Piping: Rc1/4, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: -, Option 1: -, Option 2: -
Piping: Rc1/4, Output: 67 [PNP Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: -, Option 1: -, Option 2: -
Piping: Rc1/4, Output: 27 [NPN Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: -, Option 1: -, Option 2: -
BRACKET, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, 21, ISE70/75 NO SIZE PART, 0.06613 lb
PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .65882 lb
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1.6 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: ISE78G (0 to 16 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE79S (0 to 50 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None
PRESSURE SENSOR FOR GENERAL FLUIDS. F39. 95.00000 lb. PRESSURE SWITCH, PSE100-560.
Dimensions Space saving union elbow: LQ1E-SS B side B (L2) C M A side SMC 6 1 25 H (E) C L1 Class 6 Class 2 to 5 Metric Size Inch Size Model A side B side B C E H L1 L2 M Min. port size Applicable tubing O.D. Applicable body size Model A side B side B C E H L1 L2 M Min. port size Applicable tubing O.D.
The maximum dimension L2 is, as a rule, twice the thread size. (Example) For M3: L2 = 6 mm The maximum dimension L1 is, as a rule, twice the thread size.
The maximum dimension L2 is, as a rule, twice the thread size. (Example) For M3: L2 = 6 mm The maximum dimension L1 is, as a rule, twice the thread size.
The maximum dimension L2 is, as a rule, twice the thread size. (Example) For M3: L2 = 6 mm The maximum dimension L1 is, as a rule, twice the thread size.