D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
MGQ 1 2 3 4 5 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200 300 400 Eccentric distance l (mm) Eccentric distance l (mm) MGG MGC MGTL100 300 300 MGTM100 200 200 P = 0.5 MPa MGF 100 P = 0.5 MPa Larger than 75st Larger than 50st Load mass m (kg) Load mass m (kg) MGZ 40 50 100 25st 50st 30 25, 50st MGT 20 50 40 10 30 5 4 3 20 2 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 30 40 50 100
mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .
Page 30 [F 4] [inP] External input [oFF] Unused Page 31 [F 5] [Eco] Power saving mode [oFF] Unused Page 36 [F 6] [Pin] Security code [oFF] Unused Page 37 [rAn] Select connected sensor [oFF] Unused [F95] Page 38 [Uni] Unit selection function [LPm] L/min [F99] [ini] Reset to the default settings [oFF] Unused Page 40 -23No.PF-OMN0005-E [F 0] Auto-preset This function is capable of calculating
26No.TQ0010298-OM003-A [F 3] Response time Select the response time of the switch output.
PF2D504 0.4 4 PF2D520 1.8 20 PF2D540 4 40 Fluid temperature and pressure PF2D504/520 PF2D540 -21No.PF-OMG0006-F Dimensions (in mm) PF2D504/520 Model A PF2D504 9.53 PF2D520 12.7 -22No.PF-OMG0006-F PF2D540 -23No.PF-OMG0006-F Made to Order Model Indication and How to Order Refer to page 10 for details of model indication and how to order. -24No.PF-OMG0006-F : Select an isometric fitting with
26No.TQ0010298-OM003-B [F 3] Response time Select the response time of the switch output.
S0700 S0700 S0700 Body Ported Base Mounted Blanking plate assembly SS0700-10A-2/SS0700-10A-5 It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve etc. 40.5 40 2 B 4 A Applicable manifold Part no.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed
Simple Specials System Please contact your local sales representative for more details. 2 B *1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) AV 00 20 02 B B 1 D q w e r t y u i o A *1 CE compliant Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V
Simple Specials System Please contact your local sales representative for more details. 2 *1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) AV 00 20 02 B B 1 D q w e r t y u i o A *1 CE compliant Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V V
QJ61BT11N Buffer Buffer memory address Remote input (RX) memory address Remote output (RY) RX F to RX 8 RX 7 to RX 0 RY F to RY 8 RY 7 to RY 0 E0H 160H COM B COM A COM B COM A (IN15 to IN 8) (IN 7 to IN 0) (OUT15 to OUT 8) (OUT 7 to OUT 0) RX1F to RX18 RX17 to RX10 RY1F to RY18 RY17 to RY10 E1H 161H COM D COM C COM D COM C (IN31 to IN24) (IN23 to IN16) (OUT31 to OUT24) (OUT23 to OUT16) RX2F
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.
VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.
Panel mount adapter + Front protective cover ZS-27-D With M3 x 8 l (2 pcs.) 956 Voltage Monitor for PFMV5 Series PFMV3 Specifications Model Series PFMV3 Applicable sensor Series PFMV505(F), PFMV510(F), PFMV530(F) Displayable range 0.70 to 5.10 V: The voltage under 0.7 V is displayed as LLL and that of 5.1 V or more is displayed as HHH.
---t;F=f=='Tjt IN Bracket (Option) N ...'---Ht-t---t-+-H I--i IN o I w c.
Piping Threads with Sealant Caution Mounting Caution AS-F AS-F 1. This product has a stopper for fully close in rotating direction. Excess torque may break the stopper. Table below shows the maximum allowable torque of the knob. 1. If the fitting is tightened with excessive torque, a large amount of sealant will seep out. Remove the excess sealant. TMH ASD 2.