SMC Corporation of America
Elite Part Number Search
Search Results "ASV110F-M3-04"

OFF M3 hexagon screw Tightening torque 0.6 Nm 1 2 0 0 0 IP address 192.168. Y . X : Thread size: M3 x 30 The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

Valve manifold Accessories Side D NOTE (SI unit side) Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.

Otherwise malfunction can result, causing an accident. : Thread size: M3 x 30 Node ID setting No.1 Reserved Technical documentation giving detailed specification information can be found on the SMC website (URL http://www.smcworld.com). The following instructions must be followed during maintenance: Turn off the power supply.

Check that the M3 hexagon socket head cap screws have been tightened to the specified torque. If these items are not adhered to, it may lead to damage to the unit or intrusion of liquid or dust into the units.

Part number Description Remarks ZS-28-A Power and output lead wire and connector Length: 2 m ZS-28-B Bracket Mounting screw (M3 x 5 L) 2 pcs. ZS-28-C-1 Sensor connector 1 pc. ZS-27-C Panel mount adapter Mounting screw (M3 x 8 L) 2 pcs. ZS-27-D Panel mount adapter + Front protective cover Mounting screw (M3 x 8 L) 2 pcs.

Tightening torque: 0.61 to 0.65 Nm IZT43-BL1 / L-type bracket M3 screw 2) Angle adjustment bracket For mounting, fix the bracket using M3x4 screws with the specified tightening torque. Tightening torque: 0.61 to 0.65 Nm IZT43-BL2 / Angle adjustment bracket M3screw 3) Installation of the nozzle Fix the bracket to the specified position using M3 screws. Refer to "6.

M3 0.610.63Nm 1) 12mm 10mm -10- 2)L L 4 -11- L (M3X6)L :0.610.63Nm M3 -12- L L M3 (M3X6) :0.610.63Nm 3) :0.610.63Nm 90 -13- 4)DIN L :0.610.63Nm (M3X6)L :0.610.63Nm DIN :0.610.63Nm -14- 5) :0.610.63Nm 3 M3 L DIN -15- 4 4 4 4-3. 3. 3. 3. 1 +24V 2 GND 3 OFF 4 ONOFF OFF 5 0N 6 OFF 7 ON 8 1 ON 9 2 ON ()D ON NPN:GND ONOFF PNP:24V ONOFF NPN:(GND )ONOFF

Max. tightening Maximum screw-in torque depth Model Bolt Depth [mm] (Nm) JMHZ2-8 M3 x 0.5 0.88 6 JMHZ2-12 M3 x 0.5 0.88 6 JMHZ2-16 M4x0.7 2.1 8 JMHZ2-20 M5 x 0.8 4.3 10 Max. tightening Model Bolt torque Nm JMHZ2-8 M2.5x0.45 0.31 JMHZ2-12 M2.5x0.45 0.31 JMHZ2-16 M3 x 0.5 0.59 JMHZ2-20 M4x0.7 1.4 7 - ! Caution 1.

Model Screw Max. tightening Maximum screw-in depth (L mm) torque (Nm) MHZ2-10 M3 x 0.5 0.9 6 MHZ2-16 M4x0.7 1.6 4.5 MHZ2-20 M5 x 0.8 3.3 8 L L MHZ2-25 M6x1 5.9 10 MHZ2-32 M6x1 5.9 10 MHZ2-40 M8 x 1.25 13.7 13 Model Screw Max. tightening torque (Nm) Maximum screw-in depth (L mm) MHZ2-10 M3 x 0.5 0.69 5 MHZ2-16 M4x0.7 2.1 8 MHZ2-20 M5 x 0.8 4.3 10 MHZ2-25 M6x1 7.3 12 MHZ2-32 M6x1 7.9 13 MHZ2

(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED and switch LED display to indicate the status of the SI unit. 2 Switches for setting of node address and operating mode. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.

