mechanism: RSH32-20ll-D SRSH32A, #2 (#2+#5) With cancel cap: RSH32-20ll-C SRSH32A, #3 (#3+#5) With lever detection switch: RSH32-20ll-S SRSH32A, #4 (#4+#5) With locking mechanism + cancel cap: RSH32-20ll-DC SRSH32B, #1 (#1+#5) With locking mechanism + lever detection switch: RSH32-20ll-DS SRSH32B, #2 (#2+#5) With cancel cap + lever detection switch: RSH32-20ll-CS SRSH32B, #3 (#3+#5
Also, when the sealant tape is used, leave approximately 1 thread ridge exposed at the end of the threads. 100 2d D L 1 = Mandrel 5 - 2. Specific Product Precautions (2) (3) Check the model, type and size before installation.
(Body ported type) If gasket is scratched, replace the 2) Damage or displacement of the gasket. gasket Eliminate foreign matter with air blow. 3) Foreign matter caught in the gasket -If gasket is scratched, replace the gasket. seat 1) Valve mounting screw is loose -Tighten the mounting screw. 2. Air leakage from output [2(B),4(A)] port and exhaust [5 (EA),3(EB)] port.
Symbol Nil N T F Thread type Rc NPT NPTF G VCW23-5G-2Q .. 5 sets Valve part no. (Stations 1 to 5) Series 2 3 4 Class 2 Class 3 Class 4 Enter together in order, counting from station 1 on the D side.
The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.
AS ASP ASN AQ ASV How to Order AK D 01 S AS 2 0 0 2 ASS ASR ASF Type adjustable by flat head screwdriver Body size 1 2 3 4 JIS Symbol M5 standard 1/8,1/4 standard 3/8 standard 1/2 standard With seal Note) In case that connecting port is either M5 or 10-32 UNF thread, it is not available with seal. With gasket is provided as standard.
Valve rubber seat is damaged. Replace the check valve assembly. Replace the valve assembly. 2. 2. 3. 3. Foreign materials caught in check valve seat. Valve spring is damaged. Replace the valve spring. 4. 4. 5. Valve adheres to the valve guide. 5. Wash the sliding surface of valve O-ring and grease up. Clog of the element. Replace the element. 1. 1.
1/4 3 3/8 5 3/4 6 1 8 1 1/2 9 2 02 1/4 03 3/8 04 1/2 06 3/4 10 1 14 1 1/2 20 2 T H R E A D T H R E A D 1 Male 2 Female (Only NAMC220, 320, 520 Special Order Only) R(PT)* Remove (N) when ordering N NPT Courtesy of Steven Engineering, Inc. !
stopper) Max. 10.5 (metal stopper) 2.4 Piping port 2-M3 x 0.5 Without magnet and switch rail 2 12 2-M2 x 0.4 depth 2.2 For rail mounting (mm) F Model H J M S Z AA 12 2-M2 x 0.4 depth 3 For magnet mounting MXP65 25 38 33.5 37 5 45 2 35 53 48.5 47 10 60 9.5 MXP6-10 8 Series MXP Dimensions MXP10 2-M3 x 0.5 depth 3 Z 3 With metal stopper 2-M3 x 0.5 depth 5 V K 5 4 G Max. 5.5 Max. 3.5 N 20 M
Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 2 (2) AS121F-M3 AS131F-M3 M3 x 0.5 (2) AS121F-M5 AS131F-M5 M5 x 0.8 AS121F-U10/32 AS131F-U10/32 10-32UNF Tube swivels 360 Universal type permits 360 piping swivel. (2) AS221F-01 AS231F-01 R1/8 AS221F-02 AS231F-02 R1/4 2 size added to applicable tubing sizes Metric size (Release
