Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Support bracket: Double End Boss-cut, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Pressure(MPa): 0.05~1.0, Cushion: Air cushion, Support bracket: Double end, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, End Locking: No, Valves: No, Cushion: Air cushion (ø10 to ø25 N only), Operating Pressure(MPa): 0.05

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, End Locking: No, Valves: No, Cushion: Air cushion (ø10 to ø25 N only), Operating Pressure(MPa): 0.05

(no condensation) Temperature characteristics 3%F.S. max. (15 to 35 C, 25C reference) 5%F.S. max. (0 to 50 C, 25C reference) Withstand voltage 1000 VAC, for 1 minute between the external terminals and case Insulation resistance 50 M or more (at 500 VDC) between external terminals and case Standards and regulations CE, RoHS Port size (Rc, NPT, G) 1/8, 1/4 3/8 1/2 Materials of parts in contact

Accuracy related to temp Stability: +/0.1 C After identifying a problem be sure to check the cause and take (Circulating fluid OUT is directly connected with IN) Output shut off alarm function Cooling capacity Approx. 220W (Flow rate 1L/min, set temperature 25C and ambient temperature 25C) necessary countermeasures before turning on the power. 3.4 Connector Specifications The product has

Ph (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) * 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max. 50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (Ph4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L) Max.200 Max.70 Calcium hardness (mgCaCO3/L) Max.150 Max.50 Standards Ionic silica (mgSiO2/L) Max.50 Max.30 Iron (mgFe/L) Max.1.0 Max.0.3 Copper

Cooling capacity (Set temperature 25C and ambient temperature 25C) Approx. 200W Approx. 400W Approx. 510W Approx. 800W Approx. 1000W (Flow rate 3L/min) (Flow rate 3L/min) (Flow rate 3L/min) (Flow rate 4L/min) (Flow rate 4L/min) Circulating fluid Water, Ethylene glycol solution up to 20% The compatibility of equipment is the responsibility of the person Tank capacity Approx.1.3L who designs

) 2% F.S. or less 1% F.S. or less 2% F.S. or less 1% F.S. or less Linearity 0.4% F.S. or less 0.2% F.S. or less Effects to the output value due to supply voltage: 0.8% F.S. or less Repeatability Temperature characteristics 2% F.S. or less (based on 25C) Enclosure IP40 Ambient humidity range Operating/Stored: 35 to 80% RH (No condensation) Withstand voltage 1000 VAC or more, 50/60 Hz for 1

Allowable operating cycle under the specifications set in this catalog is shown below. 1.2 million times RB08 2 million times RB10 to RB2725 Note) Specified service life (suitable replacement period) is the value at room temperature (20 to 25C). The period may vary depending on the temperature and other conditions.

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance410 g3/8

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance410 g3/8

2% F.S. or less (15 to 35C, based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance660 g3/8

2% F.S. or less (15 to 35C, based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance660 g3/8

2% F.S. or less (15 to 35C, based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance660 g3/8

2% F.S. or less (15 to 35C, based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Output for display unitAnalog outputAnalog output12 to 24 VDC (ripple ?10% or less)20 mA or lessEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistance660 g3/8

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?