G1/2 (44) 31.5 T A B IN OUT M 2 x P Port size (D) L K I F J (mm) Electrical entry M Model Grommet Grommet (with surge C37, Port size P A B C E F I J K L D voltage suppressor) DIN terminal Aluminum body type Stainless steel body T U T T 1/4, 3/8 1/2 88 (93.5) 22.5 30 U U V 22 27 55.5 (61) 27 42 (47.5) 24 30 50 20 4.5 5 11 13 37.5 42.5 25 25 30 47.5 (53) 3 A VXD2 64.5 52.5 Model Mounting bracket
Check the angle of the is unavailable in excess of 30/+30 degrees on both ends of the actuator. feedback lever in Initial 21,22 Adjustment, and securely adjust the angle to 30/+30degrees or less. The angle of the feedback lever -The standard positioner stroke is is less than 10 degree or 30 degree or larger from 10 to 30 degrees. Use it within 10 to 30 degrees. 5 -Others.
Type Optical linear encoder (incremental) Resolution [ m] 30 1.25 30 1.25 30 1.25 5 1.25 Sensor Origin position signal None Provided None Provided None Provided Provided Pushing speed [mm/s] 6 Pushing operation Set value of force Note 1) Note 2) Note 3) 1 to 5 1 to 4.8 1 to 3.9 1 to 2 Positioning resolution [ m] 30 1.25 30 1.25 30 1.25 5 1.25 Positioning operation Positioning repeatability
This system Your system Communication data TEMP PV 30 TEMP PV TEMP PV 30 External communication 30 TEMP SP 30 Discharge temp: OFFSET 1 31 dissipation: Heat 1 Circulating fluid temp. in your system: 30 Figure 8-9 When MODE3 is selected HRZ Series 8.4 Offset Function 8-21 HRX-OM-I051 Chapter 8 Appendix 8.5 BAND/READY function Sets BAND to TEMP SP value, and notifies TEMP PV value reaches
24 33 5.5 12 3.5 29 Note) 1/81/4 1/43/8 1/43/8 AC25B-B 1/8 110.2 115.1 28 30 55.1 35 27.5 0 41 35 7 14 4 41 AC30B-B 1/8 110.2 115.1 30.7 30 55.1 35 29.4 3.5 41 35 7 14 4 41 AC40B-B 1/8 145.2 147.1 35.8 38.4 72.6 40 33.8 3.5 50 40 9 18 5 48 1/43/81/2 AC40B-06-B 1/8 155.2 149.1 35.8 38.4 77.6 40 33.8 3 50 40 9 18 5 48 3/4 AC50B-B 1/8 186.2 220.1 43 93.1 30 43.3 3.2 70 50 11 20 6 60 3
MM M 4.5 (2 locations) M4 x 0.7 (4 locations) (Special cap bolt) FX FZ Arm 5.5 FV (mm) Rod Flange M MM Model Rod state 10 mm Clamp stroke 20 mm 30 mm 10 mm Clamp stroke 20 mm 30 mm Head Flange DModel (mm) Retracted Extended Retracted Extended 23 40.5 26 43.5 33 60.5 36 63.5 17 34.5 17 34.5 43 80.5 46 83.5 27 54.5 27 54.5 37 74.5 37 74.5 MKF12-Z FV FX FZ 25 30 45 45 55 55 MKG12-Z MKG16-Z -
50.5 Y61-04 1/2 15 30 50.5 Courtesy of Steven Engineering, Inc. !
For 30 type, common external pilot (on manifold side).
Vinyl chloride piping tube (30 A) ZS-40-U30 30 A Vinyl chloride piping tube 1 pc. 25 A Holding plate ZS-40-U25-A 1 pc., With two hexagon socket head cap screws of M5 x 80. 30 A Holding plate ZS-40-U30-A 1 pc., With two hexagon socket head cap screws of M5 x 65. : Accuracy may vary by 1 to 2%, if vinyl chloride piping tube is replaced. -13No.PF-OMM0005-N Summary of Product parts Body 1 DC(
Cam Lever(-01) 30" 2.29o.71 45. 0.98 (0.3) ffiffiffi CHANGING PUSH BUTTONS One-WayCam Lever(-02) 30" 2 29(O.71 45" 0.98 (0.3) Plunqer(-05) 0.65 (0.2) Roller Plunoer. Inllne {{6) 30' 0.98 (0.3) Roller Plunoer.
