SMC Corporation of America
Elite Part Number Search
Search Results "NCDMKC106-1000"

Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -29No.EX-OMN0011-F Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.

Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -35No.EX-OMO0030-E Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.

Item Specifications Cable O.D. 7.7 mm Data pair 0.5 mm2/AWG20 Conductor nominal cross section Drain 0.34 mm2/AWG22 Wire diameter (Including insulator) 2.55 mm Min. bending radius (Fixed) 77 mm -30No.EX-OMP0005-I Power supply connector (1) Cable with power supply connector Part number: EX9-AC0 1 0-1 Cable length (L) 1 1000 [mm] 3 3000 [mm] 5 5000 [mm] Item Specifications Pin No.

cable specification> Cable: Shielded twisted pair cable (Type-A cable) Impedance 135 to 165 (3 to 20 MHz) Capacitance between conductors Less than 30 pF/m Conductor resistance 110 /km or less Wire diameter 0.64 mm or more Conductor area 0.34 mm2 or more Transmission speed and maximum cable length Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 12000 Cable length (m) 1200 1000

Enclosure IP40 Operating humidity Operation, Storage: 35 to 85% RH (No condensation) Environmental Withstand voltage 1000 VAC for 1 minute between terminals and housing resistance Insulation 50M or more between terminals and housing resistance (with 500 VDC megger) Temperature characteristics +/2%F.S.

Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the work piece. 1) Discharge characteristics (Discharge time from 1000 V to 100 V) 2) Discharge characteristics range (Discharge time from 1000 V to 100 V) 25 2 Air flow scale: 1 Air flow scale: 2 1 20 3 Air flow scale: 3 Discharge time [s] 15 s 10 5 4 Air flow scale: 4 0 0 300

(Page 9) 6 Bushing (bearing) 1000 Lateral load applied to rod end {N} (fR)[N] 100 100 80 63 50 10 40 32 1 1900 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.

Maximum stroke (mm) Basic Bracket Head side flange, Foot, Single clevis Rod side flange Double clevis Bore size Center trunnion 125 1000 or less 1600 or less 140 1000 or less 1600 or less 160 1200 or less 1600 or less 180 1200 or less 1569 or less 200 998 or less 250 813 or less 320 495 or less Note: Air cylinders with a 180 or more. have the stroke range falling within the scope of the second

.: 2 and 4) Max. load current 80 mA Max. impressed voltage 30 V (NPN output) Residual voltage 1 V or less (80 mA load current) Response time 2.5 ms (Chattering-proof function working: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms selectable) Short circuit protection Provided Repeatability 0.5%F.S.

(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 end 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.

Enclosure IP65 Operating temperature range 0 to 50 oC (No freezing and condensation) Environment Operating humidity range Operation, Storage: 35 to 85% R.H. ( No condensation) Withstand voltage 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.

Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -41No.EX-OMP0013-E Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.

0 are shipped as single units, a grease pack is included (10 g per 1000 strokes). Order with the following part number when only the grease pack is needed.

0 are shipped as single units, a grease pack is included (10 g per 1000 strokes). Order with the following part number when only the grease pack is needed.

Center Q1 = 0.019 + 0.040 + 0.019 + 0.040 = 0.118 L(ANR) End Center End Center Air consumed in the tubing is calculated using formula (2), as shown below. 0.5 0.1 Q2 = 12.6 x 1000 x x 10-6 = 0.063 L(ANR) An entire stroke includes two rotations from end to center where the air is consumed. Thus, the total air consumption Q of the rotary table and tubing is obtained as shown below.

Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series

The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

mm +1.8 0 +1.4 0 +1.8 0 Stroke tolerance Up to 1000 mm, Up to 1200 mm Up to 1500 mm CM2 JIS class 2 Thread tolerance Rubber bumper/Air cushion Cushion C85 Basic, Axial foot, Front flange, Rear flange, Front trunnion, Rear trunnion, Clevis (Used for changing the port location by 90 degrees.)

The maximum detectable piston speed is: Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Time load applied (ms) V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.