) r 0 6 l27l 1 2 6 (32\ 1 4 2 136t 1.20 30 5, , 2 4 (6) Millimoters in Parentheses Millimetec in Parenlheses NVFil2so-N024 NVFIrt250-N02-36 F O_F.. 5.07lbs. (2 3 Ks) T T '75 PSIG (5 Kgt/cm2) A H c D tr F u H J K M N o 6 6 8 160 6\ 5 4 6 138 6) 1 5 7 (40) 1 2 2 (31) 0 0 6 (1 5) o 1 2 (3) 0 9 4 23 9) 1 5 7 (40) 1 0 6 (271 1 4 2 (36) 1 2 6 t32\ 1 2 0 30 5) , 2 t (6) A B D E F G H J K M N 6 8
) r 0 6 l27l 1 2 6 (32\ 1 4 2 136t 1.20 30 5, , 2 4 (6) Millimoters in Parentheses Millimetec in Parenlheses NVFil2so-N024 NVFIrt250-N02-36 F O_F.. 5.07lbs. (2 3 Ks) T T '75 PSIG (5 Kgt/cm2) A H c D tr F u H J K M N o 6 6 8 160 6\ 5 4 6 138 6) 1 5 7 (40) 1 2 2 (31) 0 0 6 (1 5) o 1 2 (3) 0 9 4 23 9) 1 5 7 (40) 1 0 6 (271 1 4 2 (36) 1 2 6 t32\ 1 2 0 30 5) , 2 t (6) A B D E F G H J K M N 6 8
LVH Variations LVD LVQ Electrical entry Valve LQ 0 1 0 0 (2" 0 39% " " LVN 2" 39% TI/ TIL " "3 2" PA Model Solenoid coil PAX 3 5 6 ) $ 5 4 ! + PB 7/ VXP2130 Threaded type # 7 8! , :! 7 # , :! 7 Rated voltage 7. -/ VXP214 VXP215 VXP226 VXP227 VXP238 VXP239 Flange type 2 0 2 0 # , 8 3 7// ! -// 8: ! 77/ ! --/ !
Load Load Switch 1 Switch 1 Blue [Black] Blue [Black] Brown [Red] Brown [Red] Switch 2 Switch 2 Blue [Black] Blue [Black] Power supply voltage Residual voltage Leakage current Load impedance Load voltage at OFF = x 2 pcs. x Load voltage at ON = x 2 pcs. = 1mA x 2 pcs. x 3k = 6V = 24V 4V x 2 pcs. = 16V Example: Power supply is 24VDC Voltage decline in switch is 4V Example: Load impedance
B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5. Solid sphere Position of rotational axis: Through the center of diameter r 2 2 r I = m5 27 - Kinetic energy Table 9 shows the allowable kinetic energy of the rotary table.
for mounting attachment) M3 X 0.5 (Finger closing port) Groove position for auto switch mounting (2 positions) Adjustment needle for finger speed 11.6 3 9.4 S 4 6 0 -0.05 4 7 7 Note) For single acting, one port is used as bleed port. 2.3 17.5 M3 X 0.5 (Finger opening port) MHKL2-12l/Long stroke model 9 20 2-M3 X 0.5 thread depth 5 (Mounting thread) 3H9 depth 3 +0.025 0 2-M3 X 0.5 thread
Note 2) Suffix S to the part number, if w/ seal is desired.
M5 AS 1 000 Body size Lock nut option Nil J (3) 1 2 3 4 5 M3, M5 standard Hexagon lock nut Round lock nut 1 8 1 4 , standard standard standard standard 8 3 Note 3) Only for AS1000 2 1 Option H (1) 2 1 High temperature (5 to 80C) Thread type Low temperature (30 to 60C) L (2) Note 1) AS5000 is available as special. AS1000 is not applicable. Note 2) AS1000, AS2000 are not applicable.
The operated load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100VAC. A contact protection box should be used in any of the above cases.
Note 2) Combinations of H and M, R and S, S and T, L and M are not available. Note 3) Option "T" is not available for IDU6D, 8D-4 and -6.