Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F

Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F

Valve; w/Stop Valve, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F

Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/o Flow Adj.

Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/o Flow Adj.

Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/o Flow Adj.

Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.

0.4MPa 0.5MPa 0.6MPa 40 20 20 40 0.6MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Holding point L mm Holding point L mm Holding point L mm Holding point L mm Note) Distance to the holding point L of single acting type is shorten by spring return.

Recommended pneumatic circuit Air slide table W 2.Be sure to use meter-out speed control valves. 3.To release end lock manually (be sure that air pressure is released), push down the lock piston pin with a screw driver, and slide the table in the release direction.

Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

20 '10 456 180 s t5 24 1m 1 U 220 1 1 0 18 6.0 World Wide QS\E Support... North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc. (Cleveland) 2305 East Aurora Rd., Unit A-3 Twinsburg, OH 44087 Tel: (330) 963-2727 FAX: (330) 963-2730 SMC Pneumatics Inc.

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 , , 1 4 3 8 40 40 50 50 55 55 65 85 , AMH250 1 2 3 8 1 2 , AMH350 3 4 1 2 3 4 , AMH450 1 1 1 1 AMH550 AMH650 3 4 1 2 , , 14-20-34 6 Micro Mist Separator with Prefilter Series AMH AMH850 Dimensions Accessory D: With auto-drain (N.O.) for AMD850 female thread Option T: With element service indicator Courtesy of Steven Engineering