SMC Corporation of America
Elite Part Number Search
Search Results "PFCQ531-04-A4-M"

G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell

NCA1-P325 NCA1-P800 NCA1-P1000 CB 1 1/4 1 1/2 2 CD 3/4 1 1 3/8 DD 17/32 21/32 21/32 E 3 1/2 4 1/2 5 F 5/8 3/4 7/8 FL 1 7/8 2 1/4 3 LR 1 1/4 1 1/2 2 1/8 M 3/4 1 1 3/8 MR 7/8 1 1/4 1 5/8 R 2.56 3.25 3.81 Weight (lbs) 3.11 5.80 10.42 Note: Pivot pin is not included Clevis Bracket CB CW CW CD MR BA E LR DD AA M F E FL Dimensions Part No.

Pressing the + key will move the screen to Input number 04. Inputs, Outputs, Keys, and Memory bits can be accessed in this manner.

G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm

Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.

3 Ejector assembly ZK2 EJ A W 10 Nozzle nominal size 07 0.7 10 1.0 12 1.2 15 1.5 Bellows type with groove Flat type with groove 257 ZHP Series Dimensions 30 N 70 Silencer In the case of Flat type P 16.6 EXH. 24.7 P F E D C A PD port 3 6.2 K M Female thread mounting M Male thread mounting Unlocked: 32.2 PD port 2 Locked Unlocked J PD port 1 G H P port L E F 6.2 10 7.8 6.2 Lock screw 14.4 1.4

Compressed air 1.0 MPa Fluid Max. operating pressure Min. operating pressure 0.05 MPa 1.5 MPa Proof pressure Ambient and fluid temperature Filtration degree Element life 5 to 60C 3 m (95% particle size collection) 2 years (1 year for A type) or when pressure drop reaches 0.1 MPa 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) in the case of types with auto-drain.

M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7

For information on tubing connection, refer to the pamphlets High Purity Fluoropolymer Fittings Hyper Fitting Series LQ1/2 Work Procedure Instructions (M-E05-1) or Flare Type Series LQ3 Fitting Procedure (M-E06-4). (The pamphlets can be downloaded from the SMC website.) Caution 1.

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage

Please contact us for the latest version.sales@ocaire.com, DISPLAY UNIT PF2W720-04-27-M, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.35829 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Operating fluid temperatureLinearityRepeatabilityTemperature

B H C D d NT-02 NT-03 NT-04 M8 X 1.25 13 5 15.0 12.5 CJP M10 X 1.25 17 6 19.6 16.5 M14 X 1.5 22 8 25.4 21.0 CJ2 Mounting Nut (mm) CM2 Material: Carbon steel C85 Applicable pin part No. Part No.

(A red color spot indicates the replacing time.) 5 to 60C 0.01m(95% particle size collection ) Oil mist removal rate Less than 3.5 particles 0.3 m or larger per liter of air ( 100 particles or less per cubic foot) Element Color Indicator (When element becomes saturated with oil the element surface changes from white to red.)

8000 AMF801 24000 AMF901 Model Rated flow (l/min (ANR)) Port size (Nominal size B) 2B Flange Weight (kg) 40 2B/3B/4B Flange 120 Specifications Compressed Air 1.0MPa Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature 0.05MPa 1.5MPa 5 to 60C Filtration rating 0.01m(95% particle size collection) Oil mist removal rate Less than 3.5 particles 0.3 m

Note 1) l (Drill through) Cotter pin d D m Dd9 L H B C 3 x 18l 4 x 25l 4 x 35l M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 36 51 72 4 4.5 5 3 4 4 44 60 82 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 -0.040 -0.076 -0.050 -0.093 -0.065 -0.117 Note 1) A cotter

J 1n 114 250 3/8 350 112 450 3/4 5 5 0 1 650 1 1i2 850-2 I I Port Sr" I PT pofts ilodel Bracket Beplacement Element AMG150 BM5'I AMG-EL150 02 1/4 (AMG 1s0) 03 3y8 (AMG 250) 04 1/2 (AMG 350) 06 3/4 (AMG 4s0) 1 o 1 ( A M G 5 5 O ) 14 1 1/2 (AMG 6s0) 20-2(AMGsso) AMG250 BM52 AMG-EL25O AMG35O BM53 AMG-EL35O AMG45O BM54 AMG-EL45O AMG550 BM55 AMG-EL55O AMG65O BM56 AMG-EL65O AMG850 BM57 AMG-EL85O

Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And. Rotation Of Auto Switch luto Swilch 9(r, 160' Ewn a small torque generated by the rotary actuator. due to inertia, can cause qamage.

Bore size (mm) Part No. l Dd9 L m d H B C D Applicable cotter pin 3 X 18 l 4 X 25 l 4 X 35 l 4 X 40 l 0.040 0.076 0.050 0.093 0.065 0.117 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 NT-12M CD-M03 CD-M05 CD-M08 IY-12 32 40 50, 63 80 100 125 32, 40 50, 63 80, 100 125 10 14 22 25 36 51 72 44 60 82 4 4.5 5 5 3 4 4 4 M10 X 1.25 M14 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 M27 X 2.0 6 8 11 13 16 16 17

Target position: 100.000[mm] (=10 [m] = 186A0h) Target speed: 100[r/min] (=10 [0.01r/min] = 2710h) Acceleration time constant: 100 [ms] (= 64h) Deceleration time constant: 100 [ms] (= 64h) The setup value is as follows.