XMA series with KF (NW) flange A (mm) Model Weight (kg) Conductance (L/s) B (mm) CYV XMA-16 40 103 0.33 5 XMA-25 XMA-40 XMA-50 50 113 0.61 14 B 65 158 1.40 45 70 170 2.00 80 A 160 XMA-63 XMA-80 88 196 3.60 90 235 6.20 200 A : Common to all series. 479 Series Variations Operating pressure Flange size Shaft seal system Models Valve type Angle type In-line type Options Application Switch Indicator
120 Consumption flow rate [L/min (ANR)] Consumption flow rate [L/min (ANR)] Consumption flow rate [L/min (ANR)] 250 100 160 ZP3 200 80 120/150 120 150 60 ZP3E 40/60/80 80 100 40 ZP2 40 50 20 ZP2V 0 0 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure
[L/min (ANR)] 250 160 140 200 120 100 150 80 100 60 40 50 20 0 0 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] 7 Bernoulli Gripper ZNC Series Lifting ForceDistance from the Workpiece ZNC20m ZNC30m ZNC40m 12 14 6 0.5 [MPa] 12 10 0.5 [MPa] 5 0.5 [MPa] 0.4 [MPa] 10 0.4 [MPa] 8 Lifting force [N] Lifting force [N] 0.4 [MPa] Lifting force [N] 4
resistance Excellent heat resistance, and cold resistance Excellent mechanical strength Best heat resistance, and chemical resistance Pure gum property (specific gravity) 1.00-1.20 0.95-0.98 1.00-1.30 1.80-1.82 Impact resilience v g Abrasion resistance u to g Physical properties of blended gum Tear resistance v u to g v Flex crack resistance v u to v v Maximum operation temperature C 120 200
N O O F A U T O S W I T C H E S A U T OS W I T C H C A P A B L E A U T O S W I T C H 2 Pieces S 1 Piece See Accessories Without Auto Switch D With Auto Switch S T R O K E A D J U S T M E N T S T R O K E ( I N C H) M O U N T I N G With Adjustment Bolts (Std) B With Shock Absorber BC With Cap Type Shock Absorber BCS With One Cap Type Shock Absorber B Housing fixed P End plate fixed 100 1 200
Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston
Seal kit includes a grease pack (125 to 160: 40 g, 180, 200: 50 g, 250: 60 g). Order with the following part number when only the grease pack is needed.
The REB series is a sine rodless cylinder, with a maximum speed of 600mm/s, available in 3 bore sizes. Model REBR, a non-integrated guide, direct mount type is capable of mounting from the top or one side. Compact, external dimensions allow the REBR to be used when space is very limited. Model REBH is an integrated guide type cylinder. The use of a linear guide facilitates a large load,
Designation Description 2 Fieldbus interface connector (BUS IN) EtherCAT connection (M12 4-pole socket, D-coded) 4 5 2 *1: Blinking pattern SV24 V +24 V for solenoid valve 1 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 5-pole plug, A-coded) 3 2 SV0 V 0 V for solenoid valve 200 ms 200 ms 1 SI24 V +24 V for SI unit operation 3 4 Ground
EX245-EA2-1/2 9.1. . 9-1 EX245-EA2-1 . 9-2 EX245-EA2-2 61 No.EX-OMU0020CN 9.2. . 9-1 EX245-EA2-1 (WLH) mm 28.612061.5 200 g . 9-2 EX245-EA2-2 (WLH) mm 1412061.5 200 g EX245-EA2-2 P 36, 0.80.05Nm) 62 No.EX-OMU0020CN 10. 10.1. (EX245-DX1EX245-DY1) 88 EX600-ZT1 . 10-1 (EX600-ZT1) 63 No.EX-OMU0020CN 10.2.
