Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Body size Body size Port size Port size KKA3 S-01 F KKA3 P-01 F Rc1 / 8 Rc1 / 8 KKA3 S-02F 1 / 8 1 / 8 KKA3 P-02F Rc1 / 4 Rc1 / 4 KKA3 S-03 F KKA3 P-03 F Rc3 / 8 Rc3 / 8 KKA4 S-02F KKA4 P-02F Rc1 / 4 Rc1 / 4 KKA4 S-03 F 1 / 4 KKA4 P-03 F 1 / 4 Rc3 / 8 Rc3 / 8 KKA4 S-04 F KKA4 P-04 F Rc1 / 2 Rc1 / 2 KKA6S-03 F KKA6P-03 F Rc3 / 8 Rc3 / 8 KKA6S-04 F KKA6P-04 F 1 / 2 Rc1 / 2 Rc1 / 2 1 / 2 KKA6S
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 2 (Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature: °C/°F], Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 2 (Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature: °C/°F], Bracket
D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting
Caution Plate for Bowl in Imperial Units: psi, °F)
and Caution Plate for Bowl in Imperial Units: psi, °F)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Valve Mounting Direction: Solenoid on the Side Opposite to A Port, Piping: Body Ported, Stations: 20 Stations, A Port Size: -, P R Port Thread: -