SMC Corporation of America
Elite Part Number Search
Search Results "RZQF50-75-60"

REPEATABILITY OUTPUT FLOW 2.8 SCFM at 20 psi / 7 SCFM at 60 psi 0.2 SCFM at 20 psi AIR CONSUMPTION 5 160 F 1/4" NPT ALUMINUM DIE CAST BODY AMBIENT AND FLUID TEMPERATURE AIR PORT MATERIAL WEIGHT 3.1 lbs. 2.65 lbs. NAMUR FEEDBACK SHAFTS HOW TO ORDER For IP5100 Series.

N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.

Specifications Fluid Air 0.15 to 0.7 Operating pressure range (MPa) (0.4 X P + 0.1) to 0.7 P: Operating pressure Pilot pressure range (MPa) Base mounted Max.60 Ambient and fluid temperature (C) Not required (If lubricant is required use turbine oil class no.1 ISOVG32.)

3 40 2 20 1 0 0 30 40 50 60 70 80 75 85 95 105 115 125 135 145 155 165 65 Current (mA) Current (mA) Dimensions PVQ13-L PVQ33 PVQ31 27 30 35 22 27 12 10 20.5 =60.6 5 49 24.7 12 2-1/8" 25 * Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Next, measure the maximum flow to be saturated in the first place, then measure this flow rate at 80%, 60%, 40%, 20% and the upstream and downstream pressure. And then, obtain the sonic conductance C from this maximum flow rate. Besides that, substitute each data of others for the subsonic flow formula to find b, then obtain the critical pressure ratio b from that average.

Panel cut dimensions C4: 4(SMC) N3: 5/32"(SMC) 7 60 97.5 BUS OUT 74.5 70.8 BUS IN PWR L2 4 x M5 hole 4 x 5.5 Note) These figures show the SS5Y5-11SQA-05D-C8. n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7 L2 80 96 112 128 144

Operating temperature range (C) 5 to 60 The shock absorber service life is different from that of the MY1W cylinder depending on operating conditions. Refer to the RB Series Specific Product Precautions for the replacement period. Technical Data 1351 A

Power supply Nil Rc F G (With Rc-G conversion tting) N NPT (With Rc-NPT conversion tting) 46 3-phase 460 VAC (60 Hz) Specications 1 When the ambient temperature or circulating fluid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 14). 2 Use uid in condition below as the circulating uid.

Example) IS10M-6LP 0.1 0.3 0.2 0.4 MPa C q V B Symbol Description Body size 30 40 20 50 60 Nil Set pressure 0.1 to 0.4 MPa 0.1 to 0.6 MPa V V V V V V V V V V a 6 Note 1) range Semi-standard + Lubricator Nil 0.5 m V V V V V V V V V V V V V V V Lead wire w V L Z b 3 m 5 m A D Regulator Air filter length + Applicable model A 11 13 15 17 22 B 74 85 93 97 91 C 61 67 72 75 64 D 28 30 36 44 53 Nil

(mm) Applicable tubing KSH04-M5 KSH04-M6 KSH04-01S KSH06-M5 KSH06-M6 KSH06-01S KSH06-02S KSH08-01S KSH08-02S KSH08-03S KSH10-02S KSH10-03S KSH10-04S KSH12-03S KSH12-04S M5 x 0.8 M6 x 1 36.5 9 12 37 33 8 10.4 16 2.5 4.0 4.0 4 38 37.5 38 39.5 42.5 44 47 48 54 55 57.5 57 60 14 34 33.5 34 35.5 36.5 40 41 41.5 48 48.5 49.5 50.5 52 1 8 M5 x 0.8 M6 x 1 12 2.5 3 4.0 4.0 5.6 5.6 12 8 6 12.8 14 17

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

IDX-OM-W095 1.4 / 1 1.5 () IDFC60/70/80/90 Series 1-6 IDX-OM-W095 2 2.1 IN OUT (ONOFF ) 6-4 6-4 L N PE 3-5 IDFC60/70/80/90 Series 2-1 IDX-OM-W095 () IDFC60/70/80/90 Series 2-2 IDX-OM-W095 3 3.1 50kg IDFC60/70/80/90 Series 3-1 IDX-OM-W095 3.2 3.2.1 (85%) 2045 050 () 2000m 600 mm 600 mm 600 mm 600 mm 600 mm 3.2.2 7 7.3 IDF-AB500 14 1 IDFC60/70/80/90 Series 3-2 IDX-OM-W095 3.2.3 60

AFF20 Phillips screwdriver(+) 0. 75+/-0. 2 Nm AFF30 AFF40 -19- 8. Operation and Adjustment 1) Discharging the product with drain cock Pressurize the inside of the air filter when discharging drain. Drain will not be discharged properly if not pressurized. Drain discharge mechanism is different depending on the bowl assembly.

AM20 Phillips screwdriver(+) 0. 75+/-0. 2 Nm AM30 AM40 -19- 8. Operation and Adjustment 1) Discharging the product with drain cock Pressurize the inside of the air filter when discharging drain. Drain will not be discharged properly if not pressurized. Drain discharge mechanism is different depending on the bowl assembly.

AMD20 Phillips screwdriver(+) 0. 75+/-0. 2 Nm AMD30 AMD40 -19- 8. Operation and Adjustment 1) Discharging the product with drain cock Pressurize the inside of the air filter when discharging drain. Drain will not be discharged properly if not pressurized. Drain discharge mechanism is different depending on the bowl assembly.

P A B C D E G J M N Q R S T U V AMK20 1/81/4 40 133.9 17.5 21 25 21 30 27 22 5.4 8.4 60 2.3 28 AMK30 1/43/8 53 167 21.5 26.5 30 35 26.5 41 35 25 6.5 13 71 2.3 32 AMK40 1/43/81/2 70 212.5 25.5 35.5 38.4 40 35.5 50 52 30 8.5 12.5 88 2.3 39 semi-standard bowl Semi-standard specifications Model Metal bowl No.

bracket With built-in silencer Model K L M N Q R S T U V W VHS20-D 30 25.3 34 5.4 8.4 27 60 40 2.3 3 13 VHS30-D 41 33 43 6.5 10 36.5 71 50 2.3 3 17 VHS40-D 50 44 57 8.5 19 43.5 88 66 2.3 3 21 VHS40-06-D 50 46 59 8.5 19 43.5 88 68 2.3 4 27 VHS50-D 70 60 11 27.5 49.5 113 71 3.2 4 27 -13- Revision history Rev.