AHC System Series MA2 How to Order AHC unit AHC unit MA 210 Y M3 N R3 Tool adapter Robot adapter Without robot adapter 8 10 11 14 15 20 Nil S1 R1 R2 R3 R4 R5 Auto hand changer Air gripper for AHC Applicable shaft diameter Transportable mass Transportable mass 3 kg 2 AHC unit Electric specifications Air connection size M3 M3 x 0.5 None N Air gripper for AHC Tool adapter <10/15> MA 210 A M3
5/32 3/8 0.04 0.12 NCRB1_W10-_S 0.55 0.20 0.35 0.02 0.20 25 0.95 1.14 0.59 0.31 0 -0.00015 (0.2) (0.26) M3 NCRB1_W10-_SE 0.33 0.37 -0.0012 -0.00045 5-40UNC 5-40UNC 0.14 10-32UNF M3 3/16 15/32 0.06 0.16 NCRB1_W15-_S 0.71 0.24 0.39 0.02 0.20 25 1.14 1.34 0.79 0.35 0 -0.00015 (0.2) (0.39) (0.24) M3 NCRB1_W15-_SE 0.43 0.39 -0.0016 -0.00045 8-32UNC 8-32UNC 0.18 10-32UNF 15/64 9/16 0.06 0.18 NCRB1
Valve Body Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Holding screw M3 Proper tightening torque (Nm) 0.8 to 1.2 ARBF4050-00-P ARBF4050-00-A Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa M4 1.4 to 2.5 Outlet pressure (MPa) Outlet pressure (MPa) M5 2.8 to 5 How to Calculate the Flow Rate Refer to front matters 44 to 47 for How to Calculate the Flow Rate.
Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Fluid density [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow-rate characteristics are shown in Graph (2).
Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Fluid density [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow-rate characteristics are shown in Graph (2).
THRU 2 HOLES LOCATED AS SHOWN FOR M3 MOUNTING SCREW S or less.
Mounting bolt M3 x 45L M3 x 55L M3 x 60L M5 x 55L M5 x 60L M5 x 65L M5 x 60L M5 x 65L M5 x 70L Mounting bolt M5 x 75L M5 x 80L M5 x 85L M6 x 75L M6 x 80L M6 x 85L RSQB12-10 Note) RSQB16-10 -15 RSQB20-10 -15 -20 RSQB32-10 -15 -20 RSQB40-20 -25 -30 RSQB50-20 -25 -30 7 9 Mounting bolt C D 9 Note) When using the through-hole mounting for a size 12 cylinder, be sure to use the flat washer which
Recommended mounting screw size: M3 without the PD-port / M4 with the PD-port 2) Use the recommended tightening torque (0.54 to 0.66 Nm) to mount the product. Washer included in the accessories (4 pcs.) Mounting hole (4 parts) 11 - Doc. No.
) AC200V () [30mA 10A] 1.25mm 2 (16AWG) 812mm3 () 0.1m 30m (11 ) M3 6.5mm 2 5 2
Connection thread Proper tightening size torque Nm M3 0.40.5 M5,10-32UNF 11.5 Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. If the screw is too shallowly screwed in, it may come loose or air may leak.
Auto Switch Mounting Except for D-P5DWL D-P5DWL Auto switch mounting screw Hexagon socket head cap bolt With SW M3 x 0.5 x 5l M3 x 0.5 x 6l Auto switch Switch mounting bracket With SW, M3 x 0.5 x 14l Round head Phillips screw 8 x 3.3 x t0.8 Flat washer Auto switch Auto switch mounting nut Auto switch mounting nut Tightening torque of auto switch mounting screws should be 0.5 to 0.7Nm.
x 8 M3 137 Series LJ1S Construction LJ1S20 A A Section AA Material Note Parts list Material Note 100W Slide screw No.
LC6D-507AD-Q (Refer to page 306 for details.) 0.05mm Holding plate: MB1 (1 pc.), Phillips countersunk head screw: M3 x 6l (1 pc.) Phillips binding head screw: M3 x 4l (2 pcs.), Toothed lock washer M3 (2 pcs.) Binding band: T18S (1 pc.)
Body ported type M3 0.5 0.9 (0.05) 31 29 SYJ322 N.O. SYJ314 N.C. 52 (Without sub-plate 31) 50 (Without sub-plate 29) Base mounted type (With sub-plate) M5 0.8 1.8 (0.1) SYJ324 N.O.
type ZQ11U-K113.1 17.6 23 32 4-3.5 Mounting hole Lead wire length (approx. 0.3 m) (49.5) Release flow adjusting screw With L type plug connector 33 25 Suction filter Vacuum pressure switch Bracket A (standard) Supply valve Release valve 62.8 Pilot exhaust port (PE port) Note 4) 2-3.2 through Body mounting hole Note 2) S R U N L H L H k Pa MODE S ET HYS Air supply port (P port) Note 4) (M3
Cooled substance total volume V Cooling time h Cooling temperature difference T Facility water temperature Circulating fluid : 60 L : 15 min : 20C (20 K) (70C 50C 20C) : 20C (293.15 K) : Fluorinated fluid Density : 1.74 x 103 kg/m3 Example of conventional measurement units (Reference) 0.06 m3 0.25 h 20C 20C Fluorinated fluid Density : 1.74 x 103 kg/m3 Specific heat C: 1.05 x 103 J/(kgK)
Mount the sensor head using two M3 screws (not supplied with the product). Do not pull the cable connected to the sensor head. Pulling the cable with excessive force may cause sensor head breakage or wire breakage. 2) Installation of sensor amplifier Mount the sensor amplifier using two M3 screws (not supplied with the product). Do not pull the cable connected to the sensor amplifier.
If a socket without check valve is used, the check valve of the plug will not open. 343 KKA Series Flow Rate Characteristics Air Plug: With check valve Socket: With check valve Plug: With check valve Socket: With check valve 50 10 KKA9 Series (KKA9P-12F+KKA9S-12F) 45 9 KKA6 Series (KKA6P-04F+KKA6S-04F) 40 8 Flow rate m3/min (ANR) Flow rate m3/min (ANR) 35 7 30 6 KKA8 Series (KKA8P-10F+KKA8S
Red Power supply terminal block (Terminal screw M3) Indicator light 1021-VV5Q11 Terminal no. SI unit made by OMRON Corp. Mountable for G71-OD16 (Order separately) Flat Ribbon Cable Connector Assembly D side D side Stations Note Assembly part no.
Power supply terminal (M3 terminal screw) 4(A) port side: Orange 2(B) port side: Green (The voltage indication marking is for 24 VDC.) L2 5 (Rail mounting hole pitch 12.5) L1 (Station n) (Station 1) Light/Surge voltage suppressor 5.9 (49.4) ON ON 43.5 7.5 OFF OFF 35.6 Note) For manifold dimensions with elbow fitting, refer to page 392.