At the maximum stroke Adjustment range Maximum adjustment range Max tightening torque Nm Model Bolt MIW12D-12D M3 x 0.5 0.88 MIS12D-D MIW20D-20D MIS20D-D M5 x 0.8 4.3 23 Series MIW/MIS Specific Product Precautions 2 Be sure to read before handling. Refer to pages 16 through 18 for safety instructions, actuator precautions and auto switch precautions.
22 65 53 40 11.5 M10 X 1.5 22 8 46 8.2 88 18 23 22 65 52.5 40 76.5 11.5 Mounting arms for width across flats When installing the arm for the parallel section at the rod end, the strength of the piston rod might be insufficient depending on the direction in which the arm is installed.
Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B B A W A B stroke 6 5 to 30 3.5 0 17 6.5 13 3.5 2.5(5) 17 4.5 5 to 20 17 13 17 10 25 7.5 3.5 20 16 2.5 7.5 20 1.5 0.5 30 19 15 19 (1) 5 27 23 27 10 22 18 22 15 27 23 27 16 8 4 2 8 2 0 B A 20 22 18 22 Bore (mm) 6 10 16 25 27 23 27 (0.5) 6.9 10 30 27 23 27 8.8 14 13.9 19 Note 1) Negative figures
Applicable heavy-duty cord O.D.6 to 8 Pg9 24 36.5 66.5 57 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 32 40 14 Pilot EXH. 2-5.5 Mounting hole 2-1/4 3 1 Manual override (Non-locking) 9 23 VFN212N--02-D 213 19 23 Applicable heavy-duty cord O.D.6 to 8 Pg9 24 66.5
With front lockR (mm) Bore size (mm) W P WA WB WH 20 M5 x 0.8 16 15 (16) 23 30 25 M5 x 0.8 16 15 (16) 25 30 32 Rc1/8 16 15 (16) 28.5 25 40 Rc1/8 16 15 (16) 33 20 50 Rc1/4 18 17 (18) 40.5 20 63 Rc1/4 18 17 (18) 47.5 20 80 Rc3/8 22 22 60.5 20 100 Rc1/2 22 22 71 20 Dimensions inside ( ) are for long strokes.
Nil Without auto switch Symbol Position detector arms Switch bracket Positioning angle c a b c d 10 11 12 13 14 15 20 23 25 180 Refer to the table below for auto switch part numbers. X X X X X X X X X X X X 90 X b d X X X Table position detector arm X X X X X X a Switch mounting bracket X Cylinder unit/Applicable auto switch types Load voltage Lead wire length (m) Auto switch part no.
(different sides) 25 Auto Switches/Proper Mounting Position for Stroke End Detection D-Z7, Z80 D-Y59, Y69, Y7P D-Y7NW, Y7PW, Y7BW D-Y7BAL A 0 to 1 A B Bore size (mm) B 40 0 23 50 0 23 63 0 32 Auto Switch Mounting Flat head watchmakers screw driver When mounting an auto switch, first hold the switch spacer between your fingers and press it into the groove.
Refer to the Made to Order Specifications on page 23 for the ordering procedure. Hydraulic fluid Compatibility JIS symbol Standard mineral hydraulic fluid Compatible W/O hydraulic fluid Compatible O/W hydraulic fluid Compatible Not compatible Water/Glycol hydraulic fluid Phosphate hydraulic fluid Contact P/A.
Nylon Urethane L1 L2 M 1 4 1 4 3 8 3 8 3 8 KCE04-02 KCE06-02 KCE08-03 KCE10-03 KCE12-03 2.6 32 36 42 79 105 2.6 6.8 16.2 25.6 35.4 M12 1 M14 1 M16 1 M20 1 M22 1 40.5 42.7 49.4 53.9 56.1 14 17 19 24 27 17 17 19 22 24 14.7 14.7 15 14.2 13.7 13 15 17 21 23 18 19 21.5 24 25.5 6.8 13.1 20.4 30.4 Straight: KCH Applicable tube O.D.
L plug connector (L): SYJ34-L-M5 M plug connector (M): SYJ34-M-M5 M8 connector (W0): SYJ34-W0-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.5 [60.7] 48.7 [50.9] 57.6 50.2 43.7 R P R P R P 10 8.6 10 8.6 10 8.6 23 23 23 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to the page 68 for dimensions with connector cable. 6 Series SYJ300
CN1: Power Supply Plug . 22 5.1 Power supply plug specifications . 22 5.2 Electrical wiring specifications . 22 5.3 Power supply plug wiring . 23 6. CN4: Counter Plug . 24 2 - 6.1 Counter plug specifications . 24 6.2 Counter plug wiring . 24 7.
