3 2 Chapter 4 Maintenance 4 1 Daily inspection . 4 1 4 2 Periodical Maintenance . 4 1 4 2 1 Cleaning of ventilation grille (suction grille) . 4 1 4 2 2 Service parts . 4 1 4 2 3 Cleaning of auto drain strainer . 4 2 4 2 4 Replacement of bowl assembly . 4 2 Chapter 5 Troubleshooting . 5 1 5 1 Cause and countermeasure of errors . 5 1 Table of Contents 1 Air Dryer Table of Contents Chapter 6

Table (3) Rated Voltage Electrical Option Rated voltage Solenoid valve model (Port size) Orifice symbol (diameter) 1 (2 mm) 2 (3 mm) 3 (4.5 mm) 4 (6 mm) 5 (8 mm) 6 (10 mm) Voltage L (With light) Voltage symbol 5 6 24 VDC 12 VDC VXE21 Model VXE22 VXE23 01 (1/8) Port symbol (Port size) 02 (1/4) 03 (3/8) 04 (1/2) 02 (1/4) 03 (3/8) 04 (1/2) 02 (1/4) Table (4) Bracket Part No.

Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. 4.

Positioning Mode: Minimum actuator travel distance of 1[m]. 28 - Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/LEYG25D LEY32/LEYG32 LEY32D/LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para. No Initial value Recommended value Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3.

YES No Electric actuator PWR LED turns OFF Refer to Failure 1 ALM LED turns ON red Refer to Failure 2 Unable to communicate with electric actuator (JXC-W2A-C) Refer to Failure 3 The electric actuator does not operate correctly. Refer to Failure 4 Please contact SMC 62 - Problem Problem Investigation method No.

A signal type for contact output signal 4 to 6 can be selected by the customer. Refer to Table 2.4-3 Signal type for contact output signals 4 to 6. (1) (2) (3) Setting of contact output signal 4 to 6 Selection of signal type Table 2.4-2 Setting of contact output signal 4 to 6 No.

Connector no. 1 2 3 4 Wire core color Air tubing For PSE300 (ZS-28-C) Brown (DC(+)) Not connected Blue (DC(-)) Black (OUT: 1 to 5 V) Resin pipe Part-A 1 2 3 4 Controller Handling Warning 1 2 3 4 1. Do not drop, bump, or apply excessive impact (100 m/s2) while handling.

[V] 100 kPa 100 kPa 100kPa to 100 kPa 1 MPa 0 0 to 1 MPa For positive pressure 500 kPa 0 0 to 500 kPa C D Range Rated differential pressure range 1 4 For low differential pressure 0 to 2 kPa 2 kPa 0 A C B D Pressure Differential pressure Pressure Differential pressure A C B D 16-3-37 6 Series PSE300 Internal Circuit PSE300 NPN open collector output (2 outputs), Max. 30 V or 80 mA, residual

Higher-level device (PLC, etc.) side Electric actuator (power supply connector) side Each wire conductor size AWG22 Number of core wires 4 Connector specification M12, 4-pin socket, A code (Normal key) Termin Pin No.

Pin arrangement 1 2 Solid state switch Standard part no. 3 4 4 3 3 For the applicable auto switch model, refer to the table below.

Pin arrangement 1 2 Solid state switch Standard part no. 3 4 4 3 3 For the applicable auto switch model, refer to the table below.

Pin arrangement 1 2 Solid state switch Standard part no. 3 4 4 3 3 For the applicable auto switch model, refer to the table below.

A signal type for contact output signal 4 to 6 can be selected by the customer. Refer to Table 2.4-3 Signal type for contact output signal 4 to 6. (1) (2) (3) Setting for contact output signal 4 to 6 Selection of signal type Table 2.4-2 Setting for output signal 4 to 6 No.

Branch Branch N.C. 1 N.C. 2 1 1 1 1 SD+ 3 2 2 2 2 SD4 3 3 3 3 N.C. 5 4 4 4 4 N.C. 6 N.C. 7 1 2 3 4 1 2 3 4 N.C. 8 Shield Controller CN4 Controller CN4 Description Pin No. Description Pin No. EMG+ 1 EMG+ 1 EMG2 EMG2 SD+ 3 SD+ 3 SD4 SD4 EN_SW+ 5 EN_SW+ 5 ON 6 ON 6 DC24V 7 DC24V 7 GND 8 GND 8 Shield Shield 30 - 9.

Pin arrangement 1 2 Solid state switch Standard part no. 3 4 4 3 3 For the applicable auto switch model, refer to the table below.

Oil port size Rc RS H A (mm) Model Air port size Rc Oil port size Rc A B C DA DB DL H NL P QB QL S T W RZQ CCT639.5 11 0 30 86 3 28 45 53 88 86 64 88 104 3/4 3/8 MI W S CCT1007 13 2 32 120 5 33 65 61 123 116 92 125 139 1 1/2 CCT1607 20 2 46 185 0 29 93 60 183 180 144 185 202.5 1 1/4 3/4 CEP1 L Dimension CE1 (mm) 800 700 600 500 400 300 200 100 50 Effective oil level stroke (mm) CE2 CCT63603.5

ML 4 x OA through 4 x OB counterbore depth OL L (OL) 4 x NN through 2 x P (Plug) U X PW VA PE R H T 2 x P D GC GB S Q 2 x P (Plug) GA JC PD GD FB C + Stroke FA G K J A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN 80 (56 x 2) 25, 50, 100 150, 200 85.5 62 25 19.5 4 69 28.5 20.5 25 22 202 34.5 15.5 34.5 50 M12 x 1.75 30 M10 x 1.5 100 (71 x 2) 94.5 66

Oil port size Rc RS H A (mm) Model Air port size Rc Oil port size Rc A B C DA DB DL H NL P QB QL S T W RZQ CCT633/8 3/4 104 88 64 86 88 53 45 28 3 86 30 0 11 9.5 MI W S CCT1001/2 1 139 125 92 116 123 61 65 33 5 120 32 2 13 7 CCT1603/4 1 1/4 202.5 185 144 180 183 60 93 29 0 185 46 2 20 7 CEP1 L Dimension CE1 (mm) 800 700 600 500 400 300 200 100 50 Effective oil level stroke (mm) CE2 CCT63603.5

Date Signature (creator) Date Signature (test engineer) 44 No.EX##-OMY0011-A Table C-4 Commissioning and Parameterisation Checklist for commissioning and parameterization of the module Device type/equipment identification Version: HW/FW Date Creator Test engineer Remark No.

AV 00 1 G 20 02 F C AV AU Manual override AF Nil: Non-locking push type (Flush) B: Locking type (Tool required) C: Locking type (Lever) Soft start-up valve AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body size IR 20 30 40 50 1/4 3/8 1/2 3/4, 1 VEX AMR Light