25 M10 x 1.25 26 22 19.5 13 10 17 10 9 19 10 45 6 37.5 5.5 10.5 8 30 D32 M10 x 1.25 26 22 19.5 13 12 17 10 9 19 11 45 6 46.5 5.5 10.5 10 30 40 M14 x 1.5 32 24 21 16 14 22 15 10 30 12.5 50 8 56.2 7 13.5 12 39 -X NA NN P RR N S U Z ZZ Bore (mm) 20 M20 x 1.5 1/8 9 146 14 217 226 20 30 Individual -X 25 M26 x 1.5 1/8 9 146 14 221 230 20 34.5 32 M26 x 1.5 1/8 9 159 14 234 243 22 42.5 40 M32 x
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating No-load voltage (V peak) 5.0 0 to 20 [V] 100 Over 20 [V] to 30 [V] Peak voltage value 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
, 40, 50 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 40, 50, 75, 100 Made to Order (For details, refer to pages 1420 and 1470.)
ms to 32.00 ms (in 3.00-ms units) 30 30 3.50 ms 3.50 ms to 32.00 ms (in 3.50-ms units) 30 30 4.00 ms 4.00 ms to 32.00 ms (in 4.00-ms units) 30 30 Note: Communications retry stations can be connected as long as the total number of connected stations, including the retry stations, is within the connectable max. number of stations.
Specifications LAT3-10 Stroke 10 mm, Resolution 30 m LAT3-20 Stroke 20 mm, Resolution 30 m Card Motor 8 options LAT3-30 Stroke 30 mm, Resolution 30 m (Refer to the table Product LAT3M-50 Stroke 50 mm, Resolution 5 m Number on the right) LAT3F-10 Stroke 10 mm, Resolution 1.25 m LAT3F-20 Stroke 20 mm, Resolution 1.25 m LAT3F-30 Stroke 30 mm, Resolution 1.25 m LAT3F-50 Stroke 50 mm, Resolution
sides n = 2, 3, 4 n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 2, 4, 6, 8 (n 2) 2 100 + 100 Same side 100 + 100 (n 2) n = 4, 6, 8 n = 2, 3, 4 1 pc. 75 90 80 10 Different sides 35 75 90 80 Same side 55 75 90 80 90 + 30 (n 2) 35 + 30 (n 2) 75 + 30 (n 2) 80 + 30 (n 2) Different sides D-A44 n = 2, 3, 4 n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 2, 4, 6, 8 55 + 50 (n 2) 75 + 50 (n 2) 80 + 50 (n
Cam Lever(-01) 30" 2.29o.71 45. 0.98 (0.3) ffiffiffi CHANGING PUSH BUTTONS One-WayCam Lever(-02) 30" 2 29(O.71 45" 0.98 (0.3) Plunqer(-05) 0.65 (0.2) Roller Plunoer. Inllne {{6) 30' 0.98 (0.3) Roller Plunoer.
35C 200 200 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] HECR008-A Circulating fluid: Tap water Circulating fluid: Ethylene glycol 20% 2500 2500 Ambient temperature 15C 2000 2000 Cooling capacity [W] Cooling capacity [W] 1500 1500 1000 1000 Ambient temperature 25C Ambient temperature 25C Ambient temperature 35C 500
30 HRLE090-m-20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) M5 R5.5-5 4 cores x 5.5 mm2 30 (4 cores x AWG10) Including grounding cable HRLE090-m-40 3-phase 380 to 415 VAC (50/60 Hz) 3-phase 460 to 480 VAC (60 Hz) M8 R5.5-8 20 An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are