. -42No.EX-OMT0009 Specification Specifications Basic Specifications Item Specifications Power supply voltage range Power supply for input and control: 24 VDC 10% Power supply for solenoid valve: 24 VDC +10%/-5% Power supply for input and control: 6.2 A (GW unit internal current consumption: 200 mA or less) Power supply for solenoid valve: 4 A Rated current Number of inputs and outputs
kpa [kpa] [kpa] 200 kpa 400 kpa 400 kpa [L/min] [L/min] PFMB7202(2000L/min) 200 kpa [kpa] 400 kpa [L/min] -65No.PF-OMP0001CN-F IN 3F.S.8 cm IN OUT [cm] -66No.PF-OMP0001CN-F PFMB7501/7102/7202 2x A B D E F H K L N PFMB7501/7102 70 30 43.7 37.2 15 14 26 18 13.6 PFMB7202 90 35 49.2 42.7 17.5 24 31 28 16.8 S T U V W PFMB7501/7102 24 22 32 40 50 PFMB7202 30 30 42 48 58 -67No.PF-OMP0001CN-F
(Page 82) H_1 (Setting of OUT1 hysteresis) Setting of OUT1 hysteresis (Hysteresis) 2 R/W U16 200 Y Setting range Refer to "Settable range list". (Page 82) P1L (n1L) (Lower limit of window comparator) Setting of OUT1 output set value (Lower limit of window comparator) 3 R/W S16 1200 Y 1220 0x04C4 Setting range Refer to "Settable range list".
(Custom range) Relationship between analogue input and digital display Set value A B 200 0 L/min 200 L/min 500 0 L/min 500 L/min 1000 0 L/min 1000 L/min 2000 0 L/min 2000 L/min 3000(Default) 0 L/min 3000 L/min 6000 0 L/min 6000 L/min 12000 0 L/min 12000 L/min 16000 0 L/min 16000 L/min 20 0 L/min 20 L/min USEr Input value (setting) Input value (setting) -31No.PF-OMU0007-D
Max. 1 NL/min 10 NL/min PF2A710 3.5 CFM x 10-2 35.0 CFM x 10-2 5 NL/min 50 NL/min PF2A750 18 CFM x 10-2 176 CFM x 10-2 10 NL/min 100 NL/min PF2A711 3.5 CFM x 10-1 35.5 CFM x 10-1 20 NL/min 200 NL/min PF2A721 7 CFM x 10-1 71 CFM x 10-1 50 NL/min 500 NL/min PF2A751 18 CFM x 10-1 176 CFM x 10-1 : Analogue output is based on the rated flow range at normal condition.
. *1 Applicable fluidconductivity *1 5S/cm or more (micro Siemens/cm) Detecting method Electro static cupacity Ground*10 Negative ground Rated flow range 0.5 to 20 L/min 2.5 to 100 L/min 5 to 200 L/min Display range 0.424.0 L/min 2.0 to 120.0 L/min 4 to 240 L/min Set point range 0.424.0 L/min 2.0 to 120.0 L/min 4 to 240 L/min Zero-cut flow *2 0.4 L/min 2.0 L/min 4 L/min Min. setting unit
[%F.S.] 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 [s] [S] [MPa] [MPa] [MPa] [MPa] [ [ [ [ ] ] ] ] 2 69 No.LFE*-OMY0008 / / / / A B C 1 V 1.1 V 5 V 4 mA 4.4 mA 20 mA [L/min] LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 70 No.LFE*-OMY0008 2x )M12 () 1.6mm A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67
The proof pressure is double the operating pressure range. -70No.LFE*-OMZ0011 Analogue output Flow/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow [L/min] Model B Minimum Maximum A LFE1 0.5 20 LFE2 2.5 100 Flow rate 0 Minimum Maximum rated flow LFE3 5 200 rated flow Out of range -71No.LFE*-OMZ0011 Dimensions Note) The electrical entry
. (5) Any fluid which corrodes the internal fluid contact parts cannot be used. -25No.LFE*-OMZ0012 Characteristics Chart Flow rate characteristics (pressure loss) LFE1 LFE2 0.02 0.02 Pressure loss [MPa] Pressure loss [MPa] 0.015 0.015 0.01 0.01 0.005 0.005 0 0 0 5 10 15 20 0 20 40 60 80 100 Flow rate [L/min] Flow rate [L/min] LFE3 0.02 Pressure loss [MPa] 0.015 0.01 0.005 0 0 50 100 150 200
Specifications Model XLDV-25 XLDV-40 XLDV-50 XLDV-63 XLDV-80 XLDV-100 XLDV-160 Flange (valve) size 25 40 50 63 80 100 160 Actuating type Normally closed Fluid Vacuum of inert gas Operating temperature oC 5 to 60 Operating pressure Pa Atmospheric pressure to 1 x 10-6 Main pumping 14 45 80 160 200 300 800 Conductance l/s Note 1 Initial pumping 0.53 28 2.511 48 418 6.531.5 6.531.5 Internal 1.3