The pad, mounting nut, and fitting are shipped together but do not come assembled. 136 Flat Type ZP3 Series Compact Type Dimensions/Models Single unit 1.5 to 3.5 w q ZP3 015 U N 3 Model A B q Pad dia.
Do not use compressed air that contains chemicals, organic solvents, salt, or corrosive gases. Do not use compressed gas containing chemicals, organic solvents, salt or corrosive gas. This can cause rust, damage to rubber and resin parts, or malfunction. Liquid surface of drain Discharge drainage until the drainage level reaches the center. 3.
PAuto switch attachment Auto switches can be selected that do not protrude from cylinder body. P2 roller materials available to suit application requirements.
For the auto switch mounting rail, do not remove the pre-equipped rail. Since the mounting thread is drilled through inside a the cylinder, it will result in air leakage. MVGQ For basic style, the port position in a head cover is available either perpendicular to the axis or in-line with the cylinder axis.
Do not immerse the cylinder in water or chemicals. When the cylinder is operated in a condition with water pressure, the fluid leaks into the cylinder in the early stages. In the worst case, the fluid may back flow inside the piping and damage the solenoid valve. Maintenance Warning Mounting 1.
Also, do not attempt to tighten the bumper bolt without using a nut. If the dumper bolt is removed, the piston hits the head cover causing damage to the cylinder. Therefore, do not use a cylinder without a bumper bolt. Furthermore, if the bumper bolt is tightened without a nut, the piston seal is caught in the leveled part, damaging the seal. 3.
Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals, etc. will result in leakage or malfunction. 2.
Do not put hands or fingers between the plate and body. Care should be taken that hands or fingers do not get caught in the space between the cylinder body and the plate when air pressure is applied. 1. Do not scratch or dent the sliding parts of the piston rod and guide rods. Damage to seals may cause air leaks or faulty operation. 2.
Do not move the cover upward inadvertently during end plate installation.
Do not apply pressure to this hole. Attach tubing to the vent hole and place the end of the tubing so it is not exposed to dust or water. For the rod end male thread, refer to page 247.
Do not reuse if disassembled. High strength adhesive is applied to the portion of the connection that is threaded to prevent it from loosening, and it must not be disassembled.
Identifying Version Symbols For versions lower than V2.0 and S2.0: Do not use with controller parameters higher than V2.0 or S2.0. Applicable models Applicable models JXC91m Series JXCD1m Series JXCP1m Series JXCE1m Series For versions higher than V2.0 and S2.0: Do not use with controller parameters lower than V2.0 or S2.0.
Customers do not need to apply for a license to use this equipment. Be sure to comply with the following precautions. Do not disassemble or modify the product. Disassembly and modification are prohibited by law.
Do not use in locations where there is splashing or spraying of oils and solvents. Since this unit is open type, if water or oil, etc. make an ingress etc., the internal circuit may be corroded and result in a malfunction or damage. 2. Ground the piping when induction noise is expected to be generated from piping.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Specifications x100 IP address x 10 1 DIP SW Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Technical documentation giving detailed configuration information and the GSD file can be found on the SMC website (URL http://www.smcworld.com). Specifications Do not operate in an atmosphere containing flammable or explosive gases.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Connect valve manifold to the SI unit. Refer to the EX260 series valve manifold section in the valve catalogue for valve manifold dimensions. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.
Handling notes 6.1 Cautions for handling of the vertical auto switch unit (1) Be sure to connect a load to the switch before turning the power supply on. (2) Do not let objects drop onto or dent the product or subject it to strong impact when handling. (3) Do not use the product in the presence of a strong magnetic field. (4) When using two or more cylinders with auto switches closely in