Body size 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard Applicable tubing O.D. 1/2 standard Inch size Metric size 3.2 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" With One-touch fittings 4 5/32" 6 3/16" 8 1/4" 10 5/16" 12 3/8" 1/2" Use 1/8" tube. 15-9-97 7 Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow
Table:The NAND Block In In In In Out 1 1 1 1 0 1 1 1 0 1 1 1 0 0 1 1 0 0 0 1 0 0 0 0 1 5 2 PneuAlpha The Logic Function Blocks 5 5.6 The NOR Block (Not OR) The Output comes ON when all the inputs are OFF. The Output remains OFF if any input is ON. If no Input pin is used, the block output is OFF.
Description Material P362010-1 1 NBR, other Diaphragm assembly P362020-13 P362020-13 P362020-2 P362020-2 P362010-2 2 NBR, other Diaphragm assembly P362030-1 P362020-5 P362020-5 P362030-1 3 NBR, other Diaphragm P36202019 P36202019 P36201020 (-1) Note 1) 4 Stainless steel, NBR Valve P36202025 P36202025 5 Brass, NBR Valve P36202009 P36203009 6 Brass, NBR Valve P36203010 P36203010
CRJB 1-90 54 CRJB 1-100 1 CRJB 1-180 67 CRJB 1-190 CRJU05-90 47 05 CRJU05-180 53 With external stopper CRJU 1-90 70 1 CRJU 1-180 81 Note) Above values do not include auto switch weights. 2 Mini-Rotary Actuator Series CRJ Rotating Direction and Rotation Angle The shaft turns clockwise when the A port is pressurized, and counterclockwise when the B port is pressurized.
Process Data Diagnosis items Bit offset Item Note Internal product malfunction Outside of zero-clear range Outside of rated pressure range Upper temperature limit exceeded inside the product 0 OUT1 output 0: OFF 1: ON 1 OUT2 output 0: OFF 1: ON 2 Diagnosis 0: Normal 1: Abnormal 3 to 15 Measured pressure value Unsigned 13 bit Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Item Measured
ITV301l 0.005 to 0.1MPa ITV303l 0.005 to 0.5MPa 1.12-1 1/4, 3/8, 1/2 ITV305l 0.005 to 0.9MPa Series ITV209l Controls vacuum pressure steplessly in proportion to an electric signal.
VCS414 VCS415 VCS 17 1 0 5 1 5 20 1 5 1 0 25 20 1 5 30 25 25 2.
OUT1 5 OUT1 6 7 OUT2 8 OUT2 -N-P 9 OUT2 10 OUT2 11 12 -R-S-T-V 13 14 15 16 17 18 19 20 2 -37No.PS-OMM0002CN-F [F99] <> [F99] [ON] 5 [oFF] [F99] -38No.PS-OMM0002CN-F / ()() 1 "Hi" 1 1 "Lo" 1 1 () 10%0 (1dight ) 1 LoC1 () < -> 5 LoCUnL () / -39No.PS-OMM0002CN-F < -> 5 [UnL] [LoC] 5 [LoC] [UnL] 41/ [UnL] [FAL] 3[LoC] -40No.PS-OMM0002CN-F
Absorbed Energy Max. absorbed energy (J) Collision speed (m/s) Model 1 2 3 4 5 10 20 30 40 50 60 70 80 Soft type RJ0604 0.05 to 1 0.5 H : 0.05 to 2/L : 0.05 to 1 RJ0806H/L 1 H : 0.05 to 2/L : 0.05 to 1 RJ1007H/L 3 H : 0.05 to 2/L : 0.05 to 1 RJ1412H/L 10 H : 0.05 to 2/L : 0.05 to 1 RJ2015H/L 30 H : 0.05 to 1.5/L : 0.05 to 1 RJ2725H/L 70 Short stroke type RJ0805 0.05 to 1 0.5 RJ1006 0.05 to
When 1 digit = 1 kPa, the pressure is given with an increment of Digit (Min. setting unit) 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.
When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.
Note 1) [ ]: Denotes the normal position.
INDEX Precautions for Safety Front matter 1. Product Description 1 1-1 Model 1 1-2 Specifications 1 1-3 Effective Torque 2 1-4 Key (Keyway) Position and Rotation Range 2 2. Internal Construction and Description of Individual Parts 3 2-1 Single Vane Type 3 2-2 Double Vane Type 4 3. Basic Circuit 5 3-1 Circuit Configuration 5 3-2 Preferred Components 5 4.
Flow rate range Output for display unit Note 1) + analog output (1 to 5 V) Output for display unit Note 1) + analog output (4 to 20 mA) 3/8 1/2 3/4 1 2 11 13 19 Port size (inch) 0.4 to 4 l/min 1.8 to 20 l/min 4 to 40 l/min Note 1) Output for the display units of PF2D 300/301 04 20 40 PF2D504 PF2D520 PF2D540 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-
Item Quantity Controller Power supply plug Controller (LECP6###-#-XB55) 1 unit Power supply plug (LEC-D1-1) 1 piece I/O cable (LEC-CN5-#) *1) 1 piece *1) Included in the package only when the I/O cable length is specified. I/O cable Option Teaching box Controller setting kit Teaching box Controller setting kit Actuator cable I/O cable Actuator cable 3.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
3 PA 0.54 13 0.8 4 1/4 (8A) 3/8 (10A) 1/2 (15A) 1/4: 0.42 3/8: 0.40 1/2: 0.49 VCS3 3 0.80 19 0.5 5 1.0 PAX 1.4 33 0.2 7 2.1 50 0.1 10 PB 0.35 8.4 1.0 3 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) 1/4: 0.58 3/8: 0.55 1/2: 0.62 3/4: 0.78 0.60 14 1.0 4 0.85 20 0.7 5 VCS4 1.0 4 1.4 33 0.3 7 2.1 50 0.12 10 Note 1) Refer to page 17-2-42 in model selection regarding port size and orifice size combinations
No.SYJ300-OMU0003 -2- / *3) 1 1.5 *3)1 1 () No.SYJ300-OMU0003 -3- SYJ Series 3 / 1 DC () () () () EXH () () 4 No.SYJ300-OMU0003 SYJ Series 3 / ( ) 1 ( ),COMCOM 2 C-R () C-R Sol.1: DC 3% AC 8% Sol.2: (SSR)AC 1) (C-R) OFF 2) () 1.NPN 3) AC,, , SSR SSR 1) Sol.1: Sol.2: 2) ,1V + 2.NPN 5 No.SYJ300-OMU0003 SYJ Series 3 / 1 -10 1)M5 M3 1/4 0.4~0.5Nm M5 1/6~1/4 1~1.5Nm ()