SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20B-V-M5"

1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8 2 Speed Controller with One-touch Fitting Elbow Type (Metal Body) Series AS Flow Rate and Effective Area AS321-03 AS421-04 AS221-01 AS221-02 AS121-M5 Model Tubing O.D. 12 10 10 8 6 8 4, 6 6, 8 Controlled

Common exhaust: VV3P5-41Stations 1-03 (G) (E) (T) (D, Y) (X port) (M5 x 0.8) N.C.

(mm) <M5> <M5> Weight (g) Applicable tubing KCH04-M5 KCH04-01S KCH06-M5 KCH06-01S KCH06-02S KCH08-01S KCH08-02S KCH08-03S KCH10-02S KCH10-03S KCH12-03S KCH12-04S 2.1 2.6 2.4 M5 x 0.8 9.8 30.8 26.1 32.4 37.4 28.9 42.4 45.7 34 50.5 51.5 54.2 41.6 27.3 22.1 28.9 33.4 22.9 38.4 39.7 27.5 44.5 45 47.7 33.6 18 2.1 2.6 2.4 4 8 1 8 10 11.8 12 14 M5 x 0.8 10 16 14 20 27 25 34 43 48 41 Reference dimensions

Effective area (mm2) Weight (g) A L M Model M5, UNF10-32> AKH04-M5 AKH04-01S AKH06-M5 AKH06-01S AKH06-02S AKH08-01S AKH08-02S AKH08-03S AKH10-02S AKH10-03S AKH10-04S AKH12-03S AKH12-04S 8 10 M5 x 0.8 1/8 M5 x 0.8 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 3/8 1/2 24.3 24.6 25.8 26.9 30 31.7 21.2 20.6 22.2 22.9 24 27.7 36 35.5 48.3 40.8 41.3 54 46.5 5 10 4 2.8 12.7 Applicable tubing 2.8 6.5 6.5

Indication Item Output Setting, selection and display CH1 circulating fluid temperature 0C to 100C: 0 to 10 V CH2 circulating fluid Analog temperature 0C to 100C: 0 to 10 V (1) Analog output signal 1 Output 1 CH2 electrical conductivity 0.1 to 50.0 S/cm: 0.02 to 10.0 V CH1 circulating fluid temperature 0C to 100C: 0 to 10 V Analog CH2 circulating fluid temperature 0C to 100C: 0 to 10 V (2

Applicable cylinder series Applicable load Lead wire length (m) Type Load voltage Wiring (Output) 0.5 (Nil) Auto switch model Electrical entry Indicator light Band mounting DC AC 3 (L) 5 (Z) 1 (M) A93 M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC Grommet Reed auto switch Series CKG1 100 V 100 V 200 V Yes 12 V 24 V 2-wire B54 Note 2) Auto switches marked with

Specifications VX P2 Port size Pilot solenoid valve 6A to 25A 32A to 50A VO301-00 Grommet, Conduit, DIN connector Others(Option) VNA11 VNA12 SF4--23 VN P1 P1 Grommet, Grommet terminal Conduit terminal DIN connector External pilot solenoid Electrical entry VQ B A B A AC(50/60Hz) 100V, 200V, Others(Option) 24V, Others(Option) 15% to +10%(rated voltage) Class B or equivalent Coil rated voltage(V)

Rated voltage For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted For AC (50/60 Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Electrical entry 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Indicator light and surge voltage suppressor G: 300 mm lead wire L: With 300 mm lead wire M: With 300 mm lead wire

Wiring top entry Digital pressure switch (Body only ) Lead wire Specifications 0 to 1 MPa Rated pressure range Output 0.1 to 1 MPa Set pressure range NPN open collector 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual output voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC

Wiring top entry Digital pressure switch (Body only ) Lead wire Specifications 0 to 1 MPa Rated pressure range Output 0.1 to 1 MPa Set pressure range NPN open collector 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual output voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC

IDX-OM-W022-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.

for Option V 15 Specification for Option V This option installs the timer operated auto drain.

Otherwise, air leakage may result. 2) After screwing in the fittings, mount the M5 fitting assembly on the manifold base.

T U V . Z A B . (M5:3.0Nm, M6:5.2Nm) Jan o To Uo Vo . Zo Ao Bo . Internal sensor value for alarm = Internal sensor value Fine control value 5.4 Piping Feb P TP UP VP . ZP AP BP . Setting value memory function Ensure that the power source and the power supply of the product is Even if the power is turned off the set values are saved and will be restored at power on. Mar Q TQ UQ VQ .

Rubber seal, spool valve: Grease Connection thread: M5 Mounting First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional 1/6 to 1/4 turn. The reference value for the tightening torque is 1 to 1.5 Nm. 1.

Use N NPT 5 AC100-240V M5,M6 screws (bolts) or equivalent to the fix the product. Note) Only HECR010 with AC200-240V Be sure to correctly tighten all screws to the required torque.

Electrical entry Indicator Lead wire Applicable load 3 (L) 5 (Z) AC DC Parallel code 97 12V Yes 24V 93A Cab tire 12V 100V Relay PLC Grommet 2 wire Parallel code 5V 12V 5V 12V 24 V or less 100 V or less 90 IC circuit No 24V 90A Cab tire * Impossible to mount the auto switch on the clevis and trunnion styles. 1.2-1 Pin Cylinder/Single Acting Spring Return Series CJP 6, 10, 15 How to Order A

Auto switch operating range (mm) Load operating time (ms) V(mm/s) = x 1000 4. Keep wiring as short as possible. Although wire length should not affect switch function, use a wire 100m or shorter. 5. Be careful of the internal voltage drop of the switch.

VER2000 is V type. (Refer to Best Pneumatics Vol. 3 for further information.)

VER2000 is V type. (Refer to Best Pneumatics No. 1 for further information.)