Table 6-4 Seal Cap Part Numbers 14 - IN20267 Summary of Product Elements 7. Figure 7-1 MPC Product Elements Drawing N o .
Refer to page 14 for Safety Instructions, Handling Precautions for SMC Products (M-E03-3) for Air Preparation Equipment Precautions. Compressor Air Delivery Caution Use an air compressor with an air delivery of 50 L/min or larger.
14.5 17.5 Rc1/4 Rc3/8 Rc3/8 9 8 8 14 17.5 20 124 156 188 148 198 236 39 41 51 52 52 72 63 80 100 50 54 47 38 42 35 128 128 148 28 28 48 110 140 166 142 180 210 28 25.5 32.5 88 92 85 (mm) Bore size (mm) X XA XB XC XL YY YL Z 24 28 11 63 80 100 8 10 10 6 7 7 5 6 6 80 100 124 4 5 5 20 24 28 M10 X 1.5 M12 X 1.75 M14 X 2.0 (mm) MGTM (Slide bearing) MGTL (Ball bushing bearing) (mm) AA A E DB Bore
14 Rubber mount Return spring NBR Stainless steel 15 15 DIN connector type solenoid coil Tube assembly Stainless steel 16 16 Clip Nut Stainless steel Brass 17 17 DIN terminal gasket Rubber mount CR NBR 18 18 DIN connector DIN connector type solenoid coil 19 Clip Stainless steel 20 DIN terminal gasket CR 21 DIN connector 229 Series VCH40 Dimensions VCH41 (N.C.) 1 (56) 41 62 50 17 (44)
No.PS-OMU0008CN-D // ZSE20C(F) ISE20C(H) 2 9 11 12 16 16 19 21 [] 24 25 3 26 28 30 30 30 F0 32 F1 OUT1 33 F2 OUT2 36 F3 38 F4 39 F5 FUNC 41 F6 43 F10 44 F11 50 F80 51 F81 52 F82 54 F90 55 F96 57 F97 58 F98 60 F99 62 63 67 67 68 77 77 79 -1No.PS-OMU0008CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems
The buttons cannot be operated. 14 Product failure Replace the product. Check that the panel mount adapter and the product are correctly assembled. Mount the product on the panel correctly. Incorrect installation 15 The product is loose. Product failure Replace the product. Rework the piping.
Sub display (left) setting Set the sub display (left) from the selection list on page 41. Press the button to set. Move to sub display (right) setting. Return to function selection mode. Sub display (right) setting Set the sub display (right) from the selection list on page 41. Press the button to set. Return to function selection mode.
No.PF-OMJ0005CN-I () // PFM7## 2 10 13 14 14 16 17 20 22 22 F0 23 F1 OUT1 24 F2 OUT2 27 F3 28 F4 29 F5 30 F6 31 F7 32 F8 35 F9 36 F10 38 F11 39 F12 40 F13 41 F98 42 F99 44 45 49 50 53 54 54 57 59 73 -1No.PF-OMJ0005CN-I (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules
No.PF-OMP0002-H PRODUCT NAME Digital Flow Switch MODEL / Series / Product Number PFMB7501 PFMB7102 PFMB7202 Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 14 Installation 14 Piping 16 Wiring 17 Outline of Settings [Measurement mode] 21 Flow Setting (set value only) of OUT1 OUT2 [3 step
No.PF-OMP0001CN-F // PFMB7501 PFMB7102 PFMB7202 2 10 11 12 14 14 16 17 [] 21 OU1OUT2 {3 ] 22 22 [] 24 25 F0 26 F1 OUT1 28 F2 OUT2 36 F3 41 F10 42 F13 43 F20 44 F22 45 F30 46 F31 47 F80 OFF 48 F81 49 F90 50 F98 52 F99 53 54 58 59 61 62 62 65 67 -1No.PF-OMP0001CN-F (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems
Yes No YESSET FILE*NODATA *14 AX IS.
and Maintenance 31 Specification 41 Specifications 41 Dimensions 43 Accessories 46 -1No.EX-OME0015-F Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Part number of auto switchD-A9D-A9V Unitmm B A (When detecting retracted stroke end) H H 1 H 2 3 (When detecting extended stroke end) 5st 10st 15st 20st 25st 30st 35st 40st 4 6 1 6 11 16 21 26 13.0 10.0 20.0 10 1 6 11 16 21 26 31 36 41 16.0 9.5 19.0 16 1 6 11 16 21 26 31 36 41 18.0 12.0 24.0 Part number of auto switchD-M9D-M9VD-M9WD-M9WV Unitmm B A (When detecting retracted stroke end) H
Operation and Adjustment 13 to 14 8-1. Discharge from the product with drain cock 13 8-2. Manual drain discharge from the auto drain 14 9. Troubleshooting 15 10. How to Replace the Components 16 to 17 10-1. Bowl assembly Replacement 16 10-2. Element Replacement 17 11. Disassembly Drawing 18 12.
Operation and Adjustment 13 to 14 8-1. Discharge from the product with drain cock 13 8-2. Manual drain discharge from the auto drain 14 9. Troubleshooting 15 10. How to Replace the Components 16 to 17 10-1. Bowl assembly Replacement 16 10-2. Element Replacement 17 11. Disassembly Drawing 18 12.
Operation and Adjustment 13 to 14 8-1. Discharge from the product with drain cock 13 8-2. Manual drain discharge from the auto drain 14 9. Troubleshooting 15 10. How to Replace the Components 16 to 17 10-1. Bowl assembly Replacement 16 10-2. Element Replacement 17 11. Disassembly Drawing 18 12.
CRB1BW635 0.030 0 5 0.030 25 0 83 60 PORT 4-R7.5 Top ports (port position): CRB1BW63-SE, CRB1BW63-DE 75 0 0.052 28h9 17 0.006 0.017 15g6 5 B port B port 25 45 80 21 When the B port of body (B) is threaded, it is closed with a Rc 1/8 plug. 3 14 3 14 29 22 Body (B) 15 Body (A) 2-Rc 1/8 A port 14 14.9h9 0 0.043 12 15g6 0.006 0.017 28h9 0 0.052 25 A port B port 75 2-Rc 1/8 8 (8) 82 27
Gauge port 2) (Inlete, Outletr) Porting Configuration Pressure gauge Code r psig/bar unit MPa unit r e 0 6 10 20 40 60 Q No pressure gauge w q w q 600 psig/bar 3) 4.1 MPa 7 MPa 14 MPa 28 MPa 41 MPa 70 MPa qIN wOUT eGauge port (Inlet) rGauge port (Outlet) Connections (Inletq, Outletw) 1000 psig/bar 3) Ports Code 2000 psig/bar 3) Connections 4P V 4PN 4000 psig/bar 3) e 4P 4PN 4 4B NPT 1/4 inch
50 50 70 2.3 2.3 2.8 2.8 3.2 3 3 3 4 4 12 14 19 22 22 67 79 79 108 6 Series VHS20/30/40/50 Series VHS2510/3510/4510/5510 Specific Product Precautions 1 Be sure to read before handling.
A E Table 6 Unit:mm Model n J XYH-25 100.2 75.8 48 1 23.5 40 26 41 21.5 XYH-40 130 102.5 66 2 38 55 41 57 30 XYH-50 178 119 79 2 53 75 52 70 35 8 XM-OMP0005-A 6.