SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20B-L-M5-W"

Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: M5, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Individual Item, Operating Pressure Range(MPa): 0.3~0.5

Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: M5, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Individual Item, Operating Pressure Range(MPa): 0.3~0.5

Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: M5, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Individual Item, Operating Pressure Range(MPa): 0.3~0.5

Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: M5, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Individual Item, Operating Pressure Range(MPa): 0.3~0.5

Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: M5, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Individual Item, Operating Pressure Range(MPa): 0.3~0.5

NAN200,400 NAN500 -900 4.21 11071 NAN120-X200 Port size (NPT) M5 (NOM 10-32) Noise reduction lvax. operating pressure I 45 PS(10.2kg7c.rf) 40140.F (s -60.C) Operating temprature range Effective orifice mm2 (Cv) 5 (0.27) 20 0.1) .12 (3.3) \4/eight oz (g) 0.69 (17) Dimensions In.

Body size M5 M5 X 0.8 10 M5 Applicable tube O.D. 04 4mm With One-touch fitting 06 6mm ARJM10-6 Piping Elbow style 20 Flow Characteristics Supply pressure 0.7MPa Pressure Characteristics Initial setting: Supply pressure: 0.7MPa Secondary pressure: 0.2MPa Flow: 10 l/min(ANR) 1.5-3 Miniature Regulator ARJ1020F Construction/Dimensions Precautions Be sure to read before handling.

[101 to 101 kPa] 0 1 2 3 Option Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nil Without cable Sensor cable (3 m) M5 Port size L M5 x 0.8 Option Sensor cable (3 m) + Connector (1 pc.)

ASN How to Order AQ ASN2 03 ASV JIS Symbol AK Option Nil S None With seal ASS Port size ASR M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASF Thread type Metric thread (M5) Unified thread (10-32 UNF) R NPT Nil N Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Number of needle rotations 15-11-1 2 Series ASN Construction Component

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]