D. P. Lube (Unit) Series ALD(U)600/900 F.R.L. Standard Specifications Centralized control of multi-point lubrication (1) Model name D.P . Lube D.P . Lube Unit ALDU600 ALDU900 ALD900 ALD600 AV Model Low oil consumption volume 1 4 1 1 1 4 1 1 3 4 1 3 4 1 AU Simplified oil feeding volume setting in which only the pressure differential is adjusted.
NPN(1 )+ (15 V) PF2A7--29--X560 NPN(1 )+ (420 mA) 22 PF2A7--68--X560 PNP(1 )+ (15 V) PF2A7--69--X560 PNP(1 )+ (420 mA) / ZS-37-A () 3 m 100 g ZS-37-B (L ) 3 m 100 g ZS-29-T 4 (312 ) 40 g -11No.PF-OMO0007CN (IN ) 1 DC(+) 2 OUT2 3 DC(-) (OUT ) 4 OUT1 INOUT (UP) (SET) (DOWN) LED (OUT1) (OUT2) (OUT1) LED (OUT1) OUT1 ON (OUT2) OUT2 ON (UP) ON/OFF (SET) (DOWN) ON/OFF -12No.PF-OMO0007CN D
D E F G H I ZS-31-X188 20 9 R1/8 Rc1/8 14 1.5 ZS-31-X175 29 13 R1/4 Rc1/4 17 1.6 -18No.PS-OMS0005-E Revision history A: Contents are added. B: Contents are added. C: Contents revised in several places. D: Contents revised in several places. E: Contents revised in several places.
Printed in Japan. 1st printing November, 1999 D-SMC.L.A. P-80 (YG)
L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
C US How to order ISO 5599/2 Plug-in Manifold VV8 1 5 02 03 D T Size 1 Size 1 2 Size 2 3 Size 3 Port Thread Rc(Pt) T NPTF F G(PF) Number of Stations 1 1 Station Location of P, EA, EB port D Bottom U Top 10 10 Station Note) SU and TBU require one station.
(Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 16850 W. Victor Road New Berlin. Wl 53151 Tel: (414) 827-0080 FAX: (414) 827-OO92 5377 Glen Alden Drive Richmond, VA 23231 Tel: (804) 222-2762 FAX: (80a) 222-5221 SMC Pneumatics Inc.
Suite D Poway, CA 92064 TEL: (858) 679-190s FAX: (858) 679-1904 ARGENTINA SMC Argentina S.A. CHILE SMC Pneumatics (Chite) Ltda.
Intrinsically Safe Valve 5 Port Solenoid Valve Series 53-SY5000/7000/9000 Body Ported Electrical Entry L and LL Hazardous Location Class I Division 1 Groups A, B, C, D Electrical Entry TT Hazardous Location Class I, II, III Division 1 Groups A, B, C, D, E, F, G Single Unit Warning Do not install in Zone 0 (as defined in IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009)
How to Order 6N 1 1 D B 25 50 LEY X5 R o Made to Order: Dust-tight/ Water-jet-proof q w e r t y u i !0 !1 !2 !
Connected A B C D E F G H I J IDF190D JIS10KFF 80A(3B) flange 750 1510 1320 375 480 600 700 800 355 427 IDF240D JIS10KFF 100A(4B) flange 770 1550 1640 385 703 730 700 800 355 467 Auto drain is included in the package.
IDX-OM-X004-D PRODUCT NAME Heatless Air Dryer MODEL / Series ID20-02 ID30-04 ID40-04 ID60 -06 Please read this manual prior of using the air dryer. Keep the manual readily available for reference. To Customers Thanks for purchasing SMC Heatless Air Dryer. This opertion manual must be read and understood throughoutly before handling.
For D-P4DW, 40 to 63 are available. Only D-P4DW type is assembled at the time of shipment. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Since there are other applicable auto switches than listed, refer to page 18 for details.
e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
Port size D 1: Refer to the PF2A3 /PF2W3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter.
Black Flow direction 1 Main circuit + Mounting hole Brown DC(+) Main circuit Port size D 12 to 24 VDC 2 Piping port (IN side) Blue DC(-) 3 White Analogue output Switch output 1 4 Restrictor D x 8 times Safety Instructions Description Item Analogue output: 1 to 5 V Output impedance: 1 k (load impedance: 100 k or more) Body The body of the product.
D) In the state of C), adjust shim so that the arm side block contacts the workpiece. E) Exhaust the air while in the clamped state, and confirm that the clamp arm does not open. 7 - Relation between shim thickness and clamping force 3 Use this figure as a guide as there is a tolerance of about 10% in the clamp cylinder body.
[Number of emitter cartridges/Bar weight] Bar length (mm) 300 380 620 780 1100 1260 1500 1900 2300 Number of emitter cartridges 3 4 7 9 13 15 18 23 28 Weight (g) 330 400 600 720 1000 1100 1500 2000 2500 29 Doc.No.IZ-OMK0015D 4-2.
Supply pressure MPa Supply pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0 Valve output pressure (MPa) Valve output pressure (MPa) Valve output pressure (MPa) 0.9 0.9 0.9 0.7 0.8 0.9 0.6 0.7 0.8 0.9 0.9 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.6 0.1 0.2 0.3 0.4 0.5 0.5 0.1 0.2 0.3 0.4 2000 4000 6000 0 0 0 200 400 600
MPa Supply pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0 Supply pressure MPa 0.9 0.9 0.9 0.7 0.8 0.9 0.6 0.7 0.8 0.9 0.9 Valve output pressure (MPa) Valve output pressure (MPa) Valve output pressure (MPa) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.6 0.1 0.2 0.3 0.4 0.5 0.5 0.1 0.2 0.3 0.4 4000 6000 2000 200 400 600