l Cross section C-C Cross section C-C #i .. :: fl ffi -i+-sLJ rr Model D f G, I K L !,!
Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit
PEND Petroleum CW-6H Water-glycol, Emulsion For 2 1/2B, 3B CW-6H-W Phosphoric ester CW-6H-V Petroleum D-73H Water-glycol, Emulsion For 1/2B to 1B D-73H-W Phosphoric ester D-73H-V Petroleum D-74H Cap Water-glycol, Emulsion For 1 1/4B to 2B D-74H-W Phosphoric ester D-74H-V Petroleum D-75H Water-glycol, Emulsion For 2 1/2B, 3B D-75H-W Phosphoric ester D-75H-V 506 Suction Guard FHG Series How
D/MS3102A20-15S Connect the DC cable connector of the heat exchanger. 6 Contact b for upper/lower temp. limit alarm (closed when alarm occurs) A F Alarm output connector D-sub 9 pin (pin type) 7-9 Unused G E B 6. Communication connector: D-sub 9 pin OMRON Corp. XM2D-0901 or equivalent, holding screw M2.6 Connection cable: With shielding 22AWG or more Pin No.
/PL / OSSD SIL 2 2 2 3 3 3 3 3 SIL CL 2 2 2 3 3 3 3 3 * 2 2 4 3 4 ** 4 3 Cat. 3 PL d d d e d e e d *:Cat. 3 EN13849-2 2 N.O. **:Cat. 18 No.EX##-OMY0006CN 3.3.8. SI 0 SI 0 A SI 1. 2.I/O 3.SI 4. 5. 10 0 I/O 0 "0"= SI 72 72 SI 72 SI SI 16 SI SI SI SI 0 16 19 No.EX##-OMY0006CN SI SI SI 16 SI SI 20 D 3.3.9. GSDMLFDCML 3.4.
Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers.
D-H7BALD-H7NF D-G59WD-G5PWD-K59W D-G59FD-G5NT D-C73CD-C80C D-B54D-B64D-B59W 3. 4. () () (M4 1~1.2Nm (M3 0.6~1Nm 11 <> D-M9NM9PM9BM9NM9PVM9BV D-M9NWM9PWM9BWM9NWM9PWVM9BWV D-M9NAM9PAM9BAM9NAM9PAVM9BAV D-A90A93A96A90VA93VA96V 5. <> 6080 D-M9A(V) M3M3 0.60.7Nm (M2.5) (M2.5)0.050.1Nm 56mm 1)(M2.5) 2)M3 BMA3 A 12 4 1) (BMA2-A)(BJ5-1/) () 2) (BMA2-AS/)(BJ4-1/) D-M9A(V) () BBA3:D-B5,
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
side End block assembly L SX3000-53-1A SX5000-53-1A For U side 5 Connector box VZ3000-106-1A For 24VDC only 6 Rail stopper TXE1-SMC Maybe by Kasuga Electric Works SY3000-43-1ASY000-43-2AType D, 2 to 8 stations Type u, 9 to 16 stations SY3000-43-2ASY3000-43-3AType D, 9 to 16 stations Type u, 2 to 8 stations 7 Connector assembly SY3000-43-1NASY3000-43-2NAType D, 2 to 8 stations Type u, 9 to
As a guide, turn 90 from the position where it comes to feel tight. 12 < Applicable Auto switches > Solid state auto switch D-F59F5P D-J59J51F5BAL D-F59WF59PWJ59W Reed auto switch D-A53A54A56A64A67 D-A59W Fig.5 Mounting and movement of the auto switch (1) Fix the auto switch on the auto switch mounting bracket with the auto switch mounting screw (M4) and install the set screw. (2) Fit the
Weight (g) d L4 Model L3 T D1 H D2 D3 L1 L2 Max. Min.
Size ASF Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
D + + MADE IN JAPAN MADE IN JAPAN SMC SMC Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22
D-sub Connector. Series SV D-sub Connector. How to Order . Manifold Electrical Wiring. Dimensions . Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV3000 for D-sub Connector. Series SV4000 for D-sub Connector. Flat Ribbon Cable Connector . Series SV Flat Ribbon Cable Connector.
Proper tightening torque (Nm) C(D)U10-D 50 (75) 56 (86) 62 (92) 68 (98) 74 (104) 80 (110) 6, 10 16 20, 25 32 1.08 10% 2.45 10% 5.10 10% 8.04 10% M3 M4 M5 M6 C(D)U16-D 95 (128) 106 (143) 117 (154) 128 (165) 139 (176) 150 (187) 172 (209) 194 (231) C(D)U20-D 176 (230) 193 (252) 210 (269) 227 (286) 244 (303) 261 (320) 295 (354) 329 (388) C(D)U25-D 262 (335) 286 (364) 310 (388) 334 (412) 358
1 x 4 1.1 x 8 R 1/4 R 1/4 R 1/4 R 1/4 14 14 14 14 20 20 20 20 14 14 14 14 D 2 A Connection thread H1 L1 Copper extension nozzle: KNL (mm) Model Nozzle size D Outside diameter L1 Outside diameter KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 1.5 2 1.5 2 6 6 6 6 300 300 600 600 D L1 Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for
A Input/Output specifications 22 30 62 NPN open collector 2 output + Analog output Bracket D NPN open collector 2 output + Auto shift input Refer to the dimensions for the difference between brackets A and D. D PNP open collector 2 output + Analog output 70 PNP open collector 2 output + Auto shift input Option Note) Auto shift input is used for the auto shift function.
(Cable length) Product image Both straight Both angle Number of functional poles M12: 4 pins Key type M12: D-coded 1 2 1 (Yellow) : TD+ 2 (White) : RD+ 3 (Orange) : TD 4 (Blue) : RD Pin assignment 3 4 Plug, D-coded (Viewed from the plug) Fixed cable length 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m Wiring Cable O.D. 6.5 mm Conductor nominal cross section 0.34 mm2/AWG22 Wire O.D.