(full span), GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .20383 lb, ModelPressure range (1)Indication unitConnection threadNote MPaG46-2-01/020 to 0.2MPaR 1 8, 1 4?
(full span), GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .23540 lb, ModelPressure range (1)Indication unitConnection threadNote MPaG46-2-01/020 to 0.2MPaR 1 8, 1 4?
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full
(full span), GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .25419 lb, ModelPressure range (1)Indication unitConnection threadNote MPaG46-2-01/020 to 0.2MPaR 1 8, 1 4?
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: 01 (Rc1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment
(16 outputs) 0 1 Digital output unit EX600-DYF (16 outputs) 0 1 EX600-DME (8 inputs/8 outputs) 1 1 Digital I/O unit EX600-DMF (8 inputs/8 outputs) 1 1 Analog input Unit EX600-AXA 2 (1 word / 1 channel) 0 (2 channels) (2 channels) 0 2 Analog output Unit EX600-AYA (1 word / 1 channel) Analog I/O Unit EX600-AMB 2 2 (2/2 channels) (1 word / 1 channel) (1 word /1 channel) Note) 1 word is equivalent
PB10 Speed integral compensation] _ _ _ 2 Auto tuning mode 2 [Pr. PB07 Model loop gain] [Pr. PB08 Position loop gain] [Pr. PB09 Speed loop gain] [Pr. PB10 Speed integral compensation] _ _ _ 3 Manual mode _ _ _ 4 2 gain adjustment [Pr. PB08 Position loop gain] [Pr. PB09 Speed loop gain] [Pr. PB10 Speed integral compensation] mode 2 The driver is set to "auto tuning mode 1" as shipped.
size 01 B 1 8 B 1 4 B 3 8 04 B 1 2 06 B AFF 1 Standard 11 2 Standard Nil Rc Thread type 02 03 JIS Symbol AME AM F G N NPT P . 14-20-57 3 4 1B Misc. 10 14 1 B 1 2 20 2B Caution Note) Refer to How to Order Bowl Assembly on page 14-20-59.
Flange JIS B 2 3 inch Mounting orientation is upward. To booster lube From booster lube To booster lube From booster lube A B 63 63 80 85 90 100 C Port size Rc INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model 1 4 3 8 15 15 15 20 22 22 141 164.5 170 180 230 251 , , 1 4 3 8 1 2 B C D E F Port size Rc Part no.
Model AME250 AME350 AME450 AME550 AME650 AME850 AME150 12000 (1) 12000 Rated flow (l/min (ANR)) 500 1000 2000 3500 6000 200 Port size (Nominal size B) 1 8 1 4 3 8 , , , , , , , , , , 1 4 3 8 1 2 3 8 1 2 3 4 1 2 3 4 1 1 3 4 1 1, 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.
Circuit (of class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL1310 class 2 power supply unit or UL1585 class 2 transformer. The product is a approved product only if it has a mark on the body.
Specification NOTE The direct current power supply to be used should be UL approved as follows : Circuit (of class 2) which is of maximum 30Vrms (42.4V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The Pressure switch is a approved product only if it has a mark on the body.
10 10 12 12 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) With One-touch ttings Example) AS2002FS-04-X214 With indicator 10Clean Series 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing.
Delivery Pressure: 01 [1 to 10 psig (0.007 to 0.07 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: M [10 μin. (0.25 μm)], Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: MV4 (1/4 Inch Face Seal, Male), Gauge Port, Inlet: No
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
Please contact us for the latest version.sales@ocaire.com, GAUGE, SRH PRESSURE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .33069 lb, ModelPressure range (1)Indication unitConnection threadNote MPaG46-7-01/020 to 0.7MPaR 1 8, 1 4?
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full