Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model 1000 (35) 200 (7) 500 (17.5) Max. flow capacity l/min (ANR)(SCFM) 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 (2.54) 0.43 (0.95) 0.68 (1.50) Weight kg (lb) Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less (14.5 psi
Station (Max.20) L n 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 310 600 281 571 252 542 223 513 194 484 165 455 136 426 107 397 78 368 L1 L2 L3 L4 L5 49 339 300 590 271 561 242 532 213 503 184 474 155 445 126 416 97 387 68 358 39 329 337.5 625 300 587.5 275 562.5 250 537.5 212.5 500 187.5 475 162.5 450 137.5 425 100 387.5 75 362.5 348 635.5 310.5 598 285.5 573 260.5 548 223 510.5
N Port 2 (A),1 (P) Port size A Model E F G H I J L M P R T U B C D K N O Q S Port 3 (R) VEX5510 VEX5511 160 50 25 10 7 25 173 80 60 98 Center 1 2 3 4 , , 1 1 2 3 4 60 150 79 70 53 13 18 100 2 x M6 Thread depth 9 116.5 , ,1 25 VEX5710 VEX5711 177.5 167.5 84.5 90 60 30 15 7 190.5 54.5 100 60 13 105.5 103.5 18 4 x M6 Thread depth 6 136.5 17 82 1 4 1 4 1,1 1 c Bracket mounting dimensions g Grommet
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 40 60 30 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N Note 2) F Note 3) Thread type Rc NPT G e + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 5) H Note 4) a Without mounting option
Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model 1000 (35) 200 (7) 500 (17.5) Max. flow capacity l/min (ANR)(SCFM) 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 (2.54) 0.43 (0.95) 0.68 (1.50) Weight kg (lb) Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less (14.5 psi
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Broken communicatio wire n monitoring o r time. coming 60 sec. off AL29 Communication error is generated.
n Bore size 12 10 mm x 2 16 12 mm x 2 20 16 mm x 2 25 20 mm x 2 32 25 mm x 2 40 32 mm x 2 50 40 mm x 2 63 45 mm x 2 80 56 mm x 2 100 71 mm x 2 Auto switch Nil Without auto switch (Built-in magnet) For applicable auto switches, refer to the table below.
n: Station Formula 2 257 10 953 7 692 8 779 9 866 3 344 4 431 5 518 6 605 Model L L1 VVPA450 L2 307 394 481 568 655 742 829 916 1003 L3 306 954 414 522 630 738 846 VVPA460 L4 356 464 572 680 788 896 1004 ( ) for VVPA460 1783
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Specifications of options Model Item IP8001-02 52-IP8001-04 Alarm output1, 2 *9 Wiring method 2 wire system Corresponding standard DIN19234/NAMUR Standard Power supply voltage 1028VDC 528VDC Load current 1040mADC *10 (Constant Current) Signal status High (Not Active) R=35010 2.1mADC Signal status Low (Active) *11 0.5mADC or less 1.2mADC Response time 50msec or less Analog output *12,*13 Wiring
Fig. 1 shows an internal alarm circuit of the IP8101-02(Non explosion protected construction). 11: 10mADC or more load current is needed to operate the main circuit of the internal switch, and it should be 40mADC or less to protect the internal resistance circuit. Therefore, use a power supply voltage and load resistance with a load current of 10 to 40mADC when the output is on.
Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. When instructions are given in the Specific Product Precautions, follow these specifications. Caution 1.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
* AKP-LB**(E)-(N)* Without Exhaust Without Exhaust Component Parts No.
Limit of the lead wire tensile force is 50 N. Do not lift or carry the product by holding the lead wire. If the lead wire can move, fix it near the body of the product. Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a lead wire longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.
Rc(PT) Thread F G(PF) N NPT Accessories Options Table: Accessory/Option combinations Available Not available Depending on model L D J T AM150 R AM250 AM350 AM450 Applicable models Accessories /Options C C D -J -R AM550 AM650 AM850 Port size N.C. auto drain N.O. auto drain Accessories 06 3/4B 01 02 03 1/8B Drain guide 1/4B 10 14 20 1/4B 1B 11/2 B Options INOUT reversal 3/8B Element service
Refer to the table below for accessory/option combinations Thread Rc (PT) Table: Accessory/Option combinations Depending on model l Not available Available F G (PF) N NPT Accessories Options C C D -J -R D J T AMD150 R AMD250 AMD350 AMD450 Applicable models Accessories /Options Port size AMD550 AMD650 AMD850 01 B B 06 10 14 1 8 3 4 1B N.C. auto drain N.O. auto drain Drain guide 1/4B IN R