% F.S. (2, 5, or 10 MPa); Port sizes: 1/8 or 1/4 Rc male (incl. M5 female)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 8.11852 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 5.65852 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 8.59802 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 11.39055 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 12.54503 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 12.54503 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 8.59802 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 7.16502 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, RHC ROUND BODY HIGH POWER, ME, 40MM RHC DBL ACT SW CAPABLE, 5.65852 lb
High speed or high load cylinder applications frequently require additional speed and flow control devices to control the stopping of the load. SMC's RHC series features a longer cushion design which is capable of stopping heavy or high speed loads while maintaining the simplicity of a standard air cushion cylinder. This enhanced cushion allows the kinetic distance, which results in the
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?