SMC Corporation of America
Elite Part Number Search
Search Results "AL50-06-3-A"

Indicator Insulated adapter (PPS) Set Nil No L Yes O-ring (FKM) Port size Pressure type Thread type Symbol Port size Symbol Pressure type Symbol Thread type Nil Standard H High pressure 03 3/8 04 1/2 06 3/4 Nil Rc A G B NPT Component Parts a Housing assembly 1 pc. b Mounting screw: M5 hexagon socket head cap screw 2 pcs.

Insulated adapter (PPS) Port size Pressure type Thread type Set Symbol Port size Symbol Pressure type Symbol Thread type O-ring (FKM) Nil Standard H High pressure 03 3/8 04 1/2 06 3/4 Nil Rc A G B NPT Component Parts a Housing assembly 1 pc. b Mounting screw: M5 hexagon socket head cap screw 2 pcs. c Spring washer 2 pcs.

PFMC 7 7 A*8 8 501 5~500L/min 2 102 10~1000L/min 202 20~2000L/min *7 Rc N NPT R F G*1 1ISO228 501 102 202 04 1/2 *7 06 3/4 OUT1 OU2 *5 A NPN NPN M SI*6 B PNP PNP 5 C NPN (1~5V) SI D NPN (4~20mA) 6:L/min:L E*2 PNP (1~5V) F*2 PNP (4~20mA) 1 G*2 NPN *3 M8(3m)*4 H*2 PNP *3 2 3 N M8 *4 / ZS-40-A M8 3 m ZS-42-A PFMC7501/7102 (M352 ) ZS-42-B PFMC7202 (M352 ) -10No.PF-OMS0001CN-A M8 1

14 4 2 12 12 25 17 18 25 5 1 3 46.5 12 12 2-3/8 EA,EB PORTS 22.5 22.5 L = 1/4 23.5 15 30.5 45 3/8 27 EA EB P 1/2 30.5 49.5 1/4, 3/8,1/2 P PORT 152.5 165.5 ALL DIMENSIONS ARE IN MILLIMETERS 11 Series VS R8b S ISO SIZE 2-3 SUB-BASE VS8w 03/04/06/10w SIZE 2 3/8, 1/2, 3/4 SIZE 3 1/2, 3/4, 1 2 PORTS A,B, PORTS 2-1/8 PILOT EXH PORTS A A B A B C SIZE 2 7 SIZE 3 9 2 MOUNTING HOLES SIZE 2 3/8 SIZE

OUT (2) 2 Port size (1) IN Port size 1/8 (6A) Symbol 01 02 03 04 06 Class 3 Class 2 Class 4 Voltage 1/4 (8A) 3/8 (10A) 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC 1/2 (15A) 3/4 (20A) Orifice size Orifice size (mm) Class 3 Class 2 Class 4 Symbol 2 3 4 5 7 10 Please consult with SMC regarding other voltages. 2 3 4 5 7 10 Electrical entry G Grommet C Conduit Note) Note

(1)EX600-ED2PWR INM12 5 B code 1 24 V() 2 0 V() 3 24 V() 4 0 V() 5 FE (2)EX600-ED3PWR IN7/8 5 1 0 V() 2 0 V() 3 FE 4 24 V() 5 24 V() (3)EX600-ED4PWR INM12 4 A code PWR OUTM12 5 A code 1 24 V() 1 24 V() 2 24 V() 2 24 V() 3 0 V() 3 0 V() 4 0 V() 4 0 V() 5 (4)EX600-ED5PWR INM12 4 A code PWR OUTM12 5 A code 1 24 V() 1 24 V() 2 0 V() 2 0 V() 3 24 V() 3 24 V() 4 0 V() 4 0 V() 5 -29No.EX-OMN0027CN-D

Grommet: VKF334-G-01 DIN terminal: VKF334-D-01 Base mounted type 33.5 16.7 26 4 Manual override (non-locking) A 12.7 20 10 18.5 20.5 3 32 71.5 Max. 10 2-4.3 (mounting holes) Applicable cord O.D. 4 to 6.5 48.5 Approx. 300 (lead wire length) 26 4 Pg.7 3 27 Manual override (non-locking) A 20.5 18.5 3 32 59 68 78 70.5 43.5 12 7.5 P R 13.5 11 33.5 7.5 12 43.5 P R 3-Rc(PT) 1/8 (ports P, A, R) 13.5

There is a danger of spatter causing a fire. Consult with SMC regarding use in this kind of environment. 3. Tube attachment/detachment for one-touch fittings 1) Attaching of tubing (1) Take a tube having no flaws on its periphery and cut it off at a right angle. When cutting the tube, use tube cutters TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc.

PF2A5--2 (With voltage output type) PF2A511, 521, 551 B Wiring 116 23 1.6 76.2 Brown (1) DC(+) Main circuit Black (4) OUT (Output for display unit) White (2) NC/Analog output 54 44 34 Blue (3) DC() Use this sensor by connecting it to a P/A remote type display unit Series PF2A2/3. 4-4.5 2-Port size 30 40 50 Connector pin numbers 2 1 (44.2) A 4 3 (mm) A B Output specification Pin no.

Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. *3) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.

Doc.No.MH*-OMY0023-A PRODUCT NAME Magnet Gripper Unit for Collaborative Robots MODEL / Series / Product Number MHM-25D-X7400A-CRX Contents Safety Instructions .2 1. List of included items .4 2. Parts description of the magnet gripper .5 3. Product Specifications .6 3-1.How to order .6 3-2. Specifications .7 3-3.Gripping force .8 3-4. Dimensions .10 3-5.

D-B5/B64 D-G5/K59 D-G5W/K59W (A set of band and screw) BA-02 BA-01 (A set of band and screw) BA-32 (A set of band and screw) BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) BA-08 (A set of band and screw) BA-10 (A set of band and screw) Note) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform,

Flow Characteristics/Weight C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Operating pressure range (MPa) Port size Grommet DIN terminal 0.10 0.13 0.13 0.10 0.13 0.13 0.13 0.13 0.13 0.13 0.41 0.32 0.32 0.41 0.32 0.59 0.32 0.32 0.59 0.32 2 3 2 3 2 3 VKF33 VKF33 Y VKF33 E VKF33 V VKF33 W VKF334 VKF334Y VKF334E VKF334V VKF334W 0.67

View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.

Doc.No.MH*-OMY0014-A PRODUCT NAME Air Gripper Unit for Collaborative Robots MODEL / Series / Product Number JMHZ2-16D-X7400B-CRX Contents Safety Instructions .2 1. List of included items .4 2Parts description of the air gripper .5 3. Product Specifications .6 3-1. How to order .6 3-2. Specifications .7 3-3. Gripping force .8 3-4. Gripping point .9 3-5. Dimensions .10 3-6.

Inch Size A L Connection thread size NPT (a) Weight g Effective area (mm) A H L Model (b) 1/8 1/4 3/8 1/2 AKB01-N01S AKB02-N02S AKB03-N03S AKB04-N04S 14.29 17.46 22.23 23.81 24.2 40 44.9 55.5 20.2 34 38.4 47.5 18 44 86 113 6.5 14 24 34 1/8 1/4 3/8 1/2 Connection thread size (b) Reference dimension after screwing into NPT threads.

bracket 1 3 5 6 AK 8 3 B 3 4 1 Port size ASS Applicable series Port size 01 02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Nil N F Rc NPT G Meter-out control Meter-in control Caution Be sure

;;l:=i.:., i:illl:i'l:l ,,:.a ;l';:':'':'" .r*,*i9.X,i t1*ff ,i=gr.g . ii : * f i'.f i,,.:,a.:.aa.':.: -: "' ,t*11*t3.s.&1*fi::{{'i: r:l:i, i:ar&i1 f i!.-r ..,;.;:li.i..i.i;t,l.il i.ii=i i i=i li,i !;;r,i:i l,t,t.t,::,:,,.4 a',::r:t:,. . *,,t;,,-:,i,:li=:3;d*:a*,,r.i,i t.i-i+,,i=r.t.r,,..r,r:,:t:*,:t:t i.3.li!i.i*i*!!i.

OUT(2) 1 Thread type Rc NPT G Nil N F IN(1) Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Port size Class 3 Port size 1/8 (6A) 1/4 (8A) Class 2 Class 4 Symbol 01 02 03 04 06 3/8 (10A) 1/2 (15A) Class B in AC has a rectifying circuit built-in. Class H is AC only. No rectifying circuit.