1 Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g) can also be held in the palm of the hand.
PPA101 for vacuum PPA102 for low press. 10 to 100 kPa 0.1 to 1 MPa Rated pressure range 101 to 10 kPa Pressure display 3 digit LCD back light Pressure display discrimination 1/100 1 1 kPa 0.01 MPa 5 mmHg Note) kgf/cm 2 Mini. display units 0.01 0.01 0.1 0.2 inHg 0.1 0.1 1 PSI 0.01 0.01 0.1 bar Error display Over pressure, Memory data error, Change battery sign Peak/bottom display, Backlight
Type L One-touch connection Screw-in connection [L/min(ANR)] 1.
FLOW Hysteresis 1 Hysteresis 1 SET Set point 1 Set point 2 button (UP) button (DOWN) button (SET) ON Item Default settings Model Item Default setting Instantaneous flow PF2A2 series [10L] 1 to 10 L/min type (PF2A510) Connecting the wiring Attaching the sensor connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.
) 2.3 70 10.5 8.5 26 54 50 17 70 18 205 (206) 70 3/8, 1/2 AMJ4000 273 (274) 3.2 90 13 11 35 66 70 23 90 24 284 (285) 90 3/4, 1 AMJ5000 Note) ( ) is the case for metal bowl. 13-13-5
ZFA10 1/8 50 Large filter element surface P.276 30 Adaptable for a manifold application ZFA20 200 1/4 Cartridge type allows element replacement ZFB Unrestricted 360 piping tube mounting on the IN side 4 10 ZFB10 Universal joint type 6, 3/16" , 1/4" 20 Easy installation and removal with One-touch fittings 6, 1/4" 30 Light and compact molded resin parts ZFB20 P.279 30 8 50 Cartridge
Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
Press the DOWN button once to reduce the value by one digit, press and hold to continuously reduce. [ 500] 500 L/min (PF3A801H) [P_1 ]/[P_2 ] Input the set value FLoW [F 1]/[F 2] [ 50] 50 L/min (PF3A801H) [1000] 1000 L/min (PF3A802H) Caution Piping Fit the raised part of the spacer to the recessed part (groove for the raised part) of the product.
Set value Sets the ON or OFF point of the switch output. 50% of rated flow 1 L+ Brown 18 to 30 VDC SET button Hysteresis Setting of hysteresis can prevent chattering. 5% of rated flow 2 N.C.
Light load Motor load Voltage IFW510 1 to 10 20 1 or less N.C.
4 " 3 8 " 1 2 " 3 16 " 1 4 " 3 8 " 1 2 0604 0805 0806 1065 1075 A07 A11 A13 B05 B07 B11 B13 Metric size G Green C Note) Clear Inch size Note) Polyurethane only. 13-10-6
Part No. 07 1/4" 09 5/16" Part no.
1 !0 !5 !6 !4 !7 !8 Component Parts No. Description Note 1 Ionizer ZVB20: 1 unit, ZVB40: 2 units, With diffusion nozzle 2 Additional air blow nozzle ZVB20: 2 pcs., ZVB40: 4 pcs., Nozzle diameter: 1.0 No.
Coil voltage 1 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others When requiring AC specification of grommet or special voltage, consult SMC. 2 3 4 5 6 9 2.10-5 VQZ100/200/300 Body Ported Standard Specifications Seal Metal seal Rubber seal Air, Inert gas Fluid 0.7MPa (High pressure style: 1.0MPa) 0.7MPa Max.operating pressure 0.1MPa 0.15MPa
Applicable load Lead wire length (m) Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Grommet Reed auto switch Yes 12 V 24 V 2-wire Note 1) Lead wire length symbols: 0.5 m Nil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
500Vp-p, Pulse width: 1S, Start up: 1nS Withstand voltage Between external terminal batch and case: 1000VAC 50/60Hz for 1 min.
SealKir 25, 30, 35, 40. 45, 50, 75, 100 25 30,35,4A, 45,50.75, tOD 25, 30, 35.40, 45, 50, 75, 100 .Ho{ to make interrediaie slroke rtrmediale stroke berwen 50-l0o (5s,60,65 ...) are obtained throlgh the use ol spaceB (5. 10, 1s,20mm) (Example) CDQBPSo-55 oMr S[4C would install a 20mrn width spacer in rire cDQ2Bp 50 750M. ll lool brackel is required, order 2 pcs/cylindef.
Set value Sets the ON or OFF point of the switch output. 50 oC Excessive accumulated flow Rc(NPT)1/2 28 to 30 Nm Setting the ON and OFF points of the switch output. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
INPUT CHARACTERISTICS Conforming to UL 508 Input voltage 24 VDC + EN 60730-1 20% 15% EN 61010-1 Input current 5mA EN 50081-1 Pull-in voltage at logic state 1 18V EN 50082-1 Drop-out voltage at logic state 0 4V EN 50082-2 Response time 15ms Programming method Function blocks Status indicator YES on LCD screen Program size 64 function blocks or 1,500 bytes RELAY OUTPUT CHARACTERISTICS Program
Fix switches outside 1 to 4 mm further than the values in the above table (if 1 switch is used, make sure that it turns ON and OFF properly; if 2 switches are used, make sure that both switches turn ON). Note 3) ( ) in column W is the dimensions of D-A93.