As a guide, adjust it within the smaller range than the values of L2 dimension in Table (3). Turning the bottom screw is not allowed. Piston rod Table (2) MXP6 MXP10/12/16 L2 L2 L2 (mm) 10 (One side only) 10 (One side only) 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Damage is not allowed. 3.
Positioning driver Allowable Moment (Nm) Allowable dynamic moment Allowable static moment Pitching Rolling Yawing LXS Model 15.7 15.7 7.84 Load movement direction a = 1000 2000 a Mep a = 2000 a = 3000 L1 (mm) L2 (mm) L3 (mm) Pitching Rolling Yawing m : Transfer load (kg) L : Overhang to work piece center of gravity (mm) a : Work piece acceleration (mm/sec) Me: Dynamic moment 1000 m L1 5 10
Note 5) Each value is a guide. Use such value to select a motor capacity.
L12 A WH G H ZY + 2 x Stroke L12 VD L2 Cushion valve G WH + Stroke A H + Stroke L8 + Stroke With rod boot at one end d e f l h h + L8 + H + 2 x Stroke With rod boot at both ends d d e e L8 + Stroke h f l l + Stroke f 2 x h + L8 + 2 x Stroke h + Stroke A B d11 D EE PL RT L12 KK SW G BG L8 VD WA WB WH ZY Bore size (mm) Stroke range (mm) L2 L9 32 40 50 63 80 100 125 190 26 7 4 4 94 16 32 10
) Side Support Side support A MY-S25A 9.5 5 35 5.5 8 50 77 91 Side support B MY-S25B M6 x 1 35 77 8 50 91 A set of side supports consists of a left support and a right support.
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
of arm section) L1 = 50 [mm] L2 = 40 [mm] a m L2 Item Load factor n Note zLoad mass 1 = m/mmax = 0.5/5 = 0.1 Investigate m.
M1E m x g FE M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420 mm/s in Graph (3).
CY1F CY1F M1E m x g FE CYP M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420 mm/s in Graph (3). M3 M3E m x g FE L2 DFrom above, n = 1 + 2 + 3A + 3B = 0.1 + 0.082 + 0.35 + 0.28 = 0.812 From n = 0.812 1, it is applicable.
M1E m x g FE M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420 mm/s in Graph (3).
The rod is manufactured to precise tolerances, so even a slight deformation may cause a malfunction and damage.
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -