This compact cylinder is applicable within the range from 10 to 60 C. Make sure to keep it during operation. In case of immoderate use over the range, extreme wearing due to hardening of packing may result in air leak and lubrication failure as lubrication grease cannot perform fully. 11.
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.
CNG D-G39/K39 11 11 10 MNB Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming approximately 30% dispersion). It may vary substantially depending on an ambient environment. CNA CNS CLS CLQ RLQ MLU MLGP ML1C The above figure shows the mounting example of D-A9(V)/M9(V)/M9W(V)/ M9A(V)L.
Rod cover Tolerance h9 Clean room series Series 10-, 11-CUJ Two auto switches can be installed even for 4mm strokes.
Assembly of Optional parts 11 8. Troubleshooting 12 9. How to Replace the Components 13 to 14 9-1. Bowl assembly Replacement 13 9-2. Element Replacement 14 10. Disassembly Drawing 15 11. Dimensions 16 -1- Activated Carbon Filter Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
N Backlash Manual unlocking Theoretical Output 12 16 20 40 Rear end only 125 211 29 53 82 329 1mm Non-locking type only Standard Strokes (N) Operating pressure (MPa) Bore size (mm) Operating direction Piston area (mm) Bore size (mm) Standard stroke (mm) 0.2 10 8 23 17 40 30 63 47 98 72 161 121 251 188 0.4 20 15 45 34 80 60 126 94 196 143 322 241 502 377 0.3 15 11 34 25 60 45 94 71 147 107
speed (mm/s) 0.025 0.5 0.06 1 0.06 1 0.035 (0.025) 1 (0.5) 32, 40 32, 40 10, 16 10, 16 0.01 0.5 0.05 0.5 Figures in ( ) are for 11-CQ2X 20, 25, 32 50, 63, 80, 100 Air Cylinder Series CM2X Air Cylinder Series 10-/11-CM2X Compact Cylinder Series CQSX Compact Cylinder Series 10-/11-CQSX Bore sizes (mm) Min. operating pressure (MPa) Min. operating pressure (MPa) Min. piston speed (mm/s) Min.
DC (+) Brown Main switch circuit OUT Black Auto Switch Weights Unit: g DC (s) Blue D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Model 0.5 11 11 11 Lead wire length m 3 54 54 54 D-Y7PW, Y7PWV 5 88 88 88 DC (+) Brown Main switch circuit Auto Switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw DC (s) Blue Indicator light 3.4 2.5 SMC SMC 6.2 5 D-Y7BW, Y7BWV 29 OUT (+) Brown Main switch
Precautions on Design 3 10 11. Mounting Methods 4 11 12. Piping 5 13 13. Operating Environment 6 15 14. Speed Control 15 15. Troubleshooting 7 16 16. How to exchange seals 8 17 17. Construction 21 18. Auto Switch 25 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Range Stability * Stability is improved by increasing the response time setting. * Stability indicates the fluctuation width of the display or analog output. 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 10 20 30 40 50 60 70 80 90 4.0 3.5 Pressure [MPa] 3.0 Stability [% F.S.]
(mm) D2 L A M D1 Applicable tubing KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S M5 x 0.8 M6 x 1 38.5 11 13 39 35 8 10.4 16 2.5 4.0 4.0 4 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 1 8 M5 x 0.8 M6 x 1 12 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 12.8 15 17 1 8 1 4 1 8 38 39 42 43 44 20 26 28 34 42
I ' . 0.040 6 7 11 17 8 M3 x O.5 I. 16.5 10.5 6 B M10 X1.0 9 3 7 3 , 065 '10 . , jj:!'
Control unit types Nil None 100 VAC, 50/60 Hz 1 Base type/Electrical entry 200 VAC, 50/60 Hz 2 5 9 Plug-in type: Stacking type manifold base with D-sub connector 24 VDC Other 51F Option Plug-in type: Stacking type manifold base with attachment plug lead wire 51G Control equipment Symbol Nil A AP M MP F G C E Non plug-in type: Stacking type manifold base 51 Air filter regulator with auto-drain
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.
Units selection function 30 F 1 Setting of OUT1 34 F 2 Setting of OUT2 37 F 3 Digital filter setting 39 F 4 Auto-preset function 40 F 5 FUNC terminal setting 42 F 6 Fine adjustment of display value 46 F10 Sub display setting 47 F11 Display resolution setting 53 F80 Power saving mode 54 F81 Security code 55 F82 Input of line name 57 F90 Setting of all functions 58 F96 Input signal check 60
C (No freezing) Ambient temperature 0 to 60 C (No freezing) Maximum viscosity 5000 mPas Weight (kg) 3.0kg Mounting orientation Horizontal (with mounting foot at bottom) Packaging General environment These are reference values given for rated temperature and tap water and are not guaranteed.
Looseness of bolts which fix the parts at each port (port, elbow fixing flange, port fixing flange, air port cover). 11 9.
() 90%RH () 2(0.5G) 4.9m/s IP20 200g() 220g(DIN ) 11 - 3.2 1 LED 2 STATION No.
Description Applicable model Material Note AW20 to 60-B Urban white Body Aluminium die cast AW20 to 40-B Polyacetal Bonnet Urban white AW60-B Aluminium die cast Option / Replacement Parts Option Material Part No. Thread No.
When ordering the auto switch separately, the auto switch mounting bracket (BMG2-012) is required. 711 MHW2 Series Specifications Air Fluid 0.15 to 0.7 MPa Operating pressure 10 to 60C Ambient and fluid temperature 0.2 mm Repeatability 20, 25: 60 c.p.m. 32 to 50: 30 c.p.m.