CN1: Power Supply Plug . 22 5.1 Power supply plug specifications . 22 5.2 Electrical wiring specifications . 22 5.3 Power supply plug wiring . 23 6. CN4: Counter Plug . 24 2 - 6.1 Counter plug specifications . 24 6.2 Counter plug wiring . 24 7.
40 AFF,AM,AMD 80D 1 1/2 404 392 394.5 38 170 160 80 23 40 AFF,AM,AMD 90D 1 1/2 2 470 458 460.5 38 170 160 80 23 40 Model Bracket related dimensions H I J K L M N O P AFF,AM,AMD 70D 124 82 48.4 90 18 9 16 10 2.6 AFF,AM,AMD 80D 148 93.5 58.5 110 22 11 20 12 3.2 AFF,AM,AMD 90D 148 93.5 58.5 110 22 11 20 12 3.2 -22- Doc. no.
1 8 User setting lower level detection 0 9 Detection of the upper limit of the ON/OFF cycles 4 16 Detection of US1 power supply voltage drop 9 17 Detection of US2 power supply voltage drop 8 19 Connection failure between units (during operation) 11 System diagnosis 2 20 Connection failure between units (when power is supplied) 12 22 Detection of system error (when power is supplied) 14 23
0.2913 M 0.2950 7.5mm 0.2953 19/64 0.2969 7.6mm 0.2992 N 0.3020 7.7mm 0.3031 7.75mm 0.3051 7.8mm 0.3071 7.9mm 0.3110 5/16 0.3125 8mm 0.3150 O 0.3160 8.1mm 0.3189 8.2mm 0.3228 P 0.3230 8.25mm 0.3248 8.3mm 0.3268 21/64 0.3281 8.4mm 0.3307 Q 0.3320 8.5mm 0.3346 8.6mm 0.3386 R 0.3390 8.7mm 0.3425 11/32 0.3438 8.75mm 0.3445 8.8mm 0.3465 S 0.3480 8.9mm 0.3504 9mm 0.3543 T 0.3580 9.1mm 0.3583 23
Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B A B B W A stroke 6 5 to 30 0 13 3.5 3.5 6.5 17 2.5(5) 17 4.5 5 to 20 13 17 17 10 25 3.5 16 7.5 7.5 2.5 20 1.5 20 0.5 30 15 19 (1) 19 5 23 27 27 10 18 22 22 15 23 27 27 16 4 8 8 2 2 0 A B 20 18 22 22 Bore (mm) 6 10 16 25 23 27 27 (0.5) 10 6.9 30 23 27 27 14 8.8 19 13.9 Note 1) Negative figures
23 to 34.5 0 to 12 12 to 24 24 to 36 0 to 16 16 to 32 32 to 48 Stroke adjustment range by Intermediate fixing spacer (mm) MY1 W Stroke adjustment range is applicable for one side when mounted on a cylinder.
0.2913 M 0.2950 7.5mm 0.2953 19/64 0.2969 7.6mm 0.2992 N 0.3020 7.7mm 0.3031 7.75mm 0.3051 7.8mm 0.3071 7.9mm 0.3110 5/16 0.3125 8mm 0.3150 O 0.3160 8.1mm 0.3189 8.2mm 0.3228 P 0.3230 8.25mm 0.3248 8.3mm 0.3268 21/64 0.3281 8.4mm 0.3307 Q 0.3320 8.5mm 0.3346 8.6mm 0.3386 R 0.3390 8.7mm 0.3425 11/32 0.3438 8.75mm 0.3445 8.8mm 0.3465 S 0.3480 8.9mm 0.3504 9mm 0.3543 T 0.3580 9.1mm 0.3583 23
Adsorption Confirmation 2 Sensor installed close to the pad (No. 2) 1 Sensor installed close to the pad (No. 1) Series PSE54 + PSE200 Series PS1100 16-3-23 16-3-1 16-5-1 Pad adsorption can be confirmed easily. Response delays, caused by piping, will not be a factor due to the close proximity of the sensor to the pad.
is VO307-DZ. 17-4-6 3 Series VNA Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Model Flow characteristics Measured by air Measured by water Note) Weight (kg) Orifice size (mm) Air operated Model Port size Rc Cv Av x 10-5 m2 b External pilot solenoid C [dm3/ (barsec) ] VNA1-6A VNA1-8A 1 8 1 4 10 0.88 1.5 1.9 3.8 4.8 7.5 25 41 51 110 130 210 3.5 5.9 7.9 16 23