80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?

p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.

p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.

p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.

View A 1 2 3 4 5 6 7 8 Analog output 1 to 5VDC 8 7 6 5 4 to 20mADC 5 20 Analog output [mA] Analog output [V] 1 4 Max. measured flow rate value Real-time flow rate [l/min] Min. measured flow rate value Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l/min] Standard condition Standard condition Basic condition Basic condition Minimum measured Maximum measured

IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part

Maximum allowable load current is 80 mA. Be sure to not exceed 80 mA. 1. Mounting orientation is available either horizontally or vertically. 2. Be sure to hold the main body when handling. 3. Do not drop or strike body. Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads.

Light ass'y for 24 VDC has 3 mA of current leakage.

Hysteresis 0.5 kPa Internal orifice 0.5 0.8 Supply voltage 12 to 24 VDC (Ripple 10% or less) Output type NPN open collector 30 V, 80 mA Indicator light ON: When output is ON.

Brown 3 turns Setting trimmer Part of timer VS VL 24 VDC 3% FS or less Temperature characteristics Black White Internal circuit Internal circuit 30 V Max. 80 mA Max. Timing Chart Blue Suction command OFF T54 ON OFF Suction output 25 mA Max.

My=1 X 9.8(10+30)/1000=0.39 A3=30 M=W(Ln+An)/1000 Corrected value for center position distance of moment An: Table 3 May=1 X 1 X 15.9=15.9 Mymax=15.9 K=1 g=1 a2=0.39/15.9=0.025 Mar=15.9(Same value as May) Calculate allowable static moment Ma (Nm) Ma=K g Mmax Work mounting coeficient K: Fig.3 Allowable moment coeficient g: Graph 2 Max. allowable moment Mmax: Table 4 a2=M / Ma Calculate load

Ma = K Mmax Workpiece mounting coefficient K: Fig. (3) Allowable moment coefficient : Graph (2) Maximum allowable moment Mmax: Table (4) 2 = M/Ma Find the allowable static moment Ma (Nm).

SPECIFICATIONS INPUTS VCC 5 12 VDC Vm 12 VDC DIR TTL, DTL, MOS Compatible Low (0) = Decrease High (1) = Increase CLK TTL, DTL, MOS Compatible 225 Hz Fixed frequency Positive Edge Triggered SPECIFICATIONS SUPPLY VOLTAGE 12 VDC SUPPLY CURRENT Min. 400 mA SELECTABLE STEP RANGE 8 8148 steps STEP RATE 225 PPS OUTPUTS 1 MOTOR 170 mA/coil @ 12 VDC, 36 ohms/coil STEP RATE Motor step rate = Clock

] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.

] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.

the initial period) Solenoid Specifications Option Grommet (G)/(H), L plug connector (L), M plug connector (M), DIN terminal (D) 100, 200, 24, 48, 110, 220 Electrical entry AC 50/60 Hz DC Coil rated voltage (V) 24, 6, 12, 48 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Allowable voltage fluctuation (%) Power consumption (W) [Current mA

DRIVE DRIVE A6 A6 SVON SVON A7 A7 Internal resistance 10 [k] Internal resistance 10 [k] NC NC A8 A8 2 mA or more is needed for the input to be ON. 2 mA or more is needed for the input to be ON.

the initial period) Solenoid Specifications Option Grommet (G)/(H), L plug connector (L), M plug connector (M), DIN terminal (D) 100, 200, 24, 48, 110, 220 Electrical entry AC 50/60 Hz DC Coil rated voltage (V) 24, 6, 12, 48 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Allowable voltage fluctuation (%) Power consumption (W) [Current mA

or less Communication speed 21.6 to 26.4 VDC 100 mA or less Power supply for control Power supply voltage Internal current consumption 22.8 to 26.4 VDC 11 to 25 VDC 100 mA or less Power supply for output Power supply voltage Power supply for Power supply voltage communication Internal current consumption D-sub M12 None Built-in M12 Built-in Communication connector specification Terminating

D-A93 D-M9B D-M9N, D-M9P Type Load voltage Load current range Indicator light Application 24 VDC, 100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA, 5 to 20 mA 2.5 to 40 mA 40 mA or less Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC Reed auto switch Solid state auto switch Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors