0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7 250 0.94 340 1/8 90 0.7 250 0.94 340 1/4 115 2.3 810 2.3 810 1/4 130 2.3 810 2.3 810 3/8 124 0.2 4.6 1,670 4.6 1,670 1/4 221 0.35 4.6 1,670 4.6 1,670 3/8 214 4.6 1,670 4.6 1,670 1/2 205 7.9 2,840 7.9 2,840 1/4 242 11.9 4,270 11.9 4,270 3/8 233 11.9 4,270 11.9 4,270 1/2 224 Note) Flow rate values are measured at 0.5 Mpa and 20C
temperature Round lock nut With seal, Round lock nut, Nickel plated Option Weight (g) 181 106 64 29 10 6 3 Flow rate L/min (ANR) 105 230 460 920 1700 20 Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.32 0.7 1.4 2.8 5.2 0.06 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 0.2 Free flow 0.4 0.2 0.3 0.2 0.3 0.4 Note 1) Flow rate values are measured at 0.5 MPa and 20C
Sulfuric acid (30%, Room temperature) 4 Phosphoric acid (50%, Room temperature) 5 CY Ammonium hydroxide (28%) 6 MQQ M Inorganic alkali Sodium hydroxide (30%, Room temperature) 7 Calcium hydroxide 8 RHC Magnesium hydroxide 9 Acetylene 10 MK(2) 11 Formic acid (25%, Room temperature) Organic solvent 12 Citric acid RS Q G 13 Acetic acid (10%, Room temperature) RS H A Lactic acid (5%, 20C
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
(Standard type: Coil temperature 20C, at rated voltage. Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition.
It is strongly recommended to use clean dry air (with a dew point at approximately -20C). 4. Air connections should only be made with the pressure supply turned off. Flush the system before piping to prevent foreign matter from entering inside the product. 499
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
ANR: 20C at atmospheric pressure, relative humidity 65% 1 mg/m 3 (ANR) 0.8 ppmW/W Note 2) If there is a special law under operation, the law has ultimate priority. Note 3) It describes the grade of compressed air quality based on ISO8573-1: 1991 and JIS B 8392-1: 2000. (Refer to table on top in following page.)
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Calcium hydroxide 8 RHC Magnesium hydroxide 9 Acetylene 10 MK(2) Formic acid (25%, Room temperature) 11 Organic solvent 12 Citric acid RS Q G 13 Acetic acid (10%, Room temperature) RS H A Lactic acid (5%, 20C) 14 15 Linseed oil RZQ 16 Polassium
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
The ZSE/ISE20A/20B/20C series operation manual can be found here.
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches. GUIDED CYLINDER. Cylinder
The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., CYL, PRECISION
Specification: Standard Type (Not Clean Room), Bore Size: 8 mm, Symmetric Type: Standard, Stroke: 15mm, Adjuster: C (Metal Stopper Both Ends), Function: w/o Axial Piping, Switch Rail: N (w/o Magnet & Switch Rail)