Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3
(D-M9 only) Operation Environment Recommended Tool Description Model Wire stripper D-M9N-SWY * Stripper for a round cable (2.0) can be used for a 2-wire type cable. Warning (1) Never use in an atmosphere with explosive gases. Auto switches are not designed with explosion-proof construction. Never use in an atmosphere containing explosive gas since this may cause a serious explosion.
Weight (g) d T H D1 D2 D3 L1 L2 L3 Model AK 1/8" ASD230F-U10/32-01 8.4 12 10-32 UNF 12.9 8 25.5 22.2 28.6 25.8 29.4 11.7 28.3 10 17.5 7.8 9.6 25 5/32" ASD230F-U10/32-03 9.3 13 ASS 20.7 7.8 16.5 15 3/16" ASD230F-U10/32-05 10-32 UNF 8 9.6 10 11.7 28.3 25.5 28.6 25.8 25 22.2 35.2 23.3 11.4 13.5 13 1/4" ASD230F-U10/32-07 32.6 12 ASR 30 16.5 14 3/16" ASD330F-N01-05S 39.5 39.6 23.9 11.6 34.6 17
Universal Type/Metric Size Applicable tubing O.D. d H D1 (Hexagon width across flats) M L3 A L4 L5 D3 D2 L1 Connecting thread T L2 Uni thread H D1 D2 L1 L2 L5 A Max. Min. Max. Min.
Dimensions are completely the same as D type DIN connector. 3.
E L 4-H Valve mounting hole F Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D E F G H J L Valve model Bracket part no.
Bar length (mm) 300, 380, 620, 780 1100, 1260, 1500 1900, 2300 661 A Series IZS31 Dimensions Feedback sensor/IZS31-DF Amplifier part Head part 2 x 3.4 2 x 3.4 3500 1500 16.6 13 SMC 9 58 25 4.8 10.2 69 15 4.8 23 8 87.5 78 0.5 11 13 6.5 7.8 8.8 8.8 0.5 10.2 10.2 13 60 7.7 7 6 1 50.5 14 Detection hole 10 61 2 x R3.3 Autobalance sensor [High-precision type]/IZS31-DG Amplifier part Head part 2
Inch Size Holder for speed controller Applicable tubing 01 03 07 09 11 13 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" AS1002Fm TMH-01J TMH-03J TMH-07J AS2002Fm AS2052Fm TMH-07 TMH-09 AS3002Fm TMH-10 AS4002Fm TMH-13 Tubing size Applicable model Dimensions Part no.
7.3 D C B A PD port size Metric size: Rc1/8 Inch size: NPT1/8 Supply Port Dimensions [mm] Dimensions [mm] N C4 4.7 C6 4.7 N3 4.7 N7 7.3 A B C D E F ZHP63BM 26 45.8 63 68 12.5 33.8 ZHP80BM 28 57 80 85 18 41.8 ZHP63UM 26 63 66 5 20.3 ZHP80UM 26 80 83 5 20.3 Circuit Adapter Dimensions (by Mounting Style) [mm] G H J K L M ZHPmmmA-mmS 25.7 22.6 5 13 M8 ZHPmmmB-mmS 27.1 21.2 6 17 M10 ZHPmmmC-mmS
The compatibility should be judged by the customer before adopting the product. 790 Vacuum Flow ZH--X185 Series RoHS How to Order B X185 ZH 20 Passage diameter Dust bag Nil D Without dust bag With dust bag (Supplied with product) Hose band attached mm Symbol Bracket Nil B Without bracket With bracket 10 20 30 40 13 21.6 30 42 SP ZCUK Specifications Warning Model ZH10-X185 ZH20-X185 ZH30-
Select the model with air flow capacity exceeding the calculated corrected air flow from data D of the table below.
