Water (1 to 50C), Air, Heated water (80C) Note 3), Low vacuum (133 Paabs) Quick fastener type Fluid Air, Water (1 to 40C) Note 5), Low vacuum (133 Paabs) One-touch fitting type Note 4) Withstand pressure 1.0 MPa Valve specifications Coil specifications 10 to 50C Ambient temperature 1 to 50C (No freezing) Fluid temperature Ambient humidity RH85% Environment Location without corrosive or explosive
Model Note 1) Note 2) Operating system Model Cylinder bore (mm) Gripping force (Effective value) N Opening/Closing stroke (mm) Mass (g) External grip: 88 Internal grip: 139 MHQG2-32D 32 20 1100 Double acting External grip: 158 Internal grip: 247 MHQG2-40D 40 28 1940 MHQG2-32S 69 32 20 1110 Normally open MHQG2-40S 130 40 28 1960 Single acting MHQG2-32C 127 32 20 1110 Normally closed MHQG2-40C
Power Block Specifications Model EX9-PE1 EX Output block (for high-wattage load) Connection block Connection block stations Output block: Max. 8 stations Power supply for output and internal control 22.8 to 26.4 VDC Power supply voltage 20 mA or less Internal power consumption Max. 3.1 A (When using with 3.0 to 3.1 A, the ambient temperature should not exceed 40C, and do not bundle the cable
Viscosity according to ISO Grade 32 Classification of viscosity (cst) (40C) Turbine oil P-32 Idemitsu Kosan Co.,Ltd. Caution Turbine oil 32 Nippon Mitsubishi Oil Corp. Cosmo turbine 32 Cosmo Oil Co.,Ltd. Series LV Kyodo turbine 32 Japan Energy Corp. Turbine oil 32 Kygnus Oil Co. 1.
switch 3 Evaporation thermometer Fan motor Compressor for refrigeration Thermo-dryer Series IDH Standard Specifications Model Specifications IDH4-10 IDH4-20 IDHA4-23 IDH6-10 IDH6-20 IDHA6-23 Compressed air Fluid Air flow capacity Inlet air temperature Inlet air pressure Ambient temperature 3.5 to 17.6 scfm (100 to 500 L/min [ANR]) 7.1 to 28.3 scfm (200 to 800 L/min [ANR]) 41 to 104F (5 to 40C
Store away from direct sunlight at 40C or less. 2. Open the inner package of double packaging in a clean room or other clean environment. R 1/4 12 to 14 R 3/8 22 to 24 R 1/2 28 to 30 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
AV Hysteresis AU 0.05 MPa (5 to 40C) 0.08 MPa (5 to 60C) No freezing Pointer error (5) AF With light: 1a (Normally open) Without light: 1ab (Normally open/ Normally closed) Contact Wiring Indicator light Lead wire (Length: 300 mm) Neon light Light emitting diode (LED) AR AC DC IR Attachment: With cover ring assembly C Part no.: 1305104-4A VEX Weight (kg) 0.12 AMR ITV Circuit Example IC VBA
Clean series fittings 10-KQ2, 10-KF, 10-KDM, 10-KG 10-M, 10-MS, KP, KPQ, KPG Recommended fittings 4 10 15 20 27 35 20 to 60C, Water: 0 to 40C (No freezing) Min. bending radius (mm) Operating temperature Material Cleanliness class (ISO class) Polyurethane Class 3 Caution 1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid.
Filter Regulator Stainless Steel 316 and Special Temperature Environment (40C) Specifications AW30/40-X2622 External parts material: Stainless steel 316 Ambient and fluid temperature: 40 to 80C NACE International Standards compliant The JIS component standards of the external parts and the component measurement results of the certicate for materials are within the ANSI/NACE standards.
(Full span) or less Hysteresis Pressure switch with digital display and self-contained solid state sensor 3% F.S. (5 to 40C), 5% F.S. (5 to 60C) Accuracy AF 12 to 24 VDC (Ripple 10% or less) Voltage Minimum allowable pressure indicator on digital display AR Open collector 30 V, 80 mA or less Output Light turns ON when pressure drops below the set minimum.
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
Specifications IZH10 Model 20.0 kV Rated charge amount range 0.1 kV (1.0 kV to 20.0 kV), 0.01 kV (0 to 0.99 kV) Minimum display unit 50 mm (between sensor part and measured target) Measurement distance 1.5 VDC 2A alkali dry cell battery, 2 pcs (continuous use for 15 hours or more, see Note 2)) Power supply Note 1) 5% F.S. 1 digit Display accuracy IP40 Enclosure Environment Operating: 0 to 40C
ALF ALT Model LMU100 LMU200 Inlet air pressure Oil tank set pressure range Oil Dynamic viscosity of oil (40C) 0.1 to 1.0 MPa 0.05 to 0.2 MPa Turbine oil, Non-water soluble cutting oil (JIS, N1 type) 2 to 200 mm2/s Total capacity: 3000 Effective capacity: 2500 5 to 50C 100 VAC 50/60Hz, 200 VAC 50/60Hz, 24 VDC ALD ALB Oil tank capacity (cm3) Ambient and fluid temperature Solenoid valve voltage
Air, Water Note 1) Fluid 1 MPa Maximum operating pressure 100 kPa Operating vacuum pressure 3 MPa Proof pressure 5 to 60C, For water: 0 to 40C (No freezing) Ambient and fluid temperature Brass parts are all electroless nickle plated. Copper-free (Standard) Note 1) Applicable for general industrial water.
S Couplers Series KK Specifications K M Fluid Air, Water KK2: 100 kPa to 1 MPa KK3: 90 kPa to 1 MPa KK4/6: 0 to 1 MPa H Operating pressure range Note) KK Proof pressure 1.5 MPa Air: 5 to 60C Water: 5 to 40C (No freezing) Series KK2 D Ambient and fluid temperature MS Plating, Sealant Electroless nickel plated (copper-free and fluorine-free application), With male thread sealant LQ Note) Do
Moisture Control Tube Series IDK Specifications IDK02 Model IDK04 Compressed air 0.7 MPa 0 to 40 (No freezing) IDK06 Fluid Max. operating pressure Operating temperature (C) Operating environment 1 Indoors, where product is not exposed to water (0 to 40C, Relative humidity 0 to 75%RH) 20 4 2.5 Min. bending radius 2 (mm) O.D. (mm) I.D.
20 to 40C: FluorinertTM20 to 90C: FluorinertTMFC-3283/GALDEN?HT135FC-40/GALDEN? HT200?20 to 908.0 (at 20C)3.3 (at 20C)?
Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger.
Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger.
0.021250/20Ball screw + Belt (Motor parallel)Sliding bushing (Piston rod)41 to 104F (5 to 40C)90 or less (No condensation)l4236Step motor (Servo/24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 lbs ( 0.15 kg) (Screw mounting), 0.37 lbs (0.17 kg) (DIN rail mounting)Non-magnetizing operation type17.5 (78)524 VDC ?10%