CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 + 0.036 0 8 8 + 0.4 + 0.1 41 + 0.4 + 0.1 48 + 0.5 + 0.1 48 + 0.5 + 0.1 56 (29.3) (33.1) (40.4) (49.2) 31 37 38.5 42.5 5.5 5.5 6.6 6.6 42 48 53 60 10 10 10 10 10 10 10 10 20 25 32 40 + 0.036 0 + 0.036 0 + 0.043 0 + 0.043 0 25 30 35 40 5.5 5.5 6.6 6.6 36 43 50 58 20 25 32 40 10 10 + 0.043 0 12 12 + 0.043
L D d m t d H B C C type 10 for shaft 41.6 50.6 9.6 13.4 36.2 44.2 1.55 2.05 1.15 1.15 M14 x 1.5 M18 x 1.5 8 11 22 27 25.4 31.2 IY-G04 IY-G05 C type 14 for shaft 10 14 -0.040 -0.076 -0.050 -0.093 14 Series RLQ Simple Joint/32 to 63 A type mounting bracket 2-D T1 T2 M W V U F B E (mm) Joint and mounting bracket (A type, B type) part no.
m (kg) 25 20 20 0.1 10 50 50 100 200 1 10 100 200 Eccentric distance l (mm) Eccentric distance l (mm) MLGPL32 to 100 23 50mm stroke or less V = 400mm/s 24 Over 50mm stroke V = 400mm/s 100 100 100 80 100 80 63 63 10 Load weight m (kg) 50 50 10 40 40 32 1 32 2 10 100 200 0.3 10 50 50 100 200 Eccentric distance l (mm) Eccentric distance l (mm) Features 10 Series MLGP Horizontal Mounting Slide
m (kg) 25 20 20 0.1 10 50 50 100 200 1 10 100 200 Eccentric distance l (mm) Eccentric distance l (mm) MLGPL32 to 100 23 50mm stroke or less V = 400mm/s 24 Over 50mm stroke V = 400mm/s 100 100 100 80 100 80 63 63 10 Load weight m (kg) 50 50 10 40 40 32 1 32 2 10 100 200 0.3 10 50 50 100 200 Eccentric distance l (mm) Eccentric distance l (mm) Features 10 Series MLGP Horizontal Mounting Slide
Refer to pages 12-10-4 to 12-10-5 for the details on effective holding force and allowable overhanging distance. Misc. D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !
Refer to pages 12-10-4 to 12-10-5 for the details on effective holding force and allowable overhanging distance. Misc. D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !
22.5 15.5 9.6 17.5 10 2.5 25.5 24.5 13.7 15.4 14.29 7 18 2.7 8 9 18 5 10 19 3.2 10 20 32 12 20 28 16 23 33 59 28 36 62 10-32UNF 12.7 2.3 9.3 15.6 1 16 22 11.11 5 32 23 16 1 8 1 4 10.4 10 18 3 26 25 14.29 KQ2L05-32 10-32UNF 20 22 2.3 11.11 11.4 10 19.5 3 16 1 8 1 4 22.5 26.5 15.1 23.5 27.5 29.5 24.5 28.5 30.5 26.5 29.5 31.5 35.5 31.5 33.5 37.5 24 26 16.5 3.5 14.29 10-32UNF 2.3 18.1 13.6
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.
N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.
Metric size 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
(between case and cable) Ambient temperature -10 to 60 C Enclosure IEC 60529 criteria IP67, JISC0920 watertight construction Standard CE/UKCA marked -24No.D-S-OMJ0004-G Dimensions D-M9B(W/E)/D-M9N(W/E)/D-M9P(W/E) D-M9B(W/E)V/D-M9N(W/E)V/D-M9P(W/E)V -25No.D-S-OMJ0004-G Pre-wired connector A B D-M9### PC D-M9###DPC -26No.D-S-OMJ0004-G Revision history A: Standardize each contents for series
Valve series Power consumption SY3000/5000/7000/9000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) SYJ3000/5000/7000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) VQZ1000/2000/3000 Standard: 1.0 W (approx. 42 mA) Low wattage: 0.5 W (approx. 21 mA) Refer to "Wiring of the branch cable and connector for connecting load" on
.: 3.5 to 7 (Reference) 0.5 mm2 2-core and 3-core wire equivalent to JIS C 3306. 0 V 10 to 20 ms 2.9 W Ground nut Tightening torque 1.65 to 2.5 Nm Washer Power-saving Tightening screw Tightening torque 0.3 to 0.4 Nm 0.6 W 0 W AC circuit Grommet (Rubber) Housing Lead wire color DIN connector 1 LED Blue (100 VAC), Red (200 VAC) (Voltage symbol) Refer to the following table (Position for light
SP ZCUK (mm) W B D-A9, D-A9V D-M9, D-M9W D-M9V, D-M9WV Bore size (mm) AMJ B A W 16.5 A B W A 10 16 20 25 32 0.5 7.5 2.5 7.5 3 12.5 16.5 1.5 (1) AMV 0 8 1.5 8 20 4 16 20 2 (0.5) 2 10 0 10 24 6 20 24 4 (1.5) AEP 3.5 11.5 1.5 11.5 26.5 7 22.5 26.5 5.5 (3) 4.5 12.5 2.5 12.5 27.5 8 23.5 27.5 6.5 (4) HEP Note 1) Figures in the table above are used as a reference when mounting the auto switches
MHR2-10/MDHR2-10 MHR2-10/MDHR2-10 20 20 Pressure 0.6 MPa Pressure Gripping force (N) Gripping force (N) 15 15 0.6 MPa 0.5 MPa MHZ 0.5 MPa 10 10 0.4 MPa 0.4 MPa MHF External grip 0.3 MPa 0.3 MPa 5 5 MHL 0.2 MPa 0.2 MPa MHR 0 10 20 30 40 50 0 10 20 30 40 50 Gripping point L (mm) Gripping point L (mm) MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
Internal hold External hold MHR2-10/MDHR2-10 MHR2-10/MDHR2-10 20 20 Pressure 0.6MPa Pressure 15 15 Holding force (N) 0.6MPa Holding force (N) 0.5MPa 0.5MPa External hold 10 10 0.4MPa 0.4MPa 0.3MPa 0.3MPa 5 5 0.2MPa 0.2MPa 0 10 20 30 40 50 0 10 20 30 40 50 L L Holding point L (mm) Holding point L (mm) MHR2-15/MDHR2-15 MHR2-15/MDHR2-15 Pressure 0.6MPa 30 30 Internal hold Pressure 0.6MPa 0.5MPa
L k Imaginary stroke L' = (Stroke) + k + L k: Distance between the center and end of the plate 6 (Example) q When using CXSJM6-10 and L = 15 mm: Imaginary stroke L' = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 6 ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 w When using CXSJL25-50 and L = 10 mm: Imaginary stroke L' = 50 + 6 + 15 = 71
10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
Hyrodless Monosashi-kun (with Stroke Adjustment Unit, X417) 31 Chapter 9: Construction / Parts List 32 Chapter 10: Cushion Capacity 10-1. Cushion Selection 33 10-2. Absorbing Capacity of Air Cushion, Stroke Adjustment Unit 34 10-3. Adjusting Method 35 Chapter 11: Stopping Operation 11-1. Over run 36 11-2.