10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A 142.1 174.1 176.1 247.1 261.1 93.9 122.1 154.1 156.1 227.1 241.1 91.4 28 30 35 34 47 47 2.3 2.3 2.3 2.3 3.2 3.2 40 53 70 70 90 90 8.4 13 12.5 12.5 13 13 5.4 6.5 8.5 8.5 11 11 22 23 26 25 35 35 27 35 52 52 66 66 30 41 50 50 70 70 20 26.7 35.5 35.5 45 47.5 25 35 40 40 30 30 30 38.4 38.4 20 26.7 35.5 35.5
190 13 13 16 16 19 55 66 72 92 98 63 76 76 90 90 7.5 4 4 5 5 63 76 76 90 90 10 10 10 10 10 AMF150 AMF250 1/2 3/8, 1/2 AMF350 3/4 AMF150SAME, #1 AMF250SAME, #2 AMF350SAME, #3 4.6-31 Odor Removal Filter Series AMF Dimensions: AMF450 to AMF850 HAl AT IDl AMG AFF AMl M Dimensions with mounting bracket Model Port size (Nominal size B) A H B C D E F G I 221 J 25 K 10 L 14 N 90 O 55 P 110 Q 50
Weight (g) d T H D1 D2 D3 L1 L2 L3 Model 4 ASD230F-M5-04 9.3 12.9 17.5 29.4 12 25.5 28.6 25.8 28.3 9.6 10 7.8 11.7 M5 X 0.8 8 25 22.2 6 ASD230F-M5-06 11.6 13.7 20.6 32.5 13 34.6 39.6 6 14 ASD330F-01-06S 11.6 13.7 22.9 29 38.5 36.1 31.1 14.2 11.8 10.6 R(PT)1/8 12 32.1 27.1 15.8 33.9 38.9 8 ASD330F-01-08S 15.2 18.5 28.2 31 44.8 6 ASD430F-02-06S 12.8 17 25.2 53 43.5 18 8 36.7 ASD430F-02-08S
pe: NVEF212O, NVEF312O toessureType: ItlVEP3lzO AO.27 " -0.45" I d 6.8 -1 1.smm') Flor Rate T!pe: NVEF213O Florir Rate Typei NVEF214O, NVEF314O Prassurc Type: NVEP814O Supply Exhaust t! UJ I 2-Forled \bBion DIMENSIONS A B c o E F G H J K M P R s T 1.57 (40) 2.52 (64) 2.20 (56) 1.77 (45) 4.80 (1221 1.97 {50} 0.98 (25) 1 . 1 0 (28) 0.51 (13) 4.45 (113) ?
After removing the cause of the alarm or warning, the alarm or warning can be deactivated in any of the methods marked in the alarm / warning deactivation column. "6" of the figure, "B" of the alphabet, and "D" are displayed as follows. 6 B D 7.1 Alarms List This section provides list of alarms.
Auto switch Auto Switch Specifications D-M9(With indicator light) Auto switch model D-M9N D-M9P Electrical entry direction In-line Wiring 3-wire Output NPN type PNP type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage DC28V or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less
Center of gravity .12 4.Product Specifications .13 4-1. Magnet gripper .13 4-2. 3-port solenoid valve .14 4-3. Auto switch .15 5.Operating method or operation .16 5-1Precautions for Design .16 5-2. Installation .17 5-3.TMComponent .20 5-4. Air supply .24 5-5. Piping .24 5-6. Operating environment .25 5-7. Lubrication .25 6. Maintenance or inspection .25 6-1.
0.5 0.5 IZD IZE 11 13 8.8 8.8 6.5 7.8 10.2 10.2 IZH 13 14 60 7 7.7 Detection hole 1 6 10.5 2 x R3.3 10 61 (7.5) Auto balance sensor [High accuracy type]/IZS31-DG 2 x 3.4 2 x 3.4 Amplifier Head 3500 1500 0.2 0.2 20 4.8 6.6 4.8 69 95 23 78 98 14.5 5 8.8 7.8 10.2 10.2 13 Sensor 60 7.7 71 12 1 6 14 2 x Counterbore 6.6, Depth 5.7 (Height of thread bearing surface 8.8) 433 IZS40/41/42 Series Dimensions
m (Filtration efficiency 99%) FGD High precision filtration: 99% or more FGE FGG FGA FGC High accuracy filtration is achieved by using a HEPO1 1element with filtration accuracy of 2, 4, 6 or 13 m (Filtration efficiency 99%).