P/N 3/8 B5 x 2 3/8 B5 x 3 3/8 B5 x 4 3/8 B3 x 2 #2 1/2 Barb P/N 3/8 B2 1/2 x 2 3/8 B2 1/2 x 3 3/8 B2 1/2 x 4 3/8 B2 1/2 x 5 3/8 B2 1/2 x 6 3/8 B2 1/2 x 7 #3 Barb P/N 3/8 B3 x 2 3/8 B3 x 3 3/8 B3 x 4 3/8 B3 x 5 3/8 B3 x 6 #4 Barb P/N 3/8 B4 x 2 3/8 B4 x 3 3/8 B4 x 4 3/8 B4 x 5 Thread Size 1 Barb # (Size) Quantity of Barbs Part Numbering Example 52 Available with #1, #2, #2
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ZSE ISE ON YES OFF P-1 P-2 GPM gal (US) PSE Real-time flow rate GPM = gal (US)/min P Window comparator mode H: Hysteresis Z I SE3 Note) Fixed SI unit (l/min, l, m3 or m3 x 10) will be set for the type without the unit switching function.
Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?
Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?
Please refer to P.125. Specifications AP3200 Normally closed (N.C.)
switch Reed switch 12 V Relay PLC Yes Grommet 24 V 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12 V 5 V A96V A96 IC circuit Yes Grommet A93V A90V A93 A90 100 V Relay PLC 12 V 24 V 2-wire No 100 V or less IC circuit Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked
P PD1 PD1 PD3 Supply valve Regulator Air filter 9. When using the male thread mounting type product, do not loosen the bottom nut shown in the figure below. (The bottom nut is intended to secure the connection between the bracket for the adapter connection and the male thread.) PD3 Circuit without release valve (Usage example of vacuum connection) V V PD2 PD2 Supply valve EXH.
(N) and (P+) (N-)) of the main circuit converter is displayed. 0 to 900 V 19 Station No.
XSA1 4.5 6 XSA2 7 8 XSA3 10.5 11.5 Reverse pressure potential 0.5 MPa(G)*1 Weight New New 18% *1 XSA1-12 (Refer to the Specifications on page 3.) 0.5 kg 0.41 kg lighter *1 Rated voltage *1 XSA2-2 32 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC 24 V, 12 V Applications Photovoltaic cell manufacturing Semiconductor manufacturing LCD manufacturing New New Female thread type (Rc,
Lead wire length (m) Load voltage 5 (Z) Applicable load Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 1 (M) 3 (L) AC DC 12 V In-line A93 M9N M9B Reed auto switch 24 V 2-wire 100 V 12 V Relay, PLC Grommet Yes 3-wire (NPN) Solid state auto switch 24 V Relay, PLC Grommet Yes 12 V 2-wire Lead wire length symbols
Oil proof heavy duty vinyl cord: 2.7, 0.5m D-F9N(V), D-F9P(V): 0.18mm x 3 cores (Brown, Black, Blue [Red, White, Black]) D-F9B(V): 0.15mm x 2 cores (Brown, Blue [Red, Black]) Note) Refer to page 7 for auto switch common specifications and lead wire length. Internal circuits Weights (g) D-F9N(V) D-F9N(V) D-F9P(V) D-F9B(V) Auto switch part no.
A96V A96 IC circuit 5 V Yes A72 A72H 12 V 200 V 100 V Grommet A93V A90V A93 A90 IC circuit 5 V,12 V 12 V 100 V or less No Relay, PLC 2-wire A73C A80C A79W 24 V Yes No Connector IC circuit 5 V,12 V 24 V or less Grommet Yes Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ
: P IDG-EL75LA IDG100LA,100SA Option : P IDG-EL100LA -5- 4.
Operating pressure P (MPa) P 0.7 MPa 4. Speed V (mm/s) V 500 mm/s Guideline for Selection of Bearing Type Bearing type Required conditions Impact load and vibration load are added. Change in load is large. Long life span is required. Slide bearing Selection of bearing type High accuracy (Little rattle is allowed.)
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
(example: If the Pressure switch with output impedance of 1 k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5 (V) x 1 (M)/(1 (k) + 1 (M)) 4.995 (V), and there is an error of approximate 0.005 V). Output impedance Operation mode Either hysteresis mode or window comparator mode can be selected.
Auto switch model Lead wire length (m) 0.5 (Nil) 3 (L) 5 (Z) Load voltage Indicator light Applicable load Perpendicular In-line Special function Type Electrical entry Wiring (Output) AC DC 100 V A90 A90V 5 V, 12 V 100 V or less IC circuit No Relay PLC 24 V Reed switch Solid state switch 2-wire A93 A93V 12 V Grommet Yes A96 A96V IC circuit 5 V 3-wire (NPN equiv.)
kPa -0.1001.000 MPa / 10.0-105.0 kPa -105.0105.0 kPa -0.1051.050 MPa / 0.1 kPa 0.001 MPa 500 kPa 1.5 MPa DC1224 V10 (p-p)10 35 mA 2F.S. 1digit(253 ) 0.2F.S.1 digit 2.5F.S.(253 ) 1F.S. 2%F.S.(25) NPN PNP 2 80 mA (NPN) 28 V () 1 V (80 mA ) 1 1.5 ms (20,100,500,1000,2000,5000 ms ) 0 2 15 V 0.65 V 1 k 420 mA 2.420 mA 12 V 300 24 V 600 50 0.4 V 5 ms -75No.PS-OMU0002CN-D
A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F P5DW 200 V A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV Grommet Yes 100 V 12 V Relay, PLC 2-wire 24 V Connector 12 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 2-wire 12 V Connector Relay, PLC Yes 24 V 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic output
P P P R R R R DIN DIN DIN DIN ISO#:EN ISO#:EN ISO#:EN ISO#:EN-175301 175301 175301 175301-803 803 803 803C C C C( ( ( ( DIN DIN DIN DIN 43650C)( 43650C)( 43650C)( 43650C)( 8mm) 8mm) 8mm) 8mm) DIN IP65() () 90 :3.57 ()JIS.C3306 0.5mm 2 3 1(p)3R2R5R1 3(R2 3(R2 3(R2 3(R2 R) R) R) R) 5(R1) 5(R1) 5(R1) 5(R1) 1 1 1 1 P P P P) ) ) ) VQZ100/1000 KQ2H06-M5 AN120-M5 KJS04-M5 VQZ200/2000 KQ2S06