Series 20 Port size Symbol 10 30 M5 01 02 M5 1/8 (6A) 1/4 (8A) Electrical entry G Grommet Orifice size Orifice size (mm ) Series Symbol 1 1.6 1.6 2.3 3.2 2 3 4 1 2 1 2 3 2 3 4 10 20 30 17-2-64 5 Series VDW10/20/30 Compact Direct Operated 2 Port Solenoid Valve For Water and Air Standard Specifications Valve construction Direct operated poppet Fluid (2) Water (except waste water or agricultural
SUP = 0.2 MPa 20 SUP = 0.2 MPa VX2 10 10 VX 0 0 10 30 40 50 20 60 VX3 10 20 Discharge rate (l/min) Discharge rate (l /min) VXA Selection from Flow Characteristic Graph (PA3000) VN Required specifications example: Find the pilot air pressure and pilot air consumption for a discharge rate of 6 l/min and a total lifting range of 25 m.
-10AS G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8"1/2" 2.5, 4, 6 AS131F-M3 AS121F-M3 M3 x 0.5 6, 10, 16, 20 AS131F-M5 AS121F-M5 M5 x 0.8 6, 10, 16, 20 AS121F-U10/32 AS131F-U10/32 10-32 UNF Tube swivels 360 Universal type permits 360 piping swivel. (1) 20, 25, 32 AS221F-01 AS231F-01 R 1/8 20, 25, 32,
Dimensions Ionizer (Standard nozzle) / IZG10--01 Power supply connector One-touch fitting Applicable tube O.D.: Table 1 Table 1 Models Applicable tube O.D. 8 (mm) IZG10-08-01 IZG10-09-01 5/16 (inch) 20 Doc. no.IZ*-OMX0012-B Ionizer(Bypass nozzle)/ IZG10--02 AC adapter / IZG10-CG The AC adapter and power supply cable (AC adapter) are a set.
m AFJ20-02-40-S/AFJ30-03-40-S/AFJ40-04-40-S AFJ20-02-40-T/AFJ30-03-40-T/AFJ40-04-40-T 12 12 AFJ20-02-40-T AFJ30-03-40-T AFJ20-02-40-S AFJ30-03-40-S AFJ40-04-40-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-40-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 40 m Large flow type Nominal filtration rating: 40 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Station 3 2 1 D side U side Stations 02 03 2 stations 3 stations 20 20 stations Note) Maximum of 20 stations Electrical entry Grommet/Plug lead C How to Order Valve S070 A 5 B G Electrical entry Body type Body type Base mounted with clips Symbol A G C Grommet Plug lead with light/surge voltage suppressor Coil voltage Power consumption Pressure specification Flow rate 24 VDC 12 VDC
ANA1-01 to 06 ANA1-06: PP How to Order ANA1-01 to 20 A1 03 AN Port size Symbol Port size Connection 01 1 8 02 1 4 03 3 8 04 1 2 Screw-in 06 3 4 1 4 10 1 12 1 1 2 1 14 20 2 Model (One-touch fitting connection) C08 (8 One-touch fittings size) Effective area (mm2) Weight (g) ANA1-C08 11 5 58 16 A B Dimensions (mm) Model One -touch fitting size 8 10 12 C10 (10 One-touch fittings size) One-touch
layout Note 2) (Up to 21 solenoids possible) 20 20 20 stations 20 stations PG: Flat ribbon cable connector (20 pins) PH: Flat ribbon cable connector (10 pins) Connector entry direction Note Symbol Note Symbol Stations Stations 1: Perpendicular connector 2: Lateral connector 02 02 2 stations 2 stations Double wiring Double wiring LOCK FREE FREE 08 04 8 stations 4 stations LOCK 02 02 2 stations
Stations Stations Symbol 02 Symbol 02 2 stations 2 stations Double wiring specifications (1) Double wiring specifications Connector mounting position 10 02 11 02 10 stations 11 stations Mounting position Symbol D 2 stations 2 stations Specified layout (2) (Up to 21 solenoids possible) D side Specified layout (Up to 22 solenoids possible) 20 20 20 stations 20 stations PG: Flat ribbon cable
Series VXA31/32 Dimensions P port Bracket Pilot port J (Spanner flat) Port size P Port size Rc With bracket K 6 7.5 Symbol Model A B C D E F G H J L 29 32 M 14.5 17 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 , , 1 4 3 8 17-3-104 The VX series will be revised shortly.
20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 1 4 3 8 4.1-71 Direct Air Operated 3 Port Valve/Manifold Series VVXA31/32 For Air, Gas, Vacuum and Oil Compatible with a wide variety of fluids.
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
OUT port size Material D side U side 1 2 3 4 5 n Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations Body material C37 Symbol Nil H Seal material FKM FKM 02 : 10 2 stations : 10 stations Stainless steel All IN ports are 3/8. Refer to the "L" dimensions on page 6 regarding the maximum number of stations.
Recommended flow rate Note) (l/min (ANR)) Internal capacity (cm3) 1.7 Mass (g) ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX IN/OUT straight piping 1.7 4.3 ZR Metric size Easy installation
LVD LVQ How to Order Manifold Base LQ1 LVN LLH 2 A 05 02 C TL/TIL Body class Material LQ3 Body class 2 3 4 Manifold PFA Symbol C Symbol 2 3 4 Thread type Thread type Rc NPT Symbol Nil N Base type Port size (port P) A Stacking type Manifold stations Port size 1/4 3/8 1/2 Symbol 02 03 04 Body class 2 3 4 02 2 stations 05 5 stations How to Order Valve LVH 2 0 02 C A Threaded type Body class