SMC Corporation of America
Elite Part Number Search
Search Results "HYDG25R-200"

300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01

How to Order 1F 06 D 200 AS Flow direction symbol on body Flat head screw driver adjustable type Body size 100 200 205 300 400 M5 standard Applicable tubing O.D. 1/8 standard Metric sizes 23 04 06 08 10 12 Inch sizes 1/4 standard 3.2 01 03 05 07 09 11 13 1/8 3/8 standard 4 5/32 1/2 standard 6 3/16 8 1/4 10 5/16 With One-touch fitting 12 3/8 1/2 Use 1/8 tubing.

Bore size (mm) Standard strokes (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting Precautions Caution Mounting and Accessories 1. When mounting, hold the rod cover and apply an appropriate tightening force to the mounting nut, or fasten by applying the appropriate tightening force to the rod cover body.

Symbol Long Stroke (101 to 200 mm) -X10 4 Refer to the table of number of the auto switches mounted below.

DIN terminal Terminal 1 2 + + Pilot Valve Assembly Specifications Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) Electrical entry How to Change Passage State Enclosure Dusttight Lead wire color 100 VAC: Blue, 200 VAC: Red, 24 VDC: Red/Black AC (50/60 Hz) 100, 200, 24, 48, 110, 220, 240 Coil rated voltage (V) 24, 6, 12, 48, 100 DC Allowable voltage fluctuation

VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.

Lead Wire Color (Grommet) Voltage 100 VAC 200 VAC DC Other Color Blue Red Red (+), Black () Gray Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. Ground 4-7-11 12 Series VT317 How to Use DIN Terminal 1.

Cylinder ports should be NAMUR hole pattern. 100/200 V (50/60 Hz) 24 V 15 to +10% of rated voltage Class B or equivalent 5.0 VA/60 Hz, 5.6 VA/50 Hz 2.3 VA (1.5 W)/60 Hz, 3.4 VA (2.1 W) 9/50 Hz 1.8 W Grommet, Grommet terminal, Conduit terminal, DIN terminal Note 1) Use dry-air at low temperature. Note 2) Use turbine oil Class1 (ISO VG32), if lubricated.

L With surge voltage suppressor H 100 VAC J 110 VAC K 200 VAC L 230 VAC M Conduit terminal 24 VDC With surge voltage suppressor N 100 VAC P 110 VAC Q 200 VAC R 230 VAC S Conduit 24 VDC With surge voltage suppressor T 100 VAC U 110 VAC V 200 VAC W 230 VAC Faston terminal Y 24 VDC Z Other voltages For other special options, refer to pages 20 and 21. 24 VAC 48 VAC 220 VAC 240 VAC 12 VDC Special

A C (+) White Reset (Vacuum suspension) B AC type Lead wire colors 100 VAC, 200 VAC Set (Vacuum generation) Yellow Yellow A 3. Suspension of operation for long periods of time Please use caution as detailed below when the vacuum equipment is turned off for periods in excess of 6 hours. Be sure to turn off the pressure supply to the vacuum equipment.

Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 230/50/60/1 Flow Rate: 43 LPM , 43 LPM, Max Pressure: 2.9 PSIG / 80 in H20 / 200 mbar , 2.9 PSIG / 80 in H20 / 200 mbar, Max Vacuum: 5.9 in HgV / -200 mbar , 5.9 in HgV / -200 mbar, Voltage (60 Hz): 230, Voltage (50 Hz): 230, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.15

Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 230/50/60/1 Flow Rate: 43 LPM , 43 LPM, Max Pressure: 2.9 PSIG / 80 in H20 / 200 mbar , 2.9 PSIG / 80 in H20 / 200 mbar, Max Vacuum: 5.9 in HgV / -200 mbar , 5.9 in HgV / -200 mbar, Voltage (60 Hz): 230, Voltage (50 Hz): 230, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.15

Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter Air Source Warning (1) Use clean air.

DIN terminal Terminal 1 2 + + Pilot Valve Assembly Specifications Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) How to Change Passage State Electrical entry Enclosure Lead wire color Dusttight 100 VAC: Blue, 200 VAC: Red, 24 VDC: Red/Black 100, 200, 110, 220, 240 DC AC (50/60 Hz) Coil rated voltage (V) 24, 12 Allowable voltage fluctuation 15 to +10% of rated

L M5 x 60 L 165 180 200 60 CNS CLQB40-10D CLQB100-10D M5 x 75 L M8 x 90 L M10 x 115 L x 65 L 75 90 115 65 -15D -15D x 80 L x 95 L x 120 L x 70 L 80 95 120 70 CLS -20D -20D x 85 L x 100 L x 125 L x 75 L 85 100 125 75 -25D -25D x 90 L x 105 L x 130 L x 80 L 90 105 130 80 8.5 CLQ -30D -30D x 95 L x 110 L x 135 L x 85 L 95 110 135 85 -35D -35D 8.5 15.5 16.5 x 100 L x 115 L x 140 L x 90 L 100

Seal kit includes a grease pack (125 to 160: 40 g, 180, 200: 50 g, 250: 60 g). Order with the following part number when only the grease pack is needed.

20,000 (Refer to page 71 for limit according to work load and duty ratio.)o0.021650/20Ball screwLinear guide5 to 4090 or less (No condensation)200 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)6517528725Non-magnetizing lock1977.924 VDC 010%

20,000 (Refer to page 71 for limit according to work load and duty ratio.)o0.021650/20Ball screwLinear guide5 to 4090 or less (No condensation)200 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)6517528725Non-magnetizing lock1977.924 VDC 010%

) VEX 0.25 0.25 0.20 0.20 AMR 0.15 0.15 ITV 0.10 0.10 IC 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 VBA Flow rate (/min (ANR)) Flow rate (/min (ANR)) VE VY1 G Pressure Characteristics PPA Inlet pressure: 2.0 MPa Outlet pressure: 0.8 MPa Flow rate: 60 /min (ANR) Inlet pressure: 2.0 MPa Outlet pressure: 0.3 MPa Flow rate: 60 /min (ANR) AL

Piston B Switching Pressure (Open Closed) 0.5 Outlet pressure (MPa) 0.4 0.3 0.2 Type Y DIN terminal 0.1 0 0.6 0.1 0.2 0.3 0.4 0.5 0.7 0.8 0.9 1.0 Inlet pressure (MPa) Needle Valve Flow Characteristics Inlet pressure 0.5 MPa JIS Symbol 2000 1800 AV5000 1600 Air flow rate (/min (ANR)) 1400 2 1(P) 2(A) AV4000 1200 1 1000 800 AV3000 3(R) 600 AV2000 400 Accessory/Pressure Gauge 200 0 Pressure