Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FX, AS***F 1/2INCH(MISC./OTHER), .33660 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FX, AS***F 1/2INCH(MISC./OTHER), .32340 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, SPL, FLOW CONTROL, SVD, 20.00000 lb
Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L;
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 04 Stations, Passage: 2 (P: Common, EA,EB: Common, Port A,B: Bottom), Port Size: 04 (1/2), Thread: T (NPTF)
Stations: 7 Stations, A, B Port: 04 (Side 1/2), SI Unit: QW (DeviceNet), P, R Port Size: 04 (1/2), P, R Port Location: B (Both Sides), Thread: T (NPTF)
Stations: 5 Stations, A, B Port: 04 (Side 1/2), SI Unit: QW (DeviceNet), P, R Port Size: 04 (1/2), P, R Port Location: U Side, Thread: T (NPTF)
Stations: 5 Stations, A, B Port: 04 (Side 1/2), SI Unit: 0 (w/o SI Unit), P, R Port Size: 04 (1/2), P, R Port Location: D Side, Thread: T (NPTF)
Stations: 8 Stations, A, B Port: 04 (Side 1/2), SI Unit: QW (DeviceNet), P, R Port Size: 04 (1/2), P, R Port Location: B (Both Sides), Thread: T (NPTF)
Stations: 8 Stations, A, B Port: 04 (Side 1/2), SI Unit: 0 (w/o SI Unit), P, R Port Size: 04 (1/2), P, R Port Location: B (Both Sides), Thread: T (NPTF)