SMC Corporation of America
Elite Part Number Search
Search Results "ZSE10F-M5-B-PGR"

A specified earth leakage breaker is installed for option B [Earth leakage breaker], option B [Earth leakage breaker with handle] of each model.

HEC006 HEC012 HEC006 HEC012 Model No. label Model No. label Fig.4-1 Position of Model No. label Fig.4-2 Legend of Model No. label 4-2 Unit Overview 4.4 Appearance 4.4.1 HEC006 (C) 4xG D E A B F A B C D E F G HEC006 240 390 497 214 458 482 7 Unit: mm Fig.4-3 Outside drawings of HEC006 4-3 Unit Overview 4.4.2 HEC012 (C) 4xG D E A B F A B C D E F G HEC012 300 448 565 190 526 550 7 Unit: mm Fig

Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.

Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.

() A-(1) B+(3) B-(4) A B VFR510 A COM A B VFR520 A COM B 3 A COM B VFR5 40 5 8 VFR5000-OMN0001 VFR5000 Series/ (VFR500) (VFR510) VFR500 VFR510 () () 2.8Nm ) AC DC24V 3 (AB) (N.C.)

B A B B 45 45 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 1.0 (25.4) 1.0 (25.4) AP3650 AP3657 1.88 (47.8) 0.44 (11.2) 3.02 (76.7) 0.13 (3.3) 0.4 (10.2) 1.87 (47.5) A B B 0.44 (11.2) 3.6 (91.4) 45 1.0 (25.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) A B B Connections A B inch inch (mm) (mm) FV4 MV4 TW4 FV6 MV6 TW6 FV4 MV4 TW4 FV6 MV6 TW6

Note 2) 400 V type is provided with an earth leakage breaker -B as standard.

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).

/set 14 ZL1 Series Dimensions ZL112A(N)(-B) Valve (Without supply valve or release valve) 2 x 5.3 Mounting hole ( ) Recommended tightening torque: 1.2 to 1.5 Nm 53.2 114 Vacuum (V) port Applicable tubing O.D. B Air pressure supply (P) port Applicable tubing O.D.

With lock/226) 28 (64) Stroke 39 (4) 21 Motor cable (6) 70 58 47 6.7 17.5 Vacuum port Rc1/8 Note 3) 35 Encoder cable (7) Lock cable (4.5) Motor option B: With lock 8H9 ( ) depth 6 +0.036 0 13 n x 6.8 B 30 8H9 ( ) depth 6 +0.036 0 140 200 E C x 200 (= D) 25 Note 1) Please consult with SMC for adjusting the Z-phase detecting position at the stroke end of the end side.

Connector pin numbers 2 1 (43.5) 4 3 A B Pin no. 1 2 3 4 Output specification Pin description DC(+) NC/Analog output DC() OUT A Pulse output only 42 62 52 Pulse output + Analog output 72 Flow direction 18 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 80 32 70 58 46 45 2-Port size 2 45 4-5.5 36 (43.5) A A B Output specification 63 Pulse output only 77 73 87 Pulse

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).

Round plate (Including column) Position of rotational axis: Through the center axis (B) Number of teetha 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teethb 5.

A2 Bracket B (Horizontal mounting) Part no. Option Note ZS-28-CA-4 Sensor connector For PF3A7H ZS-46-A1 Bracket A Tapping screw: Nominal size 3 x 8 L (2 pcs.) ZS-46-A2 Bracket B Tapping screw: Nominal size 3 x 8 L (2 pcs.)

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C.

Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR-TK001 HRR050-A/W-20/40-UY Nut (M8) Bolt (M8) Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.

Pin description 1 DC (+) 2 Analog output Accumulated pulse output wiring examples 3 DC () 4 OUT1 4-I thread with depth J 40 Max. 30V 80 mA or less OUT1 Black Load H 0V Blue 50 msec PF2A7H--28 29(-M) A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80 mA Load Black 65 180 45 104 79 65 Rc 11/2, NPT 11/2, G 11/2 Rc 2, NPT 2, G

Connector pin numbers 2 1 (43.5) 4 3 A B Pin no. 1 2 3 4 Output specification Pin description DC(+) NC/Analog output DC() OUT A Pulse output only 42 62 52 Pulse output + Analog output 72 Flow direction 18 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 80 32 70 58 46 45 2-Port size 2 45 4-5.5 36 (43.5) A A B Output specification 63 Pulse output only 77 73 87 Pulse