SMC Corporation of America
Elite Part Number Search
Search Results "HRR024-AN-20-M"

5P) 74 36 59 5 32 8 Operating port M5 x 0.8 33 34 33 (Y) (Y) Operating direction (B) 6H9 +0.030 depth 5.5 0 39 125 (Plug: M-5P) Operating direction (A) 10.5 (B) 9.5 10 20 20 18 A 10.5 43 31 23 21.5 Z A 3 Cross section AA 4-M6 x 1 thread depth 12 3 x H G Bottom through-hole 5.1 H 7 depth 5.5 6H9 +0.030 0 F E 6H9 +0.030 depth 5.5 0 (mm) Model Z E F G H MXW16-75 270 83 112 71.5 45 MXW16-100

3 Only for use with M(D)LUB25 Release piston seal NBR M(D)LUB40, 50 Lead-bronze casting !

Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: NPN; Temp

.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)

.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)

(Mounting position: Horizontal) W 1000 500 400 Allowable lateral load W (N) 300 Allowable kinetic energy 200 Piston speed 200 180 200 100 180 Piston speed Allowable kinetic energy 20 to 400mm/s 12.4J 50 40 30 (m1 + m2) V Kinetic energy E (J) = 2 m1: Weight of moving cylinder parts kg m2: Load weight kg V: Piston speed m/s 20 10 0 20 40 60 80 100 120 140 160 180 200 220 260 240 280 300 Kinetic

Our pressure switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 3. Do not use in an environment where static electricity can cause problems, otherwise system failure or malfunction may result. 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling.

dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2

160 176 125 165 M 8 160 115 4 12 11 142 95 19 18 67 190 210 135 96 200 M10 42 194 35 J K L U I O T GR N S W P GL GQ M Q R V Bore size (mm) 20 25 32 40 93 60 5.5 80 35 16 4 25 26 50 M5 x 0.8 4 50 14 53 105 M6 x 1 112 103 70 9 95 40 20 7 32 31 60 M5 x 0.8 7 60 14 63 125 M8 x 1.25 132 104 70 9 95 40 20 7 32 38 60 Rc 1/8 Rc 1/8 7 60 13 63 125 M8 x 1.25 132 115 82.5 11 115 45 25 8 38 47 70 8

160 176 125 165 M 8 160 115 4 11 12 142 95 18 19 96 42 35 67 190 210 135 200 M10 194 P GL GQ GR I J K L M N O Q R S T U V W Bore size (mm) 20 25 32 40 93 60 5.5 80 M5 x 0.8 4 4 35 50 25 14 26 16 53 50 105 M6 x 1 112 103 70 9 95 M5 x 0.8 7 7 40 60 32 14 31 20 63 60 125 M8 x 1.25 132 104 70 9 95 Rc 1/8 Rc 1/8 7 7 40 60 32 13 38 20 63 60 125 M8 x 1.25 132 115 82.5 11 115 8 8 45 75 38 14 47

Copper-free 104 to 107 Surface resistance 15-3-20 2 Antistatic One-touch Fittings Series KA Male Connector: KAH H (width across flats) Effective area (mm 2) Connection thread M thread Uni thread Applicable tubing O.D.

Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.

Port size Rc Model M V M V M V M V M V M V M V M V M V M V M V M V M V M V M V M V M V M V M V M V VX2110 VX2112 N.C. N.O. VX2120 VX2122 N.C. N.O. VX2220 VX2 N.C. N.O. VX2320 VX2322 N.C. N.O. VX2130 VX2132 N.C. N.O. VX2230 VX2232 N.C. N.O. VX2330 VX2332 N.C. N.O. VX2240 VX2242 N.C. N.O. VX2340 VX2342 N.C. N.C.

EK M : Kinetic energy (J) : Load weight (kg) + Weight of movable part (kg) : Piston speed (m/s) EK= 2 M 2 Allowable Kinetic Energy When Locking 40 1.19 {12.1} 32 0.67 {6.8} 25 0.42 {4.3} 20 0.26 {2.7} Bore size (mm) Piston speed (m/s) J {kgf cm} Stopping Accuracy (Not including tolerance of control system.)

H G I J K L A B C D E F M R +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 9 9 16 16 +0.027 0 +0.027 0 +0.027 0 +0.027 0 36 38 55 55 16 18 22 22 9 9 12 15 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 16 30 30 36 44 M4 10 10 13 13 10

14.5 17 L 29 32 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 1 4 3 8 4.1-71 Direct Air Operated 3 Port Valve/Manifold Series VVXA31/32 For Air, Gas, Vacuum and Oil Compatible with a wide variety of fluids.

Load weight kg Load weight kg m s m s Type of impact s m 1 2 m2 Kinetic energy E1 Thrust energy E2 Fs Fs + mgs Fs mgs Absorbed energy E E1 + E2 Symbols : Speed of impacting object (m/s) m: Mass of impacting object (kg) F: Cylinder thrust (N) g: Gravitational acceleration (9.8 m/s2) s: Shock absorber stroke (m) Note) The speed of the impacting object is measured at the time of impact

Applicable load Lead wire length (m) Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Grommet Reed auto switch Yes 12 V 24 V 2-wire Note 1) Lead wire length symbols: 0.5 m Nil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