Screw torque (Nm) depth (mm) MHZJ2-10 M3 x 0.5 0.9 6 MHZJ2-16 M4x0.7 1.6 4.5 MHZJ2-20 M5 x 0.8 3.3 8 MHZJ2-25 M6x1 5.9 10 Max. tightening torque (Nm) Maximum screw-in Model No. Screw depth (mm) MHZJ2-10 M3 x 0.5 0.69 5 MHZJ2-16 M4x0.7 2.1 8 MHZJ2-20 M5 x 0.8 4.3 10 MHZJ2-25 M6x1 7.3 12 Max. tightening Model No.

with Va) M2=Wx L1=15x0.05=0.725Nm M2 0.75 Load factor a2= = =0.375 M2max 2 Dynamic load M3=WexL2x 1 =52.5x0.05x 1 =0.88Nm 3 3 M3 0.88 Load factor a3= = =0.25 M3max 3.5 M1max=12Nm (Checked with V=1.4xVa) 1 1 M1=WexL1x =52.5x0.05x =0.88Nm 3 3 M1 0.88 Load factor a4= = =

M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 Model Applicable bolts Max. tightening torque (Nm) MHY2-10D MHY2-16D MHY2-20D MHY2-25D Model Bore(mm) Hole depth (mm) Attachment MHY2-10D MHY2-16D MHY2-20D MHY2-25D 11H9 17H9 21H9 26H9 1.5 1.5 1.5 1.5 +0.043 0 +0.043 0 +0.052 0 +0.052 0 0.88 2.1 4.3 7.4 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 (1) To mount the attachment to the finger, make sure to use a wrench

. : MH-G04 (30 g) 706 MHY2 Series 180 Angular Type Air Gripper Cam Type Dimensions MHY2-10D Pin hole positioning 30 9 9 2 x M3 x 0.5 thread depth 4 4 (Thread for mounting attachment) 4 x M3 x 0.5 through (Mounting thread) 3H9+ 0.025 0 depth 3 6 0.005 0.025 4 4 x M3 x 0.5 thread depth 6 3 6 (Mounting thread) 2 x 3.4 through 2 x M3 x 0.5 depth 6 12 (Mounting hole) (Mounting thread) (Limted

Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping with a hexagon socket cap screws. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Atmospheric release port To a safe place with no water or dust The tightening torque for bracket mounting screw should be 0.98Nm or less.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 48 5 11 56 VXA 1 6 VN 1 8 5 M5 M5 LVC 2 (OUT) port M5, 1/8 1 (IN) port M5, 1/8 1 (IN) port 2 (OUT) port LVA 15 LVH 2-M2.5 x 0.45 2-M3 x 0.5 thread depth 5 LVD Thread depth 3.5 VDW31 LVQ 36 (27.6) LQ 300 Lead wire LVN 40 30 SMC SMC 1 1 TI/ TIL AC

x 0.5 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes. (16.3) 11.5 7.7 7.7 11.5 5 22.5 40 7.5 L dimensions n (stations) Dimensions 3 4 6 8 2 9 5 7 10 52.5 L1 70 105 140 35 157.5 87.5 122.5 175 62.5 L2 80 115 150 45 167.5 97.5 132.5 185 69.5 L3 87 122 157 52 174.5 104.5 139.5 192 3 stns. x 1 2 stns. x 2 3 stns. x 2 2 stns. + 3 stns

Bracket B Bracket A Bracket D Mounting screw M4 x 5L Mounting screw M3 x 5L The tightening torque for bracket mounting screw should be 0.5 to 0.7 Nm for M3 and 1.4 to 1.6 Nm for M4. Set Pressure Range and Rated Pressure Range Caution Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting.

Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping. The switch can be installed horizontally depending on the installation location. PSE IS Mounting screw M3 x 5L Mounting screw M3 x 5L ISG ZSM The tightening torque for bracket mounting screw should be 0.98 Nm or less.

The RS-232C can be used to send the table position to a PLC or PC or to set the Multi-counter. 24 x M3 x 0.5 35.5 (DIN rail mounting) A COM COM COM B DC12V GND F.G. R.S. HOLD BANK1 BANK2 MULTI COUNTER:CEU5 UP CEU5 680.2 COUNT PRESET FUNC. LEFT RIGHT 80 4 56 DOWN SEL.