SMC Corporation of America
Elite Part Number Search
Search Results "XLC-16-2"

P (Piping port) G E G NN ( I ) D X NA R Mounting nut N W K N F S + Stroke F ZZ + Stroke H B E G Mounting nut NN NA F N 12CY3B15 (mm) L 57 66 70 80 92 J 6 6 8 8 10 K 11 8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46

FH340-04 FH342-06 FH342-08 FH341-06 FH341-08 FH34 -10 FH34 -12 FH341-16 FH440-03 FH44 -04 FH44 -06 FH44 -08 FH44 -10 FH44 -12 FH441-16 FH441-20 FH441-24 FH540-03 FH54 -04 FH54 -06 FH54 -08 FH54 -10 FH54 -12 FH541-16 FH640-03 FH64 -04 FH64 -06 FH64 -08 FH64 -10 FH64 -12 FH641-16 96 50 80 160.5 275 57 217.5 5 3/8 1/2 3/4 1 1 1/4 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2

2 105 + 40 n = 4, 8, 12, 16 2 110 + 40 n = 4, 8, 12, 16 n 2 2 (Different sides, Same side), 1 90 95 100 10 D-Y69/Y7PV D-Y7WV 10 + 30 n = 2, 4, 6, 8 (n 2) 2 100 + 30 n = 4, 8, 12, 16 (n 4) (n 4) (n 4) 2 90 + 30 n = 4, 8, 12, 16 2 95 + 30 n = 4, 8, 12, 16 n 2 2 (Different sides, Same side), 1 115 130 20 120 125 n D-Y7BAL 20 + 45 n = 2, 4, 6, 8 (n 2) 2 (n 4) (n 4) (n 4) (n 4) 2 115

Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.

One-touch fitting 2, 4 2, 4 2, 4, 6 Vacuum inlet Barb fitting1 2, 4 2, 4 2, 4, 6 1 2 polyurethane tubing, 4, 6 soft tubing Vacuum Inlet Direction Lateral Y Type/ZP3-Y Connection Female thread Pad diameter 1.5 to 3.5 4 to 8 10 to 16 Connection thread M3 x 0.5 M5 x 0.8 M5 x 0.8 Female thread M3 x 0.5 M5 x 0.8 M5 x 0.8 Vacuum inlet One-touch fitting 2, 4 2, 4 2, 4, 6 Barb fitting1 2, 4 2, 4

No setting 1 4 2 5 7 2 5 3 2 2 3 5 3 1 MHZ2-16 No setting 3 2 4 1 MHZ2-20 MHZ2-25 MHZJ2-10 No setting No setting MHZJ2-16 No setting No setting 3 2 1 MHZJ2-20 MHZJ2-25 Note) "" in the table indicates a skip with no dimension.

16 ) 2 (Different surfaces, Same surface) 1 110 105 115 15 D-M9 D-M9W 110 + 40 (n4) 2 105 + 40 (n4) 2 15 + 40 (n2) 2 115 + 40 (n4) 2 n (n = 4, 8, 12, 16 ) (n = 4, 8, 12, 16 ) (n = 2, 4, 6, 8 ) (n = 4, 8, 12, 16 ) 2 (Different surfaces, Same surface) 1 80 90 85 10 D-M9V D-M9WV 80 + 30 (n4) 2 10 + 30 (n2) 2 90 + 30 (n4) 2 85 + 30 (n4) 2 n (n = 2, 4, 6, 8 ) (n = 4, 8, 12, 16 ) (n = 4, 8, 12

Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated).

Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.

Size Symbol 2 2 2 3 3 4 4 5 5 6 6 A B C A B A B A B A B 2 2 3 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" LVC LVA LVH LVD With reducer Basic size LVQ Note 1) Select a fitting the same

Formula examples with beams (Reference) L a b L a b L L L/2 L/2 L/2 L/2 Load/Shape conditions P P P P A C RA RB B A C RA RB B C A E D B RA RB RC RA=Pb/L RB=Pa/L W=P Formula (Reactive force: R, Total load: W) RA=RC=5Pb/16 RB=11P/8 RA=RB=P/2 W=P Mounting Position The basic mounting method is a horizontal lift.

Note 2) 6, 10, 16 . Integrated type 20, 25 . Non-integrated type Bore size 6mm 10mm 16mm 20mm 25mm 6 10 16 20 25 Series MQM is not auto switch capable. Mounting Bracket Types and Accessories L: Foot Note F: Front flange G: Rear flange C: Single clevis D: Double clevis Mounting bracket B: Standard Note 2) (1 pc.) (1 pc.) (2 pcs.) (1 pc.)

1.25 2 2 2 3 30 42 42 52 52 52 56 56 70 80 80 88 116 8 9 9 13 13 13 15 15 18 24 24 24 42 19 25 25 30 30 30 38 38 47 58 58 69 89 44 52 52 67 67 67 82.5 82.5 98.5 123 123 155 213 12 16 16 19 19 19 22 22 25 32 32 70 90 1 1.5 1 1.25 1.5 1.75 1.5 2 2.5 3 1.5 2 2 18 24 24 30 30 30 34 34 42 48 48 54 74 8 10 10 12 12 12 16 16 20 24 27 27 33 21 24 24 31 31 31 41 41 50 59.5 59.5 66 96 36 48 38 44 44

Note 2) Refer to Best Pneumatics No. 2-1 for lead wire lengths.

. 21 Auto Switch Mounting Series MGP Minimum Stroke for Auto Switch Mounting (mm) 12 16 20 25 32 40 50 63 80 100 Auto switch model No. of auto switches mounted 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 5 Note 1) 10 Note 1) 5 10 5 10 D-A9 D-A9V D-M9V 5 Note 1) 5 D-M9 10 Note 1) 10 5 Note 2) D-M9W 10 Note 2) 10 5 Note 2) D-M9WV D-M9AV 10 5 Note

load type (Through-hole and Both end tapped common): MQQLB 10, 16, 20 H thread effective depth C 2-M5 x 0.8 2 x 4-OB Counterbore depth RB 2 x 4-OA effective depth RA Y Q F I 4-N through M 0.2 D E K B + Stroke L M 0.2 A + Stroke E 25, 28 H thread effective depth C 2-Rc 1/8 2 x 4-OB Counterbore depth RB 2 x 4-OA effective depth RA Y Q F E J I 4-N through M 0.2 D W K B + Stroke L A + Stroke

2 Material Note Component Parts No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !

position single 2 position single Allowable voltage fluctuation (B) 2 (A) 4 (A) 4 (B) 2 Standard DC Power consumption (W) With power saving circuit 100V 110V [115V] 200V 220V [230V] 1 (P) 1 (P) 5 (R1) 3 (R2) 3 (R) Apparent power VA 2 position double 2 position double AC (B) 2 (A) 4 (A) 4 (B) 2 Surge voltage suppressor Indicator light 1 (P) 5 (R1) 3 (R2) 1 (P) 3 (R) In common between 110 VAC

8, 12, 16 n -X n = 4, 8, 12, 16 2 (Different sides, Same side), 1 75 80 90 10 65 20D-Y69/Y7PV D-Y7WV (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 2) 2 n 90 + 30 80 + 30 n = 4, 8, 12, 16 75 + 30 n = 4, 8, 12, 16 65 + 30 n = 4, 8, 12, 16 15 + 30 n = 2, 4, 6, 8 n = 4, 8, 12, 16 Data 